If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA DO 2000 DISSOLVED OXYGEN CONTROLLERTRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA DO 2000 DISSOLVED OXYGEN CONTROLLERTRANSMITTER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA DO 2000 DISSOLVED OXYGEN CONTROLLERTRANSMITTER.
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA DO 2000 DISSOLVED OXYGEN CONTROLLERTRANSMITTER
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
lpha-DO2000
Dissolved Oxygen Controller/Transmitter
Technology Made Easy . . .
68X216835 Rev 0 05/04
Preface This manual serves to explain the use of the lpha DO 2000 Series. The manual functions in two ways, firstly as a step by step guide to help the user operate the instrument, and secondly as a handy reference guide. This instruction manual is written to cover as many anticipated applications of the lpha DO 2000 as possible. If you have any doubts concerning the use of the instrument, please do not hesitate to contact the nearest Eutech Instruments Authorised Distributor. [. . . ] Take the probe out of the zero oxygen solution, rinse in clean water, dry it and then calibrate in air. The "CAL" indicator flashes at the top. When the reading is stable, "READY" annunciator comes on. Press the ENT key to accept the high-level calibration (100%) and the status of the probe is displayed. Note: If the displayed value is not within ±50% of the high point value, the controller will not accept the high-level calibration and retains the previous calibration values. Note: If there is a calibration error, the controller displays "CAL ERR" and exits to the measurement mode (for direct access calibration mode) or to the setup menu (for calibration mode accessed via Setup mode). After calibration, the controller automatically displays the condition of the probe in the upper display and the temperature in the lower display (for Two-Point calibration only). You can view these values without calibration --- see Section 5. 4 for instruction. The probe condition is redetermined after each calibration. Press the ENT key (or CAL key) to return to the measurement mode (for direct access calibration mode) or to the setup menu (for calibration mode accessed via Setup mode). Note: When calibrating with manual temperature compensation, the controller automatically changes from the preset process temperature to the calibration temperature. After leaving the Calibration mode, the controller switches back to process temperature (for setting the calibration temperature and the process temperature, see Section 6. 3)
5. 4
View actual probe condition
MEAS
89. 5
%
CAL
24. 5 ATC
000
CD . C
ENT
1. 00
24. 5
ENT
MEAS
o
C
CAL
89. 5
%
C 24. 5 ATC
o
1. While in Measurement mode press the CAL key. The display will prompt you to enter a security code. Leave the security code at "000" (view only mode). The display shows the actual probe condition. Press the ENT key to return to the Measurement mode.
16
Instruction manual
lpha DO 2000
6
6. 1
SETUP MODE
Enter Setup mode
1. While in Measurement mode press the ENT key. The display prompts you to enter the security code. Set the security code with or key to: - "SCD 22" if you want to change parameter settings - "SCD 000" if you want to view only parameter settings (view only mode) 3. Press the ENT key
ME AS
In the Setup mode the transmitter can be configured to your individual requirements.
13. 0
ENTER ENT
%
°C
ENT ENTER
SE TUP
HOLD
OFS
ENT
Offset Pressure compensation settings
SE TUP
HOLD
ENT
Temperature settings see section 6. 3 Relay A (set point 1) settings see section 6. 4
SE TUP
HOLD
ENT
SE TUP
HOLD
ENT
Relay B (set point 2) settings see section 6. 4
SE TUP
HOLD
ENT
Controller settings see section 6. 5
SE TUP
HOLD
ENT
Current output 1 settings see section 6. 6 Current output 2 settings see section 6. 7
SE TUP
HOLD
ENT
SE TUP
HOLD
ENT
Wash contact settings see section 6. 8
SE TUP
HOLD
ENT
Unit settings see section 6. 9
SE TUP
HOLD
ENT
DO
Calibration see section 5
Note: Note: to exit Setup mode at any time press the and key simultaneously (escape). The transmitter returns to the Measurement mode.
17
Instruction manual
lpha DO 2000
6. 2
Offset, Salinity and Pressure compensation (OFS) sub-function
This mode allows you to change the offset parameter to make reading corrections without removing the electrode from the control system. [. . . ] Please follow the guidelines below before shipment.
10. 4
Guidelines for returning unit for repair
Use the original packaging material if possible when shipping the unit for repair. Otherwise wrap it with bubble pack and use a corrugated box for better protection. Include a brief description of any faults suspected for the convenience of Customer Service Dept. , if possible.
10. 5
Maintenance and Cleaning
Maintenance The lpha DO 2000 contains no user repairable components. Please contact Eutech Instruments or its distributor if there is any problem with the unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA DO 2000 DISSOLVED OXYGEN CONTROLLERTRANSMITTER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.