[. . . ] MDS
MDS MDS TECHNICAL MANUAL TECHNICAL MANUAL MANUAL
SECTION III - EQUIPMENT COMMON TO MDS DIGITAL, DIRECT and CITY SYSTEMS
Page 1
MDS
MDS TECHNICAL MANUAL The MDS technical manual is comprised of the following sections: - MDS Systems Introduction - Section I: MDS Digital System - Section II: MDS Direct and MDS City System - Section III: Equipment common to MDS Digital, Direct and City Systems - Section IV: Installation Diagrams
(Code. 94726Ib-4)
MDS Technical Manual - Section III Code 94726Ib-3 V04_08 This technical document of an informative nature is published by FERMAX ELECTRONICA S. A. E. , who reserve the right to modify characteristics of the products referred to herein at any time and without prior notice. These changes will be reflected in subsequent editions of this document.
Page 2
MDS
TABLE OF CONTENTS
SECTION III - EQUIPMENT COMMON TO MDS DIGITAL, DIRECT and CITY SYSTEMS
RESIDENTIAL TERMINALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Dimensions (Height x Width x Depth): 195x211x60 (mm)
Page 11
MDS
Operation of the Sailing Monitor
Call * When the call button is pressed on the Outddor Panel a call tone is emitted both on the outdoor panel and the monitor, switching on the monitor and switching off the ON-OFF indicators. If there is additional equipment in the residence, this will also sound. If the call is not answered the image on the monitor will disappear after 90 seconds.
ION LUT SO H RE NITOR HIG T MO FLA
1
2
Answering a call * On picking up the telephone receiver you can communicate with the visitor.
ION LUT SO H RE NITOR HIG T MO FLA
1 2
The duration of the communication is limited to the conversation time programmed for the MDS Direct and City Panels or the MDS Central Unit.
Open the door for the visitor * While communicating with the visitor you can open the door by pressing the button
ION LUT SO H RE NITOR HIG T MO FLA
1 2
.
Call Guard Unit * With the monitor on standby, when you press this button unit (where one exists). a call will be made to the guard
Page 12
MDS
4+N OLYMPO Monitors
The monitors used in the MDS video door entry systems are conventional monitors which do not require programming and are connected to the corresponding audio decoder output. The decoder is the part which establishes communication between the Panel or Guard Unit and the residential monitor called. The Olympo monitor is a half-duplex hands free monitor in full colour with a 5" TFT screen and polyphonic tones. Press the " " button again to select the current tone. Doorbell Tone: The monitor has a characteristic tone for the doorbell (if there is a button connected to the monitor connector's "E" and "+S" terminals.
Brightness ( ), contrast ( ) and colour ( ) adjustments: * With the screen on press the corresponding button to make the relevant adjustments. There are eight adjustment levels available in sequence.
P
F
Page 14
MDS
4+N Citymax Telephones
The 4+N telephones can be combined with other Fermax monitor and telephone models in the same MDS system. Also in systems with monitors as an additional piece of equipment in the home. In the same way as the 4+N monitors used in MDS systems, the telephones, following the installation and connection, do not need to be programmed to operate correctly. There are different versions of the Citymax monitor for MDS (in the same way as for 4+N) based on the number of auxiliary buttons on the monitor: Basic (no additional button), Extra (2 additional buttons) and Complet (5 additional buttons). If you require a Panic Button you will need to use an Extra or Complet telephones.
Control Descriptions
Door-opener / Call Guard. · When you are communicating with the Outdoor Panel, pressing this button will activate the door-opener. · When you press this button with the telephone on the hook, a call will be made to the guard unit (where one exists). Buttons for additional functions on EXTRA models (2 additional buttons) and COMPLET (5 additional buttons).
Installing the telephone
1 2
RE F. *** *
3
4
616E
61 6E
61 6E
Page 15
MDS
Page 16
MDS
EQUIPMENT COMMON to the MDS Digital, Direct and City Systems
Page 17
MDS
Power Supplies
The correct operation of any electric/electronic system depends largely on the use of the appropriate power supply. For this reason special care should be taken in choosing the model and number of power supplies necessary for our system. The MDS systems use two types of power supplies: 12 Vdc for audio and data and 18 Vdc for video. In this way, depending on the system (door system, video door system, access control, number of panels and/or readers installed, type of door-opener used, length of the line. . . . ) the power necessary may vary based on the model and number of power supplies: - Door Entry System Installation: 12Vdc. - Video Door Entry System Installation : 12Vdc and 18 Vdc. - Access control systems with and without door entry system: 12 Vdc. - Access Control Installation with Video Door Entry System: 12 Vdc and 18 Vdc. [. . . ] 5918
COLOUR WIRE SECTION Brown + 1 mm 2 Orange 1 mm 2 2 Sa White 0. 5 mm Black Sb 0. 5 mm 2 Red 2 1 mm 2 Blue 6 1 mm 2
USED 12 Vdc Audio common Data Transmision Data Transmision Audio apartment - outdoor panel Audio outdoor panel - apartment
Ref. 5919
COLOUR WIRE SECTION 1 mm 2 White CT Core Shield Red 1 mm 2 + Black 1 mm 2 -
USED Camera activation Video signal Shielded Video Supply 18Vdc
MDS System Sections Table DISTANCE (in metres) up to 300 300 to 500 500 to 1000 Audio Cables SECTION
Number of cables x Section Shielded Twisted Pair Section
Video Cables COAXIAL RG-59
4 x 1 mm
2
+ + + +
0. 5 mm2 shielded twisted pair 0. 5 mm2 shielded twisted pair 0. 5 mm2 shielded twisted pair 0. 5 mm2 shielded twisted pair 75 Ohm
4 x 1. 5 mm2 4 x 2. 5 mm2 4 x 4 mm2
1000 to 1500
Note
A MDS Repeater must be used Ref. 2339 for distances greater than 1200 metres. 4110 for distances greater than 250 metres. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FERMAX MDS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.