If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS PH 5 PLUS PH TEMP. We hope that this EUTECH INSTRUMENTS PH 5 PLUS PH TEMP user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS PH 5 PLUS PH TEMP.
Manual abstract: user guide EUTECH INSTRUMENTS PH 5 PLUS PH TEMP
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
pH 5+ pH/Temp pH 6+ pH/mV/Temp Ion 6+ pH/Ion/mV/Temp
Technology Made Easy . . .
68X243633 Rev 1 12/08
Part of Thermo Fisher Scientific
Preface
This instruction manual serves to explain the use of the pH 5+, pH 6+ and Ion 6+ meters. It functions in two ways: first as a step by step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the pH 5+, pH6+ and Ion 6+ meters as possible. If there are doubts in the use of this meter, please do not hesitate to contact the nearest Eutech Instruments Authorized Distributor. [. . . ] The display shows "bUF" blinking.
2. Press ENTER key to begin buffer group selection mode. Use the MODE key to toggle between USA, NIST or Pb as shown below.
-8-
Instruction Manual
pH 5+, pH 6+, Ion 6+
Press ENTER key to confirm your selection. The meter will automatically revert to pH measurement mode. The meter will save the selected group indefinitely until changed.
3. 1. 3
Resetting User Calibrated Values
The calibrated pH/mV/Ion values can be reset to factory default using the procedure below. Temperature offset will not be reset using this procedure. To abort press CAL to revert to measurement mode. Press and hold CAL while switching the meter on using the ON/OFF key. Turn on the meter and select ion mode by pressing MODE key if necessary. For best results, always begin with your lowest standard value, followed by the next lowest standard. Dip the ISE into your standard solution. Press CAL key to begin calibration mode. The display shows "CA" (to indicate calibration mode) momentarily followed by "0. 1" flashing. To select the appropriate standard, use and keys.
-10-
Instruction Manual
pH 5+, pH 6+, Ion 6+
3. Press ENTER to confirm that the ppm value is the desired standard. The displayed value now shows the corresponding mV reading for the selected ppm value selected. When the mV reading is stable, press ENTER to complete the 1 point calibration. The display will show the next highest calibration standard value. Dip the electrode into your next highest standard solution. Press CAL key to begin calibration mode. Press ENTER to confirm that the ppm value is the desired standard. The displayed value now shows the corresponding mV reading for the selected ppm value selected. [. . . ] Ensure correct pH buffer group was selected. Check ISE is in good working condition-refer to ISE manual (Ion 6+). Ensure any calibration points between each other must be within 1 decade. (Ion 6+) a) Release reading by pressing HOLD. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS PH 5 PLUS PH TEMP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.