User manual EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER. We hope that this EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER.


Mode d'emploi EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER
Download
Manual abstract: user guide EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual C401/301/201/102/101 Portable Colorimeter 68X357704 Rev. 0 08/04 Technology Made Easy . . . Preface This manual functions in two ways: first as a step by step guide to help you operate the waterproof C401/301/201/102/101 Colorimeter; second, it serves as a handy reference guide. It contains basic instructions that you must follow during the operation, care and maintenance of the instrument. The safety protection provided by this equipment may be impaired if it is used in a manner not described in this manual. [. . . ] 2. 5. 2 Sample Measurement Due to the nature of the test method, concentrations less than 5 ppm Cyanuric Acid are not detectable. Clean the vial immediately after taking and recording a reading. Do not leave the sample with added reagent into the vial for more than few minutes after measurement. The test will cause the build up of a cloudy layer on the inside wall of the vial. It is important to thoroughly clean the vial after use to remove this layer because subsequent test results may be affected. 2. 5. 3 Interferences Sample Turbidity: Turbid samples should be filtered prior to analysis. 2. 5. 4 Accuracy Check / User Calibration A stock solution of 1000ppm Cyanuric Acid may be produced by dissolving exactly 1g of Cyanuric Acid in 1 litre of de-ionised water (check the purity of the Cyanuric acid being used; if less than 100%, adjust the amount used accordingly). The stock solution may then be diluted to give a Cyanuric Acid standard. To do this take a portion of the stock solution and make up to 1 litre using de-ionised water (for example, 50ml of stock solution will produce a 50ppm standard). To check the accuracy of the meter: Prepare a standard in the range 20-80 ppm (it is advisable to check a standard at near the concentration usually tested for using the meter). Use this standard in place of the sample water in the above test method. The result obtained should be approximately the value of the standard used (please refer to instrument's specifications for data on meter precision and accuracy). To re-calibrate the meter: All instruments are factory calibrated and user calibration is not recommended. However, if a Cyanuric Acid standard can 17 Measurement: Cyanuric Acid C401/301/201/102/101 be accurately prepared, or measured by a different method or instrument of higher precision and accuracy, then a Cyanuric Acid standard in the 6675 ppm range can be used. Please refer to section 3. 3 Cyanuric Acid for details. 2. 5. 5 Chemistry Cyanuric Acid is commonly used to stabilize the chlorine present in swimming pool water. With correct pool maintenance, Cyanuric Acid build-up is uncommon; however, if correct maintenance is not carried out, the levels may build up until potentially harmful. In the test method, the Cyanuric acid reacts with the sachet reagent, in a conditioned sample, to produce a suspended turbidity. The amount of turbidity produced is proportional to the concentration of Cyanuric Acid. The amount of 525nm light absorbed/scattered by the turbidity is accurately measured by the meter and then converted into the Cyanuric Acid concentration. 18 Measurement: pH C401/301/201/102/101 2. 6 · pH (5. 9-8. 2 pH units) For water and wastewater (Phenol Red Method) Switch the meter on by pressing the ON/OFF key. Press the MODE key repeatedly until [PH] is displayed. Press the READ/ENTER key to confirm the test parameter. [. . . ] The batteries need to be replaced. Return the unit for repair. Replace the batteries. * If an error message appears, take the appropriate corrective action and re-do the desired procedure. If the problem persists, contact Eutech Instruments or your dealer. See Sections on Warranty and Return of Items on page 39. 35 Routine Maintenance C401/301/201/102/101 5 ROUTINE MAINTENANCE The supplied carrying case is optimal for protecting the instrument. If you do not plan on leaving the instrument in the supplied carrying case, when not in use, ensure that the instrument has been turned off and that a clean sample vial fitted with a black cap has been placed in the sample well. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS WATERPROOF C401 COLORIMETER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag