User manual FIELD CONTROLS 46144900 CK-61

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46144900 CK-61. We hope that this FIELD CONTROLS 46144900 CK-61 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46144900 CK-61.


Mode d'emploi FIELD CONTROLS 46144900 CK-61
Download
Manual abstract: user guide FIELD CONTROLS 46144900 CK-61

Detailed instructions for use are in the User's Guide.

[. . . ] Install the flexible conduit connector onto the CK-61 Junction Box and secure with fastening nut. If remote mounting the CK-61 Junction Box, mount the flexible conduit connector onto a 2" x 4" installer supplied junction box. Fasten the flexible conduit from the SWG Venter into the conduit connector. Mount the CK-61 Junction box or installer supplied junction box onto the wall or floor joist without straining the flexible conduit. [. . . ] When routing the tubing avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-61 Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. Refer to the SWG Venter installation instructions for setting system airflow. Figure 5 Figure 3 Figure 2 Figure 1 Figure 4 Page 2 WIRING INSTRUCTIONS Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. Caution must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for Class I wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. (Diagrams A through E) Diagram A ­ Oil Fired System: Single Unit Wiring Diagram B ­ Oil Fired System: Wiring with Electronic Primary Page 3 Diagram C ­ Typical Wiring for Oil Fired Warm Air Furnace with a Honeywell ST9103 Control Board Diagram D ­ Riello Burner Application Page 4 Diagram E ­ Multiple Oil Fired Systems Page 5 ADJUSTMENTS PRESSURE SWITCH ADJUSTMENTS With the venter air flow set and the appliance operating at the best operating efficiency, adjust the pressure switch by rotating the adjustment screw clockwise until the burner shuts off, then rotate the adjustment screw counterclockwise until the burner fires. Rotate the adjustment screw an additional 1/4 turn counterclockwise to ensure proper switch setting. (See Figure 6) POST PURGE TIMING ADJUSTMENT To adjust the post purge time, rotate the timer adjustment on the timer clockwise to increase the operation time. To decrease the operation time, rotate the timer adjustment counterclockwise. (See Figure 7) Typical post purge time should be between 3 to 5 min. Adjust the thermostat to call for heat and observe the power venting system for proper sequence of operation: (Repeat if necessary). Relay is energized, post purge timer is energized, and venter motor starts. Pressure switch closes and burner starts. Thermostat is satisfied, relay is de-energized, burner stops and post purge timer operates venter motor for approximately 3 to 5 minutes. While system is operating, disconnect power to the venter motor. This should open the pressure switch contacts and stop burner operation. [. . . ] Check wiring connections between pressure switch and burner. Check pressure switch for continuity across terminals, during venter operation. Venter does not activate when thermostat calls for heat. Jump wire the terminals L1 and M to ensure motor operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46144900 CK-61

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46144900 CK-61 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag