If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PH 300310 PHMV METER. We hope that this EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PH 300310 PHMV METER user guide will be useful to you.
Lastmanuals help download the user guide EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PH 300310 PHMV METER.
Manual abstract: user guide EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PH 300310 PHMV METER
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
pH 300/310
Waterproof Hand-held pH / mV / Temperature Meter
68X248901
Technology Made Easy . . .
rev 6 08/04
Preface
This manual serves to explain the use of the waterproof pH 300/310 hand-held meter. It functions in two ways, firstly as a step by step guide to help you to operate the meter. Secondly, it serves as a handy reference guide. It is written to cover as many anticipated applications of the waterproof pH 300/310 meter as possible. [. . . ] MEM, "Sto" and memory number will flash. The meter then returns to measurement mode. NOTE: If the memory is full, the first value stored will be erased to create space for the new value.
Figure 17 - Memory Input
18
6. 2
Memory Recall
This function recalls the previous readings stored in the memory. You can only access MR from the measurement mode. Memory recall is in "Last In First Out" order. Press the MR key once to retrieve the last reading stored. The memory location screen MEM, "Loc" and the memory number will flash on the display. Press the ENTER key to recall the reading stored under that memory number.
For pH 300 meter only: Press the ENTER key again to return to the "memory location" screen. See Figure 18.
For pH 310 meter only: Press the ENTER key again to view the date (Month/Day format) and time (Hour/Minute format) the reading was taken. Press ENTER key again to return to the "memory location" screen.
3.
The display automatically moves to the next lower memory location screen.
Figure 18 - Memory recall function
See figure 20.
19
4.
If necessary, press the MI/ key to select the next "memory location" screen; press the MR/ key to select the previous "memory location" screen.
5.
Repeat steps 2 to 5 to review additional stored data sets.
6.
To exit Memory Recall, press the MEAS key to return to the Measurement mode.
Figure 19 - View date and time (available only for pH 310 meter)
NOTES: Readings stored in memory are retained even if the units are turned off. To erase all readings stored in memory, use the SETUP mode P1. 0 on page 25.
Figure 20 - Next Memory Recall value
20
7
ADVANCED SETUP FUNCTIONS
The advanced setup mode lets you customized your meter's preferences and defaults. This meter features different sub groups that organize all setup parameters. P1. 0: P2. 0: P3. 0: P4. 0: P5. 0 (pH 300 only): P5. 0 (pH 310 only): 6. P6. 0 (pH 310 only): Memory clear (CLr) Viewing calibration data (CAL) Viewing electrode data (ELE) Unit configuration (COF) Reset to factory default settings (rSt) Setting clock (CLO) Reset to factory default settings (rSt)
See Figure 21 and 22.
21
Figure 21 - pH 300 Advanced Setup Subgroups
Figure 22 - pH 310 Advanced Setup Subgroups
22
7. 1
Advanced SET-UP Mode Overview
Press the SETUP key to enter Set up mode. Press the MI/ or MR/ keys to scroll through sub groups.
pH 300 meter set up mode
P1. 0: Memory clear P1. 0 Clear all stored readings
P2. 0: Viewing previous calibration data P2. 1 P2. 2 P2. 3 P2. 4 P2. 5 View first calibration point (pH 1. 68) View second calibration point (pH 4. 01) View third calibration point (pH 7. 00) View fourth calibration point (pH 10. 01) View fifth calibration point (pH 12. 45)
P3. 0: Viewing electrode data In pH measurement mode: P3. 1 P3. 2 P3. 1 P4. 1 P4. 2 pH electrode offset pH electrode slope Relative mV offset READY indicator on or off Number of calibration points: 2, 3, 4 or 5
In mV (or relative mV) measurement mode: P4. 0: Unit configuration
P5. 0: Reset to factory default P5. 0 Reset to factory default settings
23
pH 310 meter setup mode
P1. 0: Memory clear P1. 0 Clear all stored readings
P2. 0: Viewing previous calibration data (USA, NIST or DIN standards) P2. 1 P2. 2 P2. 3 P2. 4 P2. 5 First calibration point (plus time and date) Second calibration point (plus time and date) Third calibration point (plus time and date) Fourth calibration point (plus time and date) Fifth calibration point (plus time and date)
P2. 6 Sixth calibration point (plus time and date) (only for DIN buffer set) P3. 0: Viewing electrode data In pH measurement mode: P3. 1 P3. 2 P3. 1 P4. 1 P4. 2 P4. 3 P4. 4 · · · pH electrode offset pH electrode slope Relative mV offset READY indicator on or off Number of calibration points: 2, 3, 4 or 5 (or 6 for DIN buffer set only) Calibration buffer selection sets Selecting °C or °F Setting year Setting date (month/day) Setting time (hour/minute/second)
In mV (or relative mV) measurement mode: P4. 0: Unit configuration
P5. 0: Setting Clock
P6. 0: Reset to factory default P6. 0 Reset to factory default settings
24
7. 2
P 1. 0: Memory Clear (CLr)
Use this parameter to clear all memory values when you need to store a new series of values. This lets you avoid confusing the old values with the new ones. NOTE: Selecting YES will wipe out all memory. Press the SETUP key to enter Set Up mode. Press the MI/ or MR/ keys to scroll through subgroups until you view the parameter P1. 0. Press the ENTER key to enter parameter P1. 0. Press the MI/ or MR/ keys to toggle between NO and YES. NO retains current memory YES clears all memory. [. . . ] Waterproof pH 310 Hand-held pH meter in carrying case kit. Complete with temperature probe, pH electrode (1m cable) and pH carrying kit set. Hard plastic carrying case kit for pH 300/310 meter. EC-PHWP300/02K Oakton Instruments Order Code 35617-70
EC-PHWP310/02K
35618-72
EC-PHWP-KIT (with 3 pH buffer solution (pH 4. 01, 7. 00, & 10. 01) in 60-ml bottle, and 1 empty rinse/waste water bottle (480-ml) EC-PHWP300/01
35614-79 (Includes five of each pH buffer pouch)
Waterproof pH 300 Hand-held pH meter complete with temperature probe only.
35618-02 "Temperature probe sold separately"
Waterproof pH 310 Hand-held pH meter complete with temperature probe only. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS WATERPROOF CYBERSCAN PH 300310 PHMV METER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.