Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH 500 PHORP 2-WIRE TRANSMITTER (REVISION 1). We hope that this EUTECH INSTRUMENTS ALPHA PH 500 PHORP 2-WIRE TRANSMITTER (REVISION 1) user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA PH 500 PHORP 2-WIRE TRANSMITTER (REVISION 1).
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
pH 500 LCD Transmitter
2-wire pH/ORP Transmitter with Display
Technology Made Easy . . .
68X216829 03/02 version 1
Preface
This manual serves to explain the use of the pH 500 transmitter. It functions in two ways, firstly as a step by step guide to help you to operate the transmitter. Secondly, it serves as a handy reference guide. It is written to cover as many anticipated applications of the transmitter as possible. [. . . ] In such cases, an on-line Offset adjustment is offered. Upper display shows amount of offset, in terms of pH; lower display shows current measured pH value. Use or keys to introduce offset to pH readings. As the lower measured reading changes, upper display records the amount of offset. Maximum of ± 2. 00 pH offset is allowed. Press both or keys together to return to ` MEAS ` mode.
SETUP
HOLD
2.
SETUP
READY
HOLD
.
.
pH
pH
3.
11
5. 2
Output Range Setting
SETUP
HOLD
Output of pH 500 transmitter is via the 2-wire power supply loop. Both the 4 mA and 20 mA output can be assigned to specific pH or ORP values, for a more refined output. Press ENT key and use or keys to scroll till LCD displays `r n g '. Upper display shows pH value, `0. 00' (or 1000 mV) while lower display shows `r 4. 0'. Assign pH or ORP value to 4 mA output current. Upper display shows pH value, '14. 00' (or 1000 mV) while lower display shows `r 20. 0'.
2.
3. 5.
Assign pH or ORP value to 20 mA output current. Use or keys to change pH or ORP value. Press ENT key.
o
C'.
6.
Press
and
keys together, to return to MEAS mode.
The transmitter will now compensate pH readings for the manually set temperature (values taken from P oC).
SETUP
HOLD
SETUP
HOLD
SETUP
HOLD
SETUP
HOLD
SETUP
.
.
HOLD
ATC
.
SETUP
HOLD
.
Temperature Compensation Setting Chart alpha pH 500 Transmitter
14
5. 4
SETUP
HOLD
HOLD Current Setting
When Transmitter is in CAL or SETUP modes, it automatically goes into a `HOLD' mode. To indicate Transmitter is in `HOLD' mode, output current can be set to 22 mA output by activating the `HLD On'.
1.
SETUP
HOLD
Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `HLd' in the lower display. Press ENT again.
Upper display now shows `HLd'. Lower display will show either `OFF' or `On'. Use or keys to toggle between `On' of `OFF'. Press ENT to accept selection.
2.
SETUP
HOLD
3.
measured value.
Press
and
keys together, to return to MEAS mode.
NOTE: If `HLd' is set to `OFF', then current output will be equivalent to last
5. 5
SETUP
HOLD
Out-of-Range Current Setting
If pH or ORP readings exceed the scale, LCD displays `Or' (over-range), or `Ur' (under-range). Transmitter current output can be set to 3. 8 mA to indicate Out-of Range situation.
1.
SETUP
HOLD
Press ENT key and use or keys to scroll till LCD displays `SEt' in the upper display; and `org' in the lower display. Press ENT again.
Upper display now shows `org'. Lower display will show either `OFF' or `On'. [. . . ] Protein cleaning solution for pH electrode Storage solution for pH electrode
Note: pH buffer solutions (480-ml bottle) have ±0. 01 pH accuracy at 25 °C. Sachets are individually sealed, single use pouch containing 20 ml of fresh, contamination free calibration solution. pH buffer sachets have ±0. 01 pH accuracy at 25°C and conductivity sachets have ±1% accuracy at 25°C.
22
OAKTON INSTRUMENTS
Replacement Transmitter and Transmitter accessories
Ordering Code No. Item Alpha pH/ORP 2-wire LCD Transmitter Combination pH electrode with 5m cable Combination pH electrode with PMP and 5m cable Combination pH electrode with PT 100, PMP and 5m cable Combination pH electrode, submersible, with 5m cable Combination Gold ORP electrode with PMP and 5m cable Combination Platinum ORP electrode with PMP and 5m cable
Calibration Solutions
Ordering Code No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH 500 PHORP 2-WIRE TRANSMITTER (REVISION 1)
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH 500 PHORP 2-WIRE TRANSMITTER (REVISION 1) will begin.