User manual FIRST ALERT FA2000C 7-96

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIRST ALERT FA2000C. We hope that this FIRST ALERT FA2000C user guide will be useful to you.

Lastmanuals help download the user guide FIRST ALERT FA2000C.


Mode d'emploi FIRST ALERT FA2000C
Download
Manual abstract: user guide FIRST ALERT FA2000C7-96

Detailed instructions for use are in the User's Guide.

[. . . ] Previous Menu USER'S MANUAL FA2000C Fire Alarm Control/Communicator N8028-1 7/96 TABLE OF CONTENTS SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Fire & Emergency Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Single digit zone numbers must be preceded by a zero. When finished, the keypad will momentarily display a "Bypass" message for each bypassed zone number. Wait for these zones to be displayed, to confirm their bypass. A bypass message is sent to the central station. All emergency zone bypasses are removed when an OFF sequence (user code plus OFF) is performed. TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONE BYPASS 03 FRONT UPSTAIRS STORAGE ALPHA 03 ALARM FIRE CHECK AWAY BYPASS STAY INSTANT SUPV NO AC PHONE TEST NOT READY CHIME BAT TAMPER FIXED-WORD 17 SUPERVISORY CONDITIONS General If your building has a fire sprinkler system, your installer may have installed a sensor which monitors the sprinkler system (e. g. , to determine whether the main water gate valve is open or that there is adequate water pressure, etc. ). Your system provides the following indications when a supervisory condition is detected. CALL YOUR INSTALLER IMMEDIATELY FOR SERVICE WHEN A SUPERVISORY INDICATION APPEARS! The control's buzzer and the keypad buzzer both produce a rapid on/off pulsing sound. The keypad LCD (Fixed-Word) displays the word "SUPV" and the number of the zone with the supervisory condition. Alpha keypads also display a description of the zone. SUPV 04 SPRINKLER VALVE ALPHA 04 AWAY ALARM STAY BYPASS SUPV NO AC PHONE TEST NOT READY CHIME BAT TAMPER FIRE CHECK INSTANT FIXED-WORD Silencing and Resetting a Supervisory Indication A supervisory message is sent to the central station. To reset the keypad supervisory To silence the control and keypad display: First have the cause of the buzzers: indication corrected, and then: Press the control's SILENCE/RESET button or enter your User Code, + the OFF key The keypad's LCD will display the number of the zone having the supervisory condition as a Memory indication. 18 Press the SILENCE/RESET button again or re-enter your User Code, followed by the OFF key. TROUBLE CONDITIONS General Your system monitors each of your protection zones and various aspects of system operation for problems such as wire breaks, loss of AC power, faulted telephone lines, etc. , which compromise proper alarm signaling operation. Your system provides the following indications when one of these problems is detected. CALL YOUR INSTALLER IMMEDIATELY FOR SERVICE, WHEN ANY OF THESE INDICATIONS APPEAR FOR A CONDITION THAT CANNOT BE CORRECTED BY YOU! The control's buzzer and keypad buzzer both produce a rapid pulsing sound. The controls AC POWER LED turns off and the keypad LCD displays "AC LOSS" (Alpha) or "NO AC" (Fixed-Word) when AC power is low or not present. The control's BATTERY TROUBLE LED lights and the keypad LCD displays "SYSTEM LO BAT" (Alpha) or "BAT" (Fixed-Word) when your system's back-up battery is low or disconnected. The controls COMM FAIL LED lights and the keypad LCD displays "COMM FAILURE" (Alpha) or "FC" (Fixed-Word) when attempts to send a message to the central station have failed. The keypad LCD (Fixed-Word) displays "CHECK" accompanied by a protection zone number (15) or system zone number (612) when there is a zone or system related problem. Alpha keypads also display a description of the zone. The control's LINE FAULT LED lights if the problem is with the telephone lines. CHECK 03 CHECK 01 FRONT UPSTAIRS STORAGE WAREHOUSE SMOKE ALPHA 03 ALARM FIRE CHECK AWAY BYPASS STAY INSTANT SUPV NO AC PHONE TEST NOT READY CHIME BAT TAMPER FIXED-WORD 19 TROUBLE CONDITIONS A trouble message is sent to the central station. Note: If your keypad LCD displays "0C" for more than 5 minutes, then it is not receiving signals from the control. [. . . ] Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. External fac tors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allowing time to arrange a change of battery to maintain protection for that given point within the system. Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRST ALERT FA2000C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIRST ALERT FA2000C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag