Detailed instructions for use are in the User's Guide.
[. . . ] Alpha COND 1000
Controller/Transmitter uS/cm / mS/cm / ºC
ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTO-BAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTO-STIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. [. . . ] The upper display indicates the current temperature offset. The current measured temperature is shown in the lower A display. Compare the current measured temperature on the HOLD SETUP controller display to a thermometer known to be accurate. °C Note down the correct temperature. Press the or keys to scroll the lower display to match the correct value. The upper display will now show 25. 0 ATC the offset value. You can offset temperature up to ± 5 ºC. Press the ENTER key to confirm your selection. Continue with additional Advanced Set-up procedures, or return to the Measurement mode by pressing the and keys (escape) simultaneously).
2) 3) 4)
5)
6)
0. 0
7) 8)
7. 2. 1 Setting Manual Temperature Compensation HOLD SETUP NOTE: This parameter is blanked out when the controller is set for ATC operation. For manual temperature compensation, you can set two different temperatures: Process and Calibration. This allows A calibration at a temperature other than your process temperature. Example: setting a calibration temperature of 25 HOLD SETUP ºC lets you calibrate using standard buffer solutions at 25 ºC, °C even if your process temperature is at different temperature. c (use or keys to) scroll to Advanced Set-up security code "22". 2) Press the or keys to scroll until the display shows HOLD SETUP "SEt ºC". °C 3) Press the or keys to select "oFF ATC". c 4) The upper display shows the current process temperature and the lower display shows "P. ºC" to indicate process temperature. 5) Press the or keys to adjust the process temperature value. You can adjust the value from -9. 9 to 125 ºC.
FF
25. 0 25. 0
14
Operating Instructions
Thermo Scientific Alpha COND 1000
6)
After you set the process temperature value, press the ENTER key. The upper display shows the current calibration temperature and the lower display shows "C. ºC" to indicate calibration temperature. 7) Press the or keys to adjust the calibration temperature value. You can adjust the value from -9. 9 to 125 ºC. [. . . ] 600 Terminal blocks 5-pole / 17-pole, removable slow-blow 250 V / 100 mA According to EN 50081-1 According to EN 50082-1 0 to 50 C 10 to 95%, non-condensing 175 x 96 x 96 mm max. 0. 7 kg ABS with polycarbonate (front housing) IP 54 / IP 40
o
28
Operating Instructions
Thermo Scientific Alpha COND 1000
10 ACCESSORIES
Assembly Accessories Product Description Code no.
Conductivity Cell, up to 20S; Cell constant, K=0. 01 with EC-CS10-0-01S integrated Pt 100, Material SS316 and 25ft cable (open-ended) Conductivity Cell, up to 20S; Cell constant, K=0. 01 with EC-CS10-0-01T integrated Pt 100, Material Titanium and 25ft cable (openended) Conductivity Cell, 0. 1 - 200S; Cell constant, K=0. 1 with EC-CS10-0-1S integrated Pt 100, Material SS316 and 25ft cable (open-ended) Conductivity Cell, up to 200 mS; Cell constant, K=1. 0 with EC-CS10-1-0S integrated Pt 100, Material SS316 and 25ft cable (open-ended) Note: Above Conductivity Cells can withstand a pressure of up to 6 bar. Please ask your authorised distributor or dealer for the prices.
11 GENERAL INFORMATION
11. 1 Warranty Thermo Scientific warrants this product to be free from significant deviations in material and workmanship for a period of one year from the date of purchase. If repair is necessary and has not been the result of abuse or misuse within the warranty period, please return by freight pre-paid and amendment will be made without any charge. [. . . ]