[. . . ] The following pages will familiarize you with the procedures for operating the LEGEND Security System. Thank You, FIRE BURGLARY INSTRUMENTS
LEGEND Users Manual
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Keypad Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In addition to this constant visual indication, the zone indicator lights will provide additional information concerning the current zone status. This light will also blink if there is a visual alarm condition present. 11- STAY Key The STAY key is used to activate (arm) the system with the exception of interior protection. This will provide exterior protection of your location while allowing full access through the location. This mode would be used when arming the system and you might be walking through protected interior zones. 12--BYPASS Key The BYPASS key will be used to temporarily turn off protection of a portion of your burglary protection. This could be performed, for example, to ignore an open window which would prevent the arming of your system. 13- INSTANT Key The INSTANT key is used to activate (arm) the system and eliminates the entry delay. This would cause an immediate alarm if someone came through an exit/entry zone. 14- CODE Key Function key used when entering or changing the User access codes of your system. INSTANT STAY CODE [USER] *
# +
6
5
ARMING THE SYSTEM
ARMING the system will activate all portions of your Security System. Note: The STAY option will automatically be reset after the system is disarmed. 8
BYPASS INSTANT
The INSTANT mode arms the system and eliminates the entry time delay interval. If anyone enters through an entry/exit zone the alarm system will instantly activate. The system must be ready to select the INSTANT option. INSTANT PROCEDURE INSTANT [USER] Depress the INSTANT key followed by your user code. Upon sucessful INSTANT ARMING of the system the ARMED and INSTANT indicators will be lit. Note: The INSTANT option will automatically be reset after the system is disarmed. Bypasses are performed to eliminate burglary zones that are not ready or faulty from activating the security System. BYPASS PROCEDURE: BYPASS [USER] ZN Depress the BYPASS key followed by your user code and the two digit zone number to be bypassed. The zone number to be bypassed is shown as ZN. For example, to bypass zone number 2 enter; BYPASS [USER] 02 Multiple zones may be bypassed by repeating the sequence for the desired number of zones within a fifteen second interval, as follows; EXAMPLE: BYPASS [USER] 02 BYPASS 04 BYPASS 12 The sequence displayed above would have bypassed zones 2, 4 and 12. [. . . ] IF NO ALARMS HAVE TAKEN PLACE Upon disarming the ARMING indicator will go off. The system display will reflect the current status.
FORCED ARMING
Forced Arming is a method that will automatically bypass all zones that are not ready and ARM the system. FORCED ARMING PROCEDURE; BYPASS [USER] BYPASS Depress the BYPASS key followed by your user code and the BYPASS key. If any of the zones currently faulted are not bypassable, then the command will not succeed, and a long interrupted beep will follow. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FBII LEGEND-100
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.