User manual EUTECH INSTRUMENTS ECOSCAN SALT 6 METER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ECOSCAN SALT 6 METER. We hope that this EUTECH INSTRUMENTS ECOSCAN SALT 6 METER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ECOSCAN SALT 6 METER.


Mode d'emploi EUTECH INSTRUMENTS ECOSCAN SALT 6 METER
Download
Manual abstract: user guide EUTECH INSTRUMENTS ECOSCAN SALT 6 METER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Salt 6 Hand-held Salinity Meter 68X243619 Technology Made Easy . . . Rev 1 01/04 Preface This manual serves to explain the use of the Salt 6 salinity meter. It functions in two ways: first as a step by step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the Salt 6 salinity meter as possible. If there are doubts in the use of this meter, please do not hesitate to contact the nearest Eutech Instruments/ Oakton Instruments Authorized Distributor. [. . . ] 5) Wait for the value to stabilize and press or key and adjust the value to the calibration standard used. To use manual temperature compensation, you need to enter the temperature value of your process into the meter. This is the value at which the reading will manually temperature compensates. You can select any temperature between 0 and 50 °C. 1) Make sure that the phono jack (for temperature measurement) is disconnected from the meter. Switch on the meter and if necessary, press MODE key to select temperature measurement mode. start temperature °C CAL °C 2) 3) 4) 5) The "CA" will appear momentarily and a temperature value will starting flashing. Check the temperature of your sample using an accurate thermometer. Wait for the value to stabilize and press or key and adjust the value to the reference thermometer used. The [CO] indicator will appear for 1. 5 seconds, and the reading will stop flashing. The temperature calibration is successfully performed. The meter returns to measurement mode. HOLD ENTER °C 6) °C 16 Instruction Manual Salt 6 5. 3 1) Taking Measurements Rinse the probe with de-ionized or distilled water before use to remove any impurities adhering to the probe body. To avoid contamination or dilution of your sample, rinse probe with a small volume of your sample liquid. Allow time for the reading to stabilize. NOTE: When dipping the probe into the sample, take care to ensure that the liquid level is above its upper steel band. Stir the probe gently in the sample to create a homogenous sample. See Figure in Section 3. 4. To take readings: 2) 3) 4) 17 Instruction Manual Salt 6 5. 4 HOLD Function % This feature lets you freeze the display for a delayed observation. HOLD can be used any time in measurement mode. 1) To hold a measurement, press the HOLD key while in measurement mode. To release the held value, press the HOLD again. Continue to take measurements. HOLD ENTER HO % 2) NOTE: This meter shuts off automatically after 20 minutes of non usage. If the meter is shut off either automatically or manually, the HOLD value will be lost. 18 Instruction Manual Salt 6 6 6. 1 ADVANCED SETUP FUNCTIONS Advanced Setup Overview The advanced setup mode lets you customize your meter's preferences and defaults. [. . . ] 2 Temperature calibration error. Auto calibration is performed outside the temperature range (0 ­ 50 °C). * See Sections on "Warranty" and "Return of Items". 27 Instruction Manual Salt 6 If an error message appears, switching off the meter and switching it on again may eliminate the error message. If error persists, or the meter shows incorrect values, return the meter. For a complete diagram of the display see page 3. See sections on "Warranty" and "Return of items". LO µS 28 Instruction Manual Salt 6 10 SPECIFICATIONS SPECIFICATIONS Percentage (%) Range Resolution Accuracy TDS Range Resolution Accuracy Temperature Range Resolution/Accuracy Cell Constant Temperature Compensation Temperature Coefficient Normalization Temperature Saline Conversion Factor Number of calibration points HOLD Function Auto Power off Inputs Display Power Requirements Battery Life Dimension / Weight DESCRIPTIONS 0. 10 to 5. 00 % 0. 01 % ±1% F. S. -10. 0 to 110. 0 °C 0. 1 °C / ± 0. 5 for °C 1. 0 Automatic / Manual (from 0 to 50 °C) 0. 0 to 3. 0% / °C 20. 0 °C and 25. 0 °C (selectable) Non-linear Compensation 1 point Yes 20 minutes after last key operation BNC for conductivity and phono jack for temperature Single Custom LCD 4 `AAA' Batteries > 100 hours Meter: 14 x 7 x 3. 5 cm; 200 g 29 Instruction Manual Salt 6 11 ACCESSORIES Replacement Meter and Meter accessories Item Eutech Instruments Ordering Code Salt 6 portable salinity meter complete with conductivity probe of k=1. 0 (CONSEN91B). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ECOSCAN SALT 6 METER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ECOSCAN SALT 6 METER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag