If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS FORM42. We hope that this FIELD CONTROLS FORM42 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS FORM42.


Mode d'emploi FIELD CONTROLS FORM42
Download
Manual abstract: user guide FIELD CONTROLS FORM42

Detailed instructions for use are in the User's Guide.

[. . . ] If additional wiring is required, install the flexible conduit connector onto the installer supplied junction box. Fasten the flexible conduit from the SWG Venter into the conduit connector. Mount the CK-41P control box onto a non-heated vertical surface of the appliance or nearby wall or floor joist through the four dimpled locations on the base of the box. NOTE: The mounted pressure switch diaphragm must be mounted with a vertical orientation; see label on pressure switch. [. . . ] PRESSURE SWITCH SENSING TUBE INSTALLATION: 1. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. Connect installer supplied 1/4" O. D. aluminum, copper or stainless steel tubing to the tubing connector. Route the tubing to the CK-41F junction box and connect the tubing to the pressure switch using supplied plastic nut. When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. Support the tubing at 2' intervals using installer supplied tube clamps. PROVING SWITCH ADJUSTMENTS: After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Fig. Turn the adjustment screw counterclockwise until burner ignites. Turn the adjustment screw an additional 1/4 to 3/4 turn counterclockwise to ensure adequate switch adjustment. Adjust the thermostat and/or aquastat to call for heat and observe the power venting system for proper operation sequence. After a short delay, the relay is energized, the venter motor starts and the vent damper begins opening. Pressure switch closes, the vent damper reaches the open position and the burner starts. Aquastat is satisfied, the burner stops and the vent damper begins closing. While system is operating, disconnect power to the venter motor. This should open the pressure switch contacts and stop burner operation. Venter does not activate when thermostat calls for heat. Check wiring: 115 VAC from L1 to ground; N connected to a neutral. Check for 24V from orange to black wires on base of timer relay. If no other voltage, the appliance is not calling for heat to the CK-41P. [. . . ] If there is 24 volts continuously for at least 45 second, there should be 115 volts from N to M. If not, the time relay is defective, or L1 and N are not properly wired. Adjust power venter's airflow adjustment damper if necessary. Check for negative pressure in building. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS FORM42

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS FORM42 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag