Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS HIGHLOW TDS TESTER. We hope that this EUTECH INSTRUMENTS HIGHLOW TDS TESTER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS HIGHLOW TDS TESTER.
Manual abstract: user guide EUTECH INSTRUMENTS HIGHLOW TDS TESTER
Detailed instructions for use are in the User's Guide.
[. . . ] Soak electrode for a few minutes in alcohol to remove oils.
Conductivity Testing
1. Wait for reading to stabilize (Automatic Temperature Compensation cor rects for temperature changes). Note: Tester automatically shuts off after 8. 5 minutes of non-use.
Calibration
Tester is factory calibrated. However, to ensure accuracy, calibrate conductivity on a regular basis. [. . . ] The tester accepts calibration value; returns to measurement mode. Replace battery cap.
HOLD Function
Press HOLD key to freeze display. Press HOLD again to release.
Tester Maintenance
· To improve performance, clean the electrode by rinsing them in alcohol for 10 to 15 minutes. · Replace all batteries if low battery indicator appears, or if readings are faint or unstable. · If you experience drift, periodically let electrode fully dry. When you need a new electrode, see "Electrode Replacement" on insert in back of box.
Self-Diagnostic Messages
bAt Weak batteriesreplace with fresh ones specified by manufacturer. Or, Ur Over range/Under range signal, or electrode is not in contact with solution, or electrode is failing. ---- Calibration mode activated but not performed.
68X247754 11/00 Rev 0
Open this leaflet for calibration/testing/maintenance instructions.
Changing Batteries
1. Open battery INC compartment lid (with attached lanyard loop). Remove old batteries; replace with fresh ones. Note polarity DEC as shown Diagram 1 in battery compartment. Recalibrate after battery change.
Tester Maintenance
· To improve performance, clean the electrode by rinsing them in alcohol for 10 to 15 minutes. · Replace all batteries if low battery indicator appears, or if readings are faint or unstable. · If you experience drift, periodically let electrode fully dry. When you need a new electrode, see "Electrode Replacement" on insert in back of box.
Warranty
Eutech Instruments warrants its meter free from manufacturing defects for 2 years and electrode module for 6 months. If repair, adjustment or replacement is necessary and has not been the result of abuse or misuse within the time period, please return the tester freight prepaid and correction will be made without charge. Out of warranty products will be repaired on a charge basis.
+ +
Return Of Items
Authorization must be obtained from Eutech's distributor before returning items for any reason. When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. Prices are subject to change without notice.
· Waterproof & Floats · Replaceable Electrode · Auto-off · Adjustable TDS Factor · Automatic Temperature Compensation (ATC)
WP TDScan High Instructions
Before You Begin
Remove electrode cap. Soak electrode for a few minutes in alcohol to remove oils.
TDS Testing
1. Wait for reading to stabilize (Automatic Temperature Compensation corrects for temperature changes). [. . . ] Select a calibration standard appropriate for the TDScan Low tester (between 200 ppm and 1990 ppm). It is best to select a standard close to the test solution value. Twist the collar counter clockwise (see picture A). Save the ribbed tester collar and O-ring for later use. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS HIGHLOW TDS TESTER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS HIGHLOW TDS TESTER will begin.