User manual EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER. We hope that this EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER.
Manual abstract: user guide EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
PC 300
Waterproof Hand-held pH/Conductivity/TDS/Temperature Meter
35631-00
Technology Made Easy . . .
68X248908 Rev3 01/04
Preface
This manual serves to explain the use of the Waterproof PC 300 hand-held meter. It functions in two ways, firstly as a step by step guide to help you to operate the meter. Secondly, it serves as a handy reference guide. It is written to cover as many anticipated applications of the Waterproof PC 300 hand-held meter as possible. [. . . ] The sub-groups are: For pH P 1. 0 P 2. 0 P 3. 0 P 4. 0 View calibration data (CAL) View electrode data (ELE) Unit Configuration (COF) Reset to factory default P 5. 0 P 6. 0 P 7. 0 P 8. 0 For Conductivity & TDS View calibration data (CAL) View electrode data (ELE) Unit Configuration (COF) Temperature (tPr)
settings (rSt) P 9. 0 Reset to factory default
settings (rSt)
See Figure 25 on next page.
29
Instruction Manual
PC 300
Figure 25 - Overall view of SETUP programs for pH (on left) and conductivity/TDS (on right)
30
Instruction Manual
PC 300
7. 1
1.
Advanced SETUP Mode Overview
In either pH or Conductivity measurement mode, press the SETUP key to enter Set up mode.
2. 3.
Press the
or
keys to scroll through sub groups.
Press ENTER key to enter a particular parameter.
See Addendum 4 for a table of meter factory default settings.
SETUP in pH Measurement Mode
P1. 0: View previous calibration data P1. 1 P1. 2 P1. 3 P1. 4 P1. 5 First calibration point (pH 1. 68) Second calibration point (pH 4. 01) Third calibration point (pH 7. 00 or 6. 86) Fourth calibration point (pH 10. 01 or 9. 18) Fifth calibration point (pH 12. 45)
Instructions on Section 7. 2. P2. 0: View electrode data P2. 1 P2. 2 pH electrode offset pH electrode slope
Instructions in Section 7. 3. P3. 0: Unit configuration P3. 1 P3. 2 P3. 3 P3. 4 READY indicator and auto endpoint function select on or off Number of pH calibration points: 2, 3, 4 or 5 Select buffer group: USA or NIST Select °C or °F
Instructions in Section 7. 4. P4. 0: Reset to factory defaults P4. 0 Reset meter to factory defaults
Instructions in Section 7. 5.
31
Instruction Manual
PC 300
SETUP in Conductivity Measurement Mode
P5. 0: View previous calibration data P5. 1 P5. 2 P5. 3 P5. 4 P5. 5 First range calibration point (0. 00 19. 99 µS) Second range calibration point (0. 0 199. 9 µS) Third range calibration point (0 1999 µS) Fourth range calibration point (0. 00 19. 99 mS) Fifth range calibration point (0. 0 199. 9 mS)
Instructions in Section 7. 6. P6. 0: View electrode data P6. 1 Effective cell constant for first range (0. 00 19. 99 µS) P6. 2 Effective cell constant for second range (0. 0 199. 9 µS) P6. 3 Effective cell constant for third range (0 1999 µS) P6. 4 Effective cell constant for fourth range (0. 00 19. 99 mS) P6. 5 Effective cell constant for fifth range (0. 0 199. 9 mS) Instructions in Section 7. 7. P7. 0: Unit configuration READY indicator and auto endpoint function select on or off P7. 2 Select °C or °F P7. 3 Select Automatic or Manual Temperature Compensation P7. 4 Setting TDS conversion factor Instructions in Section 7. 8. P8. 0: Temperature P8. 1 P8. 2 Adjusting temperature coefficient Adjusting normalization temperature P7. 1
Instructions in Section 7. 9. P9. 0: Reset to factory defaults P9. 0 Reset meter to factory defaults
Instructions in Section 7. 9. 1.
32
Instruction Manual
PC 300
SETUP in TDS Measurement Mode
P5. 0: View previous calibration data P5. 1 P5. 2 P5. 3 P5. 4 P5. 5 First range calibration point (0. 00 9. 99 ppm) Second range calibration point (0. 0 99. 9 ppm) Third range calibration point (0 999 ppm) Fourth range calibration point (0. 00 9. 99 ppt) Fifth range calibration point (0. 0 200 ppt)
Instructions in Section 7. 6. P6. 0: View electrode data P6. 1 Effective cell constant for first range (0. 00 9. 99 ppm) P6. 2 Effective cell constant for second range (0. 0 99. 9 ppm) P6. 3 Effective cell constant for third range (0 999 ppm) P6. 4 Effective cell constant for fourth range (0. 00 9. 99 ppt) P6. 5 Effective cell constant for fifth range (0. 0 200 ppt) Instructions in Section 7. 7. P7. 0: Unit configuration P7. 1 READY indicator and auto endpoint function select on or off P7. 2 Select °C or °F P7. 3 Select Automatic or Manual Temperature Compensation P7. 4 Setting TDS conversion factor Instructions in Section 7. 8. P8. 0: Temperature P8. 1 P8. 2 Adjusting temperature coefficient Adjusting normalization temperature
Instructions in Section 7. 9. P9. 0: Reset to factory defaults P9. 0 Reset meter to factory defaults
Instructions in Section 7. 9. 1.
33
Instruction Manual
PC 300
7. 2
P1. 0: Viewing previous pH calibration data
This mode lets you recall previous pH calibration data, which helps you know when to recalibrate your meter. Press the MODE key to select pH measurement mode if necessary. Press the SETUP key to enter Set up mode. Press the or keys to scroll through subgroups
until you view parameter P1. 0. Press the ENTER key repeatedly to view previous calibration data. USA · · · · · 5. P1. 1 = pH 1. 68 P1. 2 = pH 4. 01 P1. 3 = pH 7. 00 P1. 4 = pH 10. 01 P1. 5 = pH 12. 45 NIST 1. 68 4. 01 6. 86 9. 18 12. 45
When you have scrolled through all calibration data, you will automatically return to the subgroup menu. Press CAL/MEAS key to return to measurement mode.
Figure 26 P1. 0: View calibration data for pH
NOTES: If there is no previous calibration data at a particular point, the primary display will show "- - -".
34
Instruction Manual
PC 300
7. 3
P2. 0: Viewing pH electrode data
Program 2 has two "view only" options that let you check the electrode parameters for diagnostic purposes. It lets you view: · · P2. 1 = Electrode offset P2. 2 = Electrode slope
From pH measurement mode 1. Press the MODE key to select pH measurement mode. [. . . ] The lower display reads tCO and the upper display shows the temperature coefficient value (should be 0, as per step 1 above). key until the upper display shows your calculated temperature
Press ENTER key to confirm the value. Press CAL/MEAS key twice to return to measurement mode.
The calculated temperature coefficient will not be applied to all the meter readings.
61
Instruction Manual
PC 300
16 ADDENDUM 4: METER FACTORY DEFAULT SETTINGS
Resetting the meter to factory default settings clears all calibration data and most other setup functions you might have changed. The following settings will remain as you have set them: · · Temperature unit of measure (°C or °F) The temperature offset calibration value.
NOTE: Conductivity and pH data are cleared separately from each other. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PC 300 PHCONDUCTIVITYTDS METER will begin.