If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46115300. We hope that this FIELD CONTROLS 46115300 user guide will be useful to you.
Lastmanuals help download the user guide FIELD CONTROLS 46115300.
Manual abstract: user guide FIELD CONTROLS 46115300
Detailed instructions for use are in the User's Guide.
[. . . ] PVE SERIES POWER VENTER SYSTEM MANUAL
Contents I. Typical Venting System Components System Operation Power Venter Sizing Installation Safety Instructions Installation of Power Venter Connecting Power Venter to Appliance General Wiring Instructions Airflow Adjustments General Installation Inspection Maintenance Replacement Parts List System Operational Information
Page 2 3 3, 4 5, 6 6, 7 7 7 8 8, 9 9, 10 10 11
DO NOT DESTROY
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT
I.
TYPICAL VENTING SYSTEM COMPONENTS: 1 - PVE Series Power Venter 1 - SWH-1 Series Sidewall Vent Hood (Not included) 1 - CK Series Control Kit (Not included) A. DESCRIPTION OF POWER VENTER MODELS
Unit Dimensions (inches) MODEL "H" PVE-100 PVE-300 PVE-600 PVE-1200 7. 50 7. 50 8. 75 13. 75 "W" 7. 75 9. 25 9. 75 12. 50 "D" 7. 00 7. 00 8. 50 13. 50 INLET/ OUTLET 4. 00 4. 00 5. 00 8. 00 VOLTS 120 120 120 120 Hz 60 60 60 60
ELECTRICAL DATA RPM 3000 3000 3000 1725 WATTS 145 145 167 280 AMPS 2. 1 2. 1 1. 5 2. 5 THERMAL PROT. SIDEWALL VENT HOODS (SWH-1): Sidewall vent hoods are available in the following sizes. [. . . ] For oil appliances use a Field Controls Type M or RC Barometric Draft Control. Gas-fired draft induced systems should have a single-acting or double-acting barometric draft control installed.
V.
INSTALLATION OF POWER VENTER CAUTION: Failure to install, maintain and/or operate the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage. Remove power venter from box and inspect unit for damage. If the carton has been crushed or mutilated, check unit very carefully for damage. Rotate venter wheel to insure that the motor and venter wheel rotate freely. DO NOT install if any damage is apparent. Refer to unit sizing chart to check proper venting sizing. Location of the termination of the venting system should be installed in accordance with the National Fuel Gas Code, A. N. S. I. Z233. 1, manufacturer's recommendations, and/or local codes which are applicable. See the following requirements or refer to installation location Diagram A for typical locations. The exit termination of mechanical draft systems shall not be less than 7' above grade when located adjacent to public walkways. A venting system shall terminate at least 3' above any forced air inlet located within 10'. The venting system of other than a direct vent appliance shall terminate at least 4' below. 4' horizontally from or 1' above any door, window or gravity air inlet into the building. The vent termination of a direct vent appliance with an input of 50, 000 BTU/Hr or less, shall be located at least 9" from any opening through which vented gases could enter the building. With an input over 50, 000 BTU/Hr, a 12" termination clearance shall be required. The vent termination point shall not be installed closer than 3' from an inside corner of an L-shaped structure. The vent termination should not be mounted directly above or within 3' horizontally from an oil tank vent or gas meter. The bottom of the vent terminal shall be located at least 12" above finished grade.
B.
4.
5. The power venter should never be installed with the venter motor in the vertical position. This could lead to premature motor failure. The venter outlet can be oriented at any angle, from horizontal to vertical. The power venter should be installed as close to the outside wall as possible.
Page 6
Diagram A
PVE Side Wall Vent Termination Locations
VI. [. . . ] This can indicate reduced available combustion air to burner. If appliances are equipped with high and low flame control or flame modulation, check for proper main burner operation at low flame. Test for spillage at draft hood or barometric draft control opening and burner inlet air location after 5 minutes of main burner operation. Use a draft gauge, flame of a match or candle, smoke from a cigarette, cigar or pipe. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46115300
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.