[. . . ] Operation and Maintenance Manual
GB-75TM and GB-152TM Gas Booster With Control Kit
©1998-2008 DH Instruments, a Fluke Company
GB-75TM AND GB-152TM OPERATION AND MAINTENANCE MANUAL
This equipment described in this manual is designed and manufactured for the intended purpose of generating high pressure gas. Certain precautions need to be followed during installation and operation of this device. Reading and understanding the material is essential to the safe and correct operation of the unit.
Pressurized equipment is potentially dangerous. The equipment described in this manual generates and controls very high gas pressures. [. . . ] Remember that when the SHUTOFF valve is in the ON position, the booster will operate until the high pressure output is equal to the drive air setting times the booster ratio. The DRIVE ADJUST regulator is NOT self venting so it cannot be used to set pressure lower than the current pressure when the SHUTOFF valve is OFF. If you overshoot the desired set point, set the SHUTOFF valve to ON until the DRIVE pressure is lower than your desired setting. Then set the SHUTOFF valve to OFF and use the regulator to adjust the pressure in the ascending direction. Generate high pressure: Set the SHUTOFF valve to the ON position. The booster will begin to cycle and will continue to cycle until it stalls. When it stalls, the high pressure output is roughly equal to the drive pressure setting times the booster's ratio (75 or 152).
©1998-2008 DH Instruments, a Fluke Company
Page 12
3. OPERATION
3.
3. 1
OPERATION
GENERAL OPERATING PRINCIPLE AND INFORMATION
Refer to Figure 3.
The purpose of the GB booster is to automatically boost gas pressure to very high pressure. The value of very high pressure that is generated depends on the drive air pressure setting. The unit generates high pressure using a Pneumatically Operated Gas Booster Pump and a Drive Air Control Kit. GAS BOOSTER PUMP The booster pump is a Pascal press utilizing two pistons connected together on the same axis having a normal area ratio of 75:1 (GB-75) or 152:1 (GB-152). The booster is a two-stroke, single stage reciprocating pump that generates gas pressures 75 or 152 times greater than the shop drive air applied to the pump. The pump operates automatically, provided drive air is supplied to the DRIVE ADJUST regulator and the regulator is set to at least 140 kPa (20 psig). Operation is continuous until the outlet pressure is 75 (GB-75) or 152 (GB-152) times the shop drive air pressure. At this point, the opposing forces within the pump reach equilibrium and the pump stalls. For example, using a GB-75 with the drive air pressure set to 500 kPa (73 psig), the pump will run until the high pressure output reaches 75 x 0. 5 = 37. 5 MPa (5 450 psig). The Shop Drive Air section (low pressure) consists of a piston, cylinder, air cycling valve, pilot valve and vent section. This section provides the reciprocating action and compression force needed to operate the booster and generate the high pressure gas. Drive air is channeled to the appropriate side of the piston (compression or suction stroke) by the air cycling valve. When the piston reaches full stroke, a pilot valve is mechanically activated causing the air cycling valve to change position. Shop drive air is routed to the opposite side of the piston reversing piston direction where a second pilot valve is activated repeating the process. The high pressure section (high pressure) consists of a small piston and an inlet/outlet check valve assembly. [. . . ] Increase drive air pressure, using the DRIVE ADJUST regulator, to about 500 kPa (75 psi). Put the drive air SHUTOFF valve into the ON position quickly. If the booster begins to operate normally, set the drive air SHUTOFF valve to OFF and reset the regulator to previous settings. Repeat the process until the booster begins normal operation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE GB-152 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE GB-152 will begin.