User manual EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER.


Mode d'emploi EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER
Download
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER

Detailed instructions for use are in the User's Guide.

[. . . ] patents 5, 198, 093, D334, 208 and D346, 753. ionplus electrodes and Optimum Results solutions are protected by U. S. patent 5, 830, 338. ROSS Ultra electrodes are protected by U. S. patent 6, 793, 787. ORP standard is protected by U. S. patent 7, 276, 142. © 2009 Thermo Fisher Scientific Inc. [. . . ] LCD shows `READY' annunciator when the reading is stable. Press ENT key (or CAL key) to confirm the reading. The pH Monitor re-calculates electrode properties based on the calibration. The new slope (in mV) is shown in the upper display and pH reading at 0mV (pH7. 00 ± offset) is shown in the lower display. Press ENT key to exit from the calibration. The pH Monitor reverts to pH measurement mode. · · To exit from pH calibration mode without confirming calibration, press and keys together. When confirming the buffer measurement, if measured pH value is not within ±1. 00pH from selected buffer value, the electrode annunciator blinks and ERR indicator appears in the display. This error can also occur if non-standard buffers are used or the electrode has worn out. If this happens, press both and keys together to restart the calibration beginning from Step1. · When calibrating with manual temperature compensation, the meter automatically changes from the preset `process temperature' to the `calibration temperature'. After leaving the calibration mode, the pH Monitor reverts back to `process temperature'. 4. 3. 2 For NIST Buffer Make sure that the pH Monitor is set to accept NIST standard buffer in the Setup mode. (Refer Section 5. 4 for Buffer Selection Settings) The factory default is USA standard. Press ENT key (or CAL key) to confirm the reading. The pH Monitor re-calculates electrode properties based on the calibration. The new slope (in mV) is shown in the upper display and pH reading at 0mV (pH7. 00 ± offset) is shown in the lower display. Press ENT key to exit from the calibration. The pH Monitor reverts to pH measurement mode. 3 4 5 NOTES: · · To exit from pH calibration mode without confirming calibration, press and keys together When confirming the buffer measurement, if the measured pH value is not within ±1. 00pH from selected buffer value, the electrode annunciator blinks and ERR indicator appears in the display. This error can also occur if non-standard buffers are used or the electrode has worn out. If this happens, press both and keys together to restart the calibration beginning from Step1 When calibrating with manual temperature compensation, the meter automatically changes from the preset process temperature to the calibration temperature. After leaving the calibration mode, the pH Monitor reverts back to process temperature. 4. 4 ORP Calibration The pH Monitor allows a single point ORP calibration. ORP calibration process is available only when the measurement mode is set to ORP. (Refer Section 5. 5 for switching measurement modes). - 21 - 1 CAL CAL 2 mV READY HOLD 3 CAL mV 4 MEAS R. mV ENT HOLD READY HOLD ENT READY °C ATC 1 2 From ORP measurement mode press CAL key to enter calibration mode as described in section 4. 2. Place the electrode in a standard ORP solution of known OPR value. [. . . ] Press ENT key to quit from electrode properties screen. The pH Monitor reverts to CdAt screen. 2 Press or key to access other setup screens or press and key simultaneously (escape) to return to measurement mode. - 31 - 6 (a) pH TECHNICAL SPECIFICATIONS General Specification Measuring Range Resolution Accuracy (b) mV Measuring Range Resolution Accuracy (c) Temperature Measuring range Resolution -1000 to 1000 mV 1 mV ± 1 mV -10. 0 to +125. 0 oC or +14. 0 to +257 oF 0. 1 oC 0. 1 oF (Resolution is 0. 1 oF up to 199. 9 oF and 1 oF for 200 oF and above) ±0. 5 oC ±1. 0 oF 2 wire / 3 wire - Pt100 or Pt1000 (Jumper Selectable) Automatic or Manual 0. 00 to 14. 00 pH 0. 01 pH ± 0. 01 pH Relative accuracy Sensor Compensation Calibration (a) pH Number of calibration points Number of calibration buffers (b) Temperature Offset Adjustment Input /Output Input Output Display LCD Electrical Data and Connections pH/mV Input Connection terminal Other Power Input Dimensions (W x H x D) Weight (Estimated) Ambient Temp. operating range Maximum Relative Humidity 1 or 2 points USA: 1. 68, 4. 01, 7. 00, 10. 01, 12. 45 NIST: 1. 68, 4. 01, 6. 86, 9. 18 , 12. 45 ± 10 °C/ ± 18 °F Asymmetrical / Symmetrical None 7 segments display with symbols for status information Screw Terminal (3. 5mm pitch) 8-pin & 2-pin terminal blocks Universal +9 V DC Adaptor and 24V DC Supply 96mm x 96mm x 66 mm 210g 0 to 40 oC 80% up to 31 oC decreasing linearly to 50% at 40oC - 32 - 7 7. 1 LIST OF ACCESSORIES Thermo Scientific Order Codes pH Monitor Replacement and Accessories Item Description Alpha pH 550 Monitor Combination pH electrode with 5m cable Combination pH electrode with PMP and 5m cable Combination pH electrode with PT 100, PMP and 5m cable Combination pH electrode, submersible, with 5m cable Combination Gold ORP electrode with PMP and 5m cable Combination Platinum ORP electrode with PMP and 5m cable Calibration Solutions Item Description pH 4. 01 buffer solution, 480 ml bottle pH 7. 00 buffer solution, 480 ml bottle pH 10. 01 buffer solution, 480 ml bottle pH 4. 01 buffer sachets, 20 ml x 20 pcs. pH 10. 01 buffer sachets, 20 ml x 20 pcs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA PH1000 PHORP CONTROLLERTRANSMITTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag