User manual EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER. We hope that this EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER.
Manual abstract: user guide EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER
Detailed instructions for use are in the User's Guide.
[. . . ] INSTRUCTION MANUAL
CYBERSCAN TURBIDIMETER TB1000
BENCH TURBIDITY METER
Technology Made Easy . . .
TABLE OF CONTENTS
1 2
2. 1 2. 2
INTRODUCTION UNPACKING THE INSTRUMENT
Packing List of Contents Unpacking and Inspection of the Instrument and Accessories
1 1
1 1
3 4
4. 1 4. 2
BECOMING FAMILIAR WITH THE INSTRUMENT ROUTINE OPERATION
Grab Sample Measurement (Routine Measurement) Pour Through Sample Measurement (Optional Accessory)
2 3
3 4
5
5. 1 5. 2
CALIBRATION PROCEDURES
Indexing the Calibration Standard(s) Calibration Procedure
4
4 5
6
6. 1 6. 2 6. 3 6. 4 6. 5 6. 6
USER SELECTABLE PARAMETERS
Setting the Year Setting the Day and Month Setting the Time Setting the Calibration Interval Setting the Printing Function Completing Selectable Parameters
6
6 6 6 6 7 7
7
7. 1
TROUBLESHOOTING
System Warning Message(s) 7. 1. 1 Flashing "Cal" block 7. 1. 2 Flashing "LoBat" block System Error Message(s) Factory Default Parameters
7
7 7 7 7 8
7. 2 7. 3
8
8. 1 8. 2 8. 3
ROUTINE MAINTENANCE
Cuvette Cleaning and Care Lamp Replacement Battery Replacement
8
8 8 9
9
SPECIFICATIONS
10 11
11
10 ACCESSORIES AND REPLACEMENT PARTS LIST
10. 1 Glossary
CyberScan TB1000
1
Introduction
Thank you for purchasing Eutech Instruments' CyberScan Turbidimeter TB1000 series White Light or Infrared turbidity meter (CyberScan TB1000 hereafter). These turbidity meters have been designed for simple and easy measurement of turbidity. This manual contains simple steps to follow to ensure that your instrument is operating properly. This material assumes that the user knows how to obtain representative samples of their process and has some familiarity with measuring the turbidity of samples. [. . . ] Select the correct day by pressing or keys to change the displayed day. When you have selected the proper day, press the ENTER key. NOTE: The CyberScan TB1000 is year 2000 (Y2K) compliant and automatically adjusts for leap years.
6. 3
Setting the Time
After pressing the ENTER key, the "Time" block will be displayed and you will see the time displayed on the lower row of the display in 24 hour format. The number flashing corresponds to the hour. Select the correct hour by pressing or key to change the displayed hour. When you have selected the proper hour, press the ENTER key. After pressing the ENTER key, the" Time" block will still be displayed and the second number on the lower row of the display will be flashing: this number corresponds to minutes. Select the correct minutes level by pressing or key to change the displayed minutes. When you have selected the proper minutes level, press ENTER key.
6. 4
Setting the Calibration Interval
After pressing the ENTER key, the upper row of the display will have the letters "Int" printed in it. This corresponds to the calibration time interval. The number in the lower row of the display corresponds to the number of days that you wish to have between scheduled calibrations (default is 30 days). Select the desired number of days between scheduled calibrations by pressing or key to change the displayed day. In normal automatic mode, if you exceed this number of days between calibration, the "Cal" block will flash until you re-calibrate the instrument. When you have selected the desired calibration interval press ENTER key.
6
CyberScan TB1000
6. 5
Setting the Printing Function
After pressing the ENTER key, the upper row of the display will have the letters "Prt" printed in it. This feature allows you to turn the printing option on the instrument on or off. Select the desired printing action (on or off) by pressing or key. When you have selected the proper printing option, press ENTER key. If you selected to turn off the printing function, pressing ENTER key will return you back to the normal mode of the instrument. If, on the other hand, you chose to turn on the printing function, pressing ENTER key will cause the "Baud" block to be highlighted and you can select the correct baud rate for operation of your printer. Select the desired baud rate (1200, 2400, 4800, or 9600) by pressing or key to change the displayed baud rate. The other RS 232 parameters are fixed at 2 stop bits, 8 data bits and odd parity. Once you have selected the proper baud rate, press ENTER key. [. . . ] If the instrument is unplugged during this procedure, all customer settings will be lost.
1. Remove the lamp module by first pressing the side tabs inward and pulling the module out. Then unplug the in-line lamp module connector by pulling the connector apart (see section 8. 2 for complete details on lamp replacement/removal). Place the instrument upside down on a soft surface. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CYBERSCAN TB 1000 TURBIDITY METER will begin.