User manual EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE. We hope that this EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE.


Mode d'emploi EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE
Download
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL ECFP21A1A1 Differential pH Sensor 1 ½ Inch NPT Mounting Threads Technology Made Easy . . . 68X216866 Rev 0 10/04 Preface This instruction manual serves to explain the use of the ECFP21A1A1 1½ inch pH sensor and is written to cover as many applications as possible. Please do not hesitate to contact Eutech Instruments or an authorized representative with questions or concerns. The information presented in this instruction manual is subject to change without notice as improvements are made, and does not represent any commitment whatsoever on the part of Eutech Instruments. Eutech Instruments cannot accept any responsibility for damage or malfunction of the sensor due to improper use. [. . . ] Calibrate: Power the Alpha pH2000D controller. Remove the protective cap from the sensor head and make sure moisture is present and that the salt bridge has not dried out. If the protective cap is dry, the sensor should be hydrated in tap water for at least 1 hour prior to calibration. Calibrate the pH sensor as explained in the Alpha pH2000D manual. It is recommended to use a 2-point buffer calibration on installation of the sensor. Subsequent calibrations should be scheduled based on process demands. If measurement response time is slow or if the sensor will not calibrate, refer to Section 4 for maintenance, refurbishment and troubleshooting suggestions. 2. Mount: a. Apply Teflon® tape to the sensor body threads. Insert the sensor into the tee and slowly turn clockwise until secure. Tighten the sensor with a wrench until snug to prevent leaking. Be sure the pipe remains full when the sensors are installed. 9 Instruction manuals ECFP21A1A1 3. 2. 2. Immersion Mounting For immersion mounting applications the sensor is connected to a 1½ inch extension pipe to protect the cable from damage and to reduce the possibility of leaks that may damage the sensor. Figure 3. 5: Immersion mounting assembly 10 Instruction manuals ECFP21A1A1 Detailed Insertion Mount Installation Instructions 1. Route the sensor cable through the 1. 5 inch extension pipe. Apply Teflon® tape to the sensor threads. Attach the sensor to the 1. 5 inch NPT coupling by turning the sensor in a clockwise direction until secure. Either route the cable directly to the Alpha pH2000D or splice the wires in a junction box and use an extension cable. Insert the cable into the Alpha pH2000D controller through a watertight cord grip. Conduit holes are provided for the cord grip on the bottom of the Alpha pH2000D controller. Connect the sensor wires into the Alpha pH2000D sensor terminal block as shown in the Alpha pH2000D manual. Remove the protective cap from the sensor head and make sure moisture is present and that the salt bridge has not dried out. If the protective cap is dry, the sensor should be hydrated in tap water for at least 1 hour prior to calibration. Calibrate the pH sensor as explained in the Alpha pH2000D manual. [. . . ] If on the second attempt the offset does not meet specification, replace the sensor. pH Span Test If the RED and GREEN wires have already been disconnected to run the offset test, skip step 1. Disconnect the RED and GREEN sensor wires from the analyzer terminal block while leaving the other wires connected. Connect the (+) lead of a millivolt meter to the RED wire and the (-) lead of the millivolt meter to the GREEN wire. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH DIFFERENTIAL PROBE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag