Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CON 6. We hope that this EUTECH INSTRUMENTS CON 6 user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS CON 6.
Manual abstract: user guide EUTECH INSTRUMENTS CON 6
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
CON 6/TDS 6
Hand-held Conductivity/TDS Meter
68X243618
Technology Made Easy . . .
Rev. 3 06/06
Preface
This manual serves to explain the use of the Conductivity and TDS handheld meters. The models covered are the CON 6 and TDS 6. This manual functions in two ways: first as a step by step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the Conductivity and TDS handheld meters as possible. [. . . ] The five ranges are: Conductivity Range (CON 6) 0 20. 00 µS/cm 0 200. 0 µS/cm 0 2000 µS/cm 0 20. 00 mS/cm 0 200. 0 mS/cm TDS Range (TDS 6) (if TDS factor is 0. 5) 0 10. 00 ppm 0 100. 0 ppm 0 1000 ppm 0 10. 00 ppt 0 100 ppt
24
Instruction Manual
CON 6/TDS 6
Auto-ranging
Manual ranging: 0 - 20. 00 uS/cm
Manual ranging: 0 - 200. 0 uS/cm
µS
µS
µS
mS
mS
µS
Manual ranging: 0 - 200. 0 mS/cm
Manual ranging: 0 - 20. 00 mS/cm
Manual ranging: 0 - 2000 uS/cm
NOTE: If the value of the solution you are measuring is higher than the range selected [Or] will appear on the primary display. Press RANGE until the correct range is selected. The meter resets to the Auto-ranging function once it is turned off. You will have reset the manual ranging function each time you turn the meter off.
5. 5
25
Instruction Manual
CON 6/TDS 6
HOLD Function
This feature lets you freeze the display for a delayed observation. HOLD can be used any time in measurement mode. 1) To hold a measurement, press the HOLD key while in measurement mode. To release the held value, press the HOLD again. Continue to take measurements.
HOLD ENTER
µS
HO
2)
µS
NOTE: This meter shuts off automatically after 20 minutes of nonuse. If the meter is shut off either automatically or manually, the HOLD value will be lost.
26
Instruction Manual
CON 6/TDS 6
6 6. 1
ADVANCED SETUP FUNCTIONS Advanced Setup Overview
The advanced setup mode lets you customize your meter's preferences and defaults. To enter advanced setup mode: 1) 2) 3) 4) Make sure that the meter is switched-off. Press ON and MODE key simultaneously, holding both keys for 2 seconds. First release ON key first before releasing the MODE key. [StUP] indicator will appear momentarily and [CELC] will appear next. Overviews of CON 6 and TDS 6's Setup Menu as follows.
Enter Setup Page.
Select Cell Constant. "Yes" for auto calibration and "no" for manual calibration. (Available in CON 6 meter only)
%
Adjust Temperature Coefficient value from 0. 0 to 3. 0 %/°C. Default value is 2. 1 %/°C.
27
Instruction Manual
°C
CON 6/TDS 6
Select Normalization Temperature. Choice of either 20 °C or 25 °C. (Available in TDS 6 meter only) Select Single Point Calibration. Choice of "Yes" or "No". Choice of "Yes" or "No". Default value is "no".
Overview of Advanced Setup
28
Instruction Manual
CON 6/TDS 6
Meter Off
ON OFF
MODE
Press ON/OFF and MODE keys simultaneously for 2 seconds, release ON/OFF key first then release MODE key a second later. [. . . ] If you make measurements at extreme temperatures, calibrate the meter at least once a week.
You should only use the conductivity / TDS probe specified for these meters. These probes have a built-in temperature sensor. If you use a different probe without a temperature sensor, you must measure the solution temperature separately and manually enter the solution temperature (see manual temperature compensation section 5. 2)
47
Instruction Manual
CON 6/TDS 6
14
ADDENDUM 2: CALCULATING TDS CONVERSION FACTOR
You can calibrate your meter using TDS calibration standard solutions. The calibration standard only needs to give the TDS value at a standard temperature such as 25 °C. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CON 6
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CON 6 will begin.