If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER. We hope that this EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER.


Mode d'emploi EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER
Download
Manual abstract: user guide EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual pH 11 & pH 110 Hand-held pH / mV / Temperature / RS 232 Meter 68X361301 Technology Made Easy . . . Rev. 2 - 11/03 Preface This manual serves to explain the use of the hand-held series meters. The models covered are the pH 11 and the pH 110 hand-held meters. The manual functions in two ways, firstly as a step by step guide to help the user operate the meter. [. . . ] To switch on or off the Auto Hold feature, see section 9. 2. 1 P1. 1: READY Indicator and Auto Hold function on page 34. 20 Instruction Manual CyberScan pH 11 / 110 7 MEMORY FUNCTION The memory function is available in both pH 11 and pH 110 meters. These meters store data in sets: READY MEAS · · · pH and temperature mV and temperature Relative mV and temperature (for pH 110) MI 8. 23 2. 13 pH °C ATC The pH 11 meter can store up to 50 sets of data while pH 110 meter can store up to 100 sets of data. You can store data in any combination of values. For example, you can store 17 pH and 19 mV values. MEM MEM 7. 1 1. Memory Input During any measurement function (MEAS), press MI/ key to input any data into the memory. MEM, "Sto" and memory number will flash. The meter then returns to measurement mode. If the memory is full, the display will flash "MEM ­ FUL" momentarily (Figure 20). The first value stored will be erased to create space for the new value. MEM 1 2. 24 MI pH °C ATC FUL MEM MEM MEM 2 Figure 19: Data storage in memory MEM MEM 1 Figure 20: Memory full 21 Instruction Manual CyberScan pH 11 / 110 7. 2 Memory Recall MEAS This function recalls the previous readings stored in the memory. You can only access MR from the measurement mode. Memory recall is in "Last In First Out" order. Press the MR/ key once to retrieve the last reading stored. The memory location screen ­ MEM, "Loc" and the memory number ­ will flash on the display. Press the HOLD/ENTER key to recall the reading stored under that memory number. To display next stored reading, press HOLD/ENTER key. The display automatically moves to the next lower memory location screen. To view a stored reading in a specific memory location, press MI/ or MR/ keys to locate it, and press HOLD/ENTER key to display the reading. MR 7. 16 2. 3. loc 2 HOLD ENTER 4. MEM 5. 69 2. 24 HOLD ENTER pH °C ATC NOTE: Readings stored in memory are retained even if the unit is turned off. To erase all readings stored in memory, use the SETUP in section 9. 7 ­ P 6. 0: Memory Clear (CLr) on page 44. MEM MEM loc 1 HOLD ENTER loc 26 MR MI MEM 8. 23 2. 13 °C pH MEM loc 25 Figure 22: Scroll up or down for specific memory location ATC Figure 21: Memory recall 22 Instruction Manual CyberScan pH 11 / 110 8 PRINT FUNCTION (Only for pH 110) ) The pH 110 meter is equipped with an RS232 communication port and a PRINT ( key that facilitate the printing of data from the meter to a printer or computer. 8. 1 1. [. . . ] General purpose epoxy-body pH combination electrode, double-junction, 12x110 mm, 1-m cable length. "All-in-1" pH/Temperature (ATC) combination epoxy-body electrode, singlejunction, 12x110 mm, 1-m cable length. "All-in-1" pH/Temperature (ATC) combination epoxy-body electrode, doublejunction, 12x110 mm, 1-m cable length. Combination ORP electrode, epoxy-body, single-junction, 12x110 mm, 1-m cable length Combination ORP electrode, epoxy-body, double-junction, 12x110 mm, 1-m cable length RS232 Communication Cable: 9-pin male to 9-pin female connector, 1m cable length. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CYBERSCAN PH 110 PHMVRS232 METER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag