Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FLECK 5600SE. We hope that this FLECK 5600SE user guide will be useful to you.
Lastmanuals help download the user guide FLECK 5600SE.
Detailed instructions for use are in the User's Guide.
[. . . ] Model 5600SE Downflow
Service Manual
IMPORTANT: Fill in pertinent information on page 3 for future reference.
Model 5600SE Downflow
Table of Contents
Job Specification Sheet . 3 General Residential Installation Check List . 4 Valve Installation and Start-up Procedures . 10 Immediate Regeneration Valves with Days Between Regeneration Override Set . [. . . ] Remove the two injector body mounting screws. The injector and brine module can now be removed from the control valve. Remove and discard brine body o-rings.
Brine Valve Replacement
1. Also remove and discard o-ring at bottom of brine valve hole. Apply silicone lubricant to new o-ring and reinstall at bottom of brine valve hole. Apply silicone lubricant to o-ring on new valve assembly and press into brine valve hole. Be sure shoulder on bushing is flush with injector body.
Injectors/Screen Replacement
1. Remove injector cap and screen, discard o-ring. Unscrew injector nozzle and throat from injector body. Screw in new injector throat and nozzle, be sure they are sealed tightly. Apply silicone lubricant to new o-ring and install around oval extension on injector cap. Apply silicone lubricant to three new o-rings and install over three bosses on injector body. Insert screws thorough injector cap and injector. Place this assembly thorough hole in timer housing and into mating holes in the valve body. Return bypass or inlet valving to normal In Service position. Water pressure automatically builds in the conditioner. NOTE: Be sure to shut off any bypass line. Check drain seal with the control in the Backwash position. Plug electrical cord into outlet.
10. Set Time Of Day and cycle the control valve manually to assure proper function. Make sure control valve is returned to the In Service position. Be sure there is enough salt in the brine tank. [. . . ] Reprogram the control to the proper regeneration type, inlet water hardness, capacity or flow meter size. Clean control and add resin cleaner to resin bed. Assure that well system has proper air eliminator control check for dry well condition. Ensure drain line flow control is sized correctly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FLECK 5600SE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLECK 5600SE will begin.