If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH 2000 PHORP CONTROLLERTRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA PH 2000 PHORP CONTROLLERTRANSMITTER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA PH 2000 PHORP CONTROLLERTRANSMITTER.
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
pH and ORP Controller/Transmitter
lpha-pH2000
Technology Made Easy . . .
68X216830 rev0 06/02
Preface
This manual serves to explain the use of the lpha-pH2000 series pH/ORP controller/transmitter. The manual functions in two ways, firstly as a step by step guide to help the user operate the instrument. Secondly, it serves as a handy reference guide. This instruction manual is written to cover as many anticipated applications of the lpha-pH2000 pH/ORP controller/transmitter. [. . . ] ATC disabled (ATC OFF): For manual temperature compensation you can set the process and calibration temperatures. This allows calibration at a temperature other than the process temperature. Example: setting a calibration temperature of 25°C lets you calibrate using standard buffer solutions at 25°C, even if your process temperature is different from 25°C. 4. Setting the process temperature: press the or key to adjust the process temperature (upper value, setting range: 9. 9 to 125°C / 15 to 257 °F). Press the ENTER key to confirm process temperature. Setting calibration temperature: press the or key to adjust the calibration temperature (upper value, setting range: 9. 9 to 125°C / 15 to 257 °F). Press the ENTER key to confirm the calibration temperature. Setting temperature offset: The display shows the current temperature offset (upper value) and the temperature currently measured (lower value). Compare the current temperature displayed on the transmitter to a thermometer known to be accurate. Note down the correct temperature value. Press the or key to adjust the lower value. The upper number indicates the offset value. You can offset the temperature by up to ±10°C/±18°F. Press the ENTER key to confirm your setting. Continue with additional Setup procedures, or return to the Measurement mode by pressing the s and t keys (escape) simultaneously.
25
6. 4 Control Relay A/Control Relay B (SP1/SP2) sub-function The SP1 sub-function determines the operating parameters for Relay A; while SP2 defines the operating parameters for Relay B. Since these groups have the same set-up parameters, they are described together.
SETUP
HOLD
SETUP
HOLD
PH
SETUP
HOLD
SETUP
HOLD
SETUP
HOLD
hi
SETUP
HOLD
SETUP
HOLD
1. Select the "SP1" (Relay A) or "SP2" (Relay B) sub-function, then press the ENTER key. Setting set point value: press or key to enter the value for set point 1 (set point 2) at which your controller will activate. Press the ENTER key to confirm your setting. Selecting relay function: press the or key to select the desired relay function ("LO"= low or "HI"= high). Press the ENTER key to confirm your selection. Note: This parameter lets you choose the relay function. [. . . ] will determine if product problem is due to deviations or customer abuse. Out of warranty products will be repaired on a charge basis.
10. 2
Packaging
The instrument is packaged in a corrugated box with a warranty card, instruction manual and the following accessories: · Plug, nylon, black, 2 pcs · PG 13. 5, cable gland, 3 pcs · Connectors, 1 each of 3-way (5. 08 mm), 9-way(5. 08 mm), 13-way (3. 5 mm), 8-way (3. 5 mm) and 3-way (3. 5 mm)
10. 3
Return of Goods
Authorisation must be obtained from Eutech Instruments' Customer Service Dept. to issue a RGA (Return of Goods Authorisation) number before returning items for any reason. When applying for authorisation, please include data requiring the reason of return. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH 2000 PHORP CONTROLLERTRANSMITTER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH 2000 PHORP CONTROLLERTRANSMITTER will begin.