Manual abstract: user guide FIRST ALERT FA148C3-00
Detailed instructions for use are in the User's Guide.
[. . . ] 6HFXULW\6\VWHP
)$ & ) $ & & 1
R
ARMED
READY
R
A B C D
1 OFF 4 MAX 7INSTANT
2 AWAY 5 TEST 8 CODE 0
3 STAY 6BYPASS 9 CHIME #
IIIIII
R
*
READY
FA560
HEAT
COOL
BYPASS
ACTIVE
8VHU*XLGH
K4855V1 3/00
TABLE OF CONTENTS
System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Zones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Burglary Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] All codes can be used interchangeably when performing system functions (a system armed with one user's code can be disarmed by another user's code), except the temporary code, described below.
Temporary Code
This code can be used to arm and disarm the system. It is typically assigned to someone (such as a babysitter) who needs to arm/disarm the system only at certain times. The temporary code is assigned to user 15. The user of this code should not use the Quick Arming feature described below. This code will automatically be removed when the Master code is entered.
Duress Code
This feature is intended for use when you are forced to disarm or arm the system under threat. When used, the system will operate normally, but can silently notify the alarm monitoring company of your situation, if that service has been provided. Important: This code is useful only when the system is connected to an alarm monitoring company.
- 29 -
Security Codes (cont'd)
Quick Arming
Note that if Quick Arming was programmed by the installer, you can press the # key in place of the security code when arming the system. You must always use the security code to disarm the system, however.
To Add a User or Change a User's Code
Important: Temporary users of the system (e. g. , babysitter, cleaning staff) should not be shown how to use any system function they do not need to know, such as bypassing protection zones.
You must make sequential key depressions for all steps in a procedure within 2 seconds of one another (e. g. , perform steps 1, 2, and 3 below with no delay between steps), or else the entire entry is aborted and must be repeated from its beginning. 1.
(Master Code)
+8
Enter 4-digit Master code, then press the 8 key. Example: Press 2 0 5 9 then 8
2.
(User Number)
Enter user number. Enter the 2-digit user number (03-16) for the user you are adding or changing. Enter the new 4-digit security code for that user.
3.
(User's Code)
Changing the Master Code
Follow the procedure for changing a user's code, but enter user 02. Additionally, when changing the Master code, you must perform step 3 twice with the same user code entry so that the new Master code will be accepted by the system.
- 30 -
Security Codes (cont'd)
To Delete a User
1.
(Master Code)
+8
Enter 4-digit Master code, then press the 8 key. Example: Press 2 0 5 9 then 8
2.
(User Number)
Enter user number. Enter the 2-digit user number (03-16) for the user whose code you are deleting. Wait (about 3 seconds) until the keypad beeps once before pressing any other key. The code is automatically deleted.
3. -----------
- 31 -
Testing the System
(To be conducted weekly)
Using the 5
TEST
Key
The TEST key puts your system into a TEST mode, which allows each protection point to be checked for proper operation. The keypad sounds a single beep every 30 seconds as a reminder that the system is in this TEST mode. NOTE: An alarm message will not be sent to your alarm monitoring company during the following tests. READY TO ARM Disarm the system and close all protected windows, doors, etc. The READY message should be displayed and the green READY indicator (if present on the keypad) should also be lit. [. . . ] 11, 26, 37 Fire Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Fire Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 23 Fixed Word Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9, 12 Fixed Word Keypad Display . . . . . . . . . . . . . . . . . . . . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRST ALERT FA148C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.