If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46334200. We hope that this FIELD CONTROLS 46334200 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46334200.


Mode d'emploi FIELD CONTROLS 46334200
Download
Manual abstract: user guide FIELD CONTROLS 46334200

Detailed instructions for use are in the User's Guide.

[. . . ] Diameter of Installer Maximum Maximum Flue Collar Provided Flue Equivalent Length Equivalent Length on Furnace Pipe Transition (ft. ) for 4" Vent Pipe (ft. ) for 5" Vent Pipe Size Diameters 46, 000 4" None 100 100 69, 000 4" None 100 100 92, 000 4" None 100 100 115, 000 4" None 85 95 138, 000 4" None 65 80 For Furnace Models GCIA, GCIB, and GCIC BTU/Hr. Diameter of Installer Maximum Maximum Flue Collar Provided Flue Equivalent Length Equivalent Length on Furnace Pipe Transition (ft. ) for 4" Vent Pipe (ft. ) for 5" Vent Pipe Size Diameters 46, 000 3" 3" to 4" 100 100 69, 000 3" 3" to 4" 100 100 92, 000 3" 3" to 4" 100 100 115, 000 3" 3" to 4" 85 95 138, 000 3" 3" to 4" 65 80 Page 2 For Furnace Models GBI, GCI, GHI, GSI, and GUI Maximum Maximum Installer BTU/Hr. Diameter of Equivalent Length Equivalent Length Provided Flue Flue Collar on Furnace Pipe Transition (ft. ) for 4" Vent Pipe (ft. ) for 5" Vent Pipe Size Diameters 45, 000 3" 3" to 4" 100 100 70, 000 3" 3" to 4" 100 100 90, 000 3" 3" to 4" 100 100 115, 000 4" None 85 95 140, 000 4" None 65 80 For Furnace Models GMI Installer BTU/Hr. Diameter of Provided Flue Flue Collar on Furnace Pipe Transition Size Diameters 40, 000 3" 3" to 4" 60, 000 4" None 80, 000 4" None 100, 000 4" None 120, 000 4" None 140, 000 4" None Maximum Maximum Equivalent Length Equivalent Length (ft. ) for 4" Vent Pipe (ft. ) for 5" Vent Pipe 100 100 100 100 80 60 100 100 100 100 90 80 General Wiring For complete installation information refer to the Field Controls SWG-4AM Power Venter Installation Manual for details (P/N 46333300. ) Page 3 SWG-4AT AMERICAN STANDARD AND TRANE SIDEWALL POWER VENTING KIT Field Controls P/N 46205405 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge For Use With The Following American Standard And Trane Furnaces: AUD-C TUD-C AUD-R TUD-R CUE-A TUE-A ADD-C TDD-C ADD-R TDD-R CDE-A TDE-A Furnace Configuration And Vent Pipe Restrictions: Furnace Input BTU/Hr 40, 000 60, 000 80, 000 100, 000 120, 000 140, 000 General Wiring Refer to the Diagrams on the following page for guidance in wiring the Power Venter and Control Kit to the appliance. [. . . ] 3"-to-4" increaser is required between vent pipe and power venter. General Wiring: For complete installation information refer to the Field Controls SWGII-4CC Power Venter Installation Manual for details (P/N 46295100. ) Page 9 SWG-4CD CONSOLIDATED SIDEWALL POWER VENTING KIT Field Controls P/N 46205408 Kit Includes: SWGII-4HD Sidewall Power Venter WMO-1 Thermal Safety Switch (Must be purchased separately if using other venting kit on Consolidated Furnaces. ) CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge For use with the following series of furnaces: This furnace was built by CONSOLIDATED INDUSTRIES under the names: QUATRO, TECH-4, QUADPRO, QUADTECH, MULTIFLOW, BRENTWOOD, and SUNBURST. Model Numbers: MAA040NR2R MBA040NH2R MCA040NR2R MDA040NH2R MAA040NR3R MBA040NH3R MCA040NR3R MDA040NH3R MAA060NR2R MBA060NH2R MCA060NR2R MDA060NH2R MAA060NR3R MBA060NH3R MCA060NR3R MDA060NH3R MAA060NR4R MBA060NH4R MCA060NR4R MDA060NH4R MAA080NR2R MBA080NH2R MCA080NR2R MDA080NH2R MAA080NR3R MBA080NH3R MCA080NR3R MDA080NH3R MAA080NR4R MBA080NH4R MCA080NR4R MDA080NH4R MAA080NR5R MBA080NH5R MCA080NR5R MDA080NH5R MAA100NR3R MBA100NH3R MCA100NR3R MDA100NH3R MAA100NR4R MBA100NH4R MCA100NR4R MDA100NH4R MAA100NR5R MBA100NH5R MCA100NR5R MDA100NH5R MAA120NR4R MBA120NH4R MCA120NR4R MDA120NH4R MAA120NR5R MBA120NH5R MCA120NR5R MDA120NH5R MAA140NR4R MBA140NH4R MCA140NR4R MDA140NH4R MAA140NR5R MBA140NH5R MCA140NR5R MDA140NH5R Note: Model numbers may have suffix "X". This kit may also be used with furnaces manufactured by Consolidated Industries and sold by a number of other companies under their names. This furnace was built by CONSOLIDATED INDUSTRIES under the name PREMIER. Model Numbers: HBA040NR3R HBA060NR4R HBA080NR4R HBA100NR5R HBA120NR5R Note: Model numbers may have suffix "X". This kit may also be used with furnaces manufactured by Consolidated Industries and sold by a number of other companies under their names. General Information: Page 10 1. 2. Maximum equivalent vent length is 63 feet for all furnaces listed!The SWG-4CD power venter kit must be installed using type B-1 vent pipe only! General Wiring For complete installation information refer to the Field Controls SWG-4CD Power Venter Installation Manual for details (P/N 46333600. ) SWG-4D DUNKIRK SIDEWALL POWER VENTING KIT Field Controls P/N 46205406 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43D Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Adjustable post purge For use with the Dunkirk Radiator Boiler Models XEB 2-5 or Equivalent* *To determine equivalent models, call (716)366-5500 and ask for Technical Service Department Unit Sizing and Equivalent Footage Max. Horizontal Vent Run 50'+ Tee with a 3"x4" increaser for the barometric draft control + 3"x4" increaser with power venter Min. Horizontal Vent Run 2'+ 90° elbow + tee with a 3"x4" increaser for the barometric draft control + 3"x4" increaser with power venter For additional elbows, reduce the maximum vent length as follows: Page 11 3" x 90° elbow - reduce vent length by 3 feet for each elbow Standard 3" single walled galvanized venting or 3" Type B vent pipe should be used. Install a 3" vent pipe tee of the same material as the vent piping 12" to 24" away from the outlet of the boiler's blower. Then place a 3"X4" reducer in the tee for mounting the barometric draft control as shown in the Figure below. Seal the vent pipe tee and reducer using the sealing and joining procedures in the boiler installation instructions. Seal the barometric draft control into the tee using the same high temperature silicone as used on the vent piping. The front face of the control MUST be plumb and the bearing surfaces MUST be level whether the control is on a horizontal, vertical, or sloping vent pipe. Use a spirit level and level accurately. Indicated 45, 000 and 67, 500 BTU furnaces must not be auxiliary power vented unless the original vent pressure switch is replace with a 0. 30 vent pressure switch, Rheem P/N 42-24064-01. Failure to replace the pressure switch as specified could lead to improper operation of the furnace resulting in property damage, personal injury, or death. Application & Installation Notes: 1. READ THE POWER VENTER APPLICATION & INSTALLATION INSTRUCTIONS VERY CAREFULLY BEFORE ATTEMPTING TO INSTALL AND/OR OPERATE THE POWER VENTER. Do not use this kit with HTPV or SVS vent pipe. [. . . ] All vent pipe and elbows must be Type B, double wall vent. The maximum vent length is 30 feet with a maximum of three 90° elbows. Use 3" vents for models with inputs through 75, 000 BTU/Hr. Use 4" vents for models with inputs over 75, 000 BTU/Hr. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46334200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46334200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag