User manual EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS. We hope that this EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS.


Mode d'emploi EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS
Download
Manual abstract: user guide EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual 24-hour Continuous Field Monitors pH, ORP, and Conductivity 68X254901 Technology Made Easy . . . Rev. 5 08/03 Preface This manual serves to explain the use for all models of the Field Monitors for pH, ORP, and Conductivity (each model sold separately). If there are doubts in the use of this meter, please do not hesitate to contact the Authorized Distributor. Eutech Instruments/ Oakton Instruments cannot accept any responsibility for damage or malfunction to the meter caused by improper use of the instrument. [. . . ] Be sure to remove the protective electrode storage bottle or rubber cap of the probe before calibration or measurement. If the electrode has been stored dry, wet the probe in tap water for 10 minutes before calibrating or taking readings to saturate the ORP electrode surface and minimize drift. Do not reuse calibration solutions after calibration. Dispose of any used calibration solution. Contaminants in the solution can affect the calibration, and eventually the accuracy of the measurements. IMPORTANT: ORP offset adjustment is limited to ±100 mV from the original reading. NOTE: All new calibration data will over-ride existing calibration data. 5 5. 2 ORP Calibration 1. The monitor will Immerse ORP electrode into a calibration standard solution, be in ORP measurement mode. for example, 255 mV 2. Rinse the probe thoroughly with de-ionized water or a rinse solution. Do not wipe the probe; this causes a build-up of electro-static charge on the surface. Dip the probe into the calibration standard. The end of the probe must be completely immersed into the sample. Let probe soak 2 to 5 minutes or until readings stabilizes. Press the CAL key to enter the calibration mode. "CA" will flash on the display for a second and then a value close to the calibration standard will flash. Press the or keys to adjust the display to match the calibration standard value. "CO" will flash on the display. The reading should now display the same value as the calibration standard. See Figure 3. Press Press Press Figure 5 - ORP Calibration Procedure 6 6 CONDUCTIVITY CALIBRATION This section is applicable for the following models: Description Conductivity FMCON 1 with Conductivity electrode and 110/120 VAC power adapter. "CA" will flash on the display for a second and then a value close to the calibration standard will flash. Press the or keys to adjust the display to match the calibration standard value. "CO" will flash on the display. [. . . ] ORP When ORP value is When ORP value is more than 995 mV. less than 0 mV Conductivity When Conductivity When Conductivity Displays when there value is more than value is less than 0 is an error in 10. 0 mS. calibration. 11 11 SPECIFICATIONS SPECIFICATIONS pH ORP FM CON1 Conductivity FM CON2 FM CON3 Range Accuracy Resolution Calibration 0. 0 to 14. 0 pH ± 0. 1 pH 0. 1 pH Up to 3 points; pH 4. 0, 7. 0 & 10. 0 Yes 0 to 995 mV ± 5 mV 5 mV Single- point, Offset ± 100 mV 0 to 10. 0 mS ±0. 2 mS/cm 0. 1 mS/cm 0. 0 to 990 µS ±20 µS/cm 10 µS/cm 0. 0 to 150 µS ±2 µS/cm 1 µS/cm Single- point, ± 30% full scale Automatic Buffer Recognition Automatic Temperature Compensation Operating Temperature Inputs Display Environmental Requirements Yes 0 to 50 °C (0 to 120 °F) BNC BNC 3-digit LED (Red) Operating: 0 to 50 °C (0 to 120 °F) Storage: - 10 to 60 °C (14 to 140°F) Humidity Limits: 10 to 95% RH (non condensing) AC / DC Adapter 9 V, 200 mA Meter: 19 x 10 x 6 cm; 80 g Boxed: 24 x 23 x 7 cm; 550 g Permanently wired Power Requirements Dimension / Weight 12 12 METERS AND ACCESSORIES Meters Item Eutech Instruments Ordering Code pH Field Monitor with pH electrode , 1 Strip of 10 pH 7 buffer tablets and 110/120 VAC power adapter. pH Field Monitor with pH electrode , 1 Strip of 10 pH 7 buffer tablets and 220/230 VAC power adapter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS FIELD PHORPCONDUCTIVITY MONITORS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag