If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FLUKE MULTIMETER WITH TEMPERATURE 16. We hope that this FLUKE MULTIMETER WITH TEMPERATURE 16 user guide will be useful to you.

Lastmanuals help download the user guide FLUKE MULTIMETER WITH TEMPERATURE 16.


Mode d'emploi FLUKE MULTIMETER WITH TEMPERATURE 16
Download
Manual abstract: user guide FLUKE MULTIMETER WITH TEMPERATURE 16

Detailed instructions for use are in the User's Guide.

[. . . ] Press button to switch between modes. Double insulation. Manual ranging mode. ip14i. eps Automatic Range Selection The meter defaults to autoranging when you turn it on. The 4000 mV range can be entered only with manual range selection. Manual Range Selection 16 MULTIMETER OFF CAT 600V COM + To return to autoranging, press for 2 seconds, or change the measurement mode. ip15i. eps Battery Saver If the meter is ON but inactive and not connected to voltage for more than 45 minutes, the display goes blank to preserve battery life. [. . . ] Push select button 3 times to select µA. Connect meter between flame sensor probe and control module. Turn heating unit on and record µA measurement. Diode Test G Turn off circuit power before testing. For best results diodes should be measured out of circuit. Also refer to V·Check. Good Diode 16 MULTIMETER Typical voltage for silicon diode 16 MULTIMETER Low Impedance V·Check OFF A CAT V·Check OFF A CAT V·Check 600V TEMPERATURE 600V TEMPERATURE COM + COM + Single beep ip03i. eps Forward Bias Bad Diode 16 MULTIMETER Reverse Bias 16 MULTIMETER OFF A CAT V·Check OFF A CAT V·Check 600V TEMPERATURE 600V TEMPERATURE COM + COM + or ip04i. eps Shorted Open MIN MAX µF (Records the lowest and highest measurements) V·Check, autoranging, and Battery Saver are disabled. Put the meter in the proper range before entering MIN MAX. When the reading changes more than about 50 digits, the meter gives a short beep. When a new minimum or maximum is recorded, the meter gives a long beep. Enter Present Reading with MIN MAX Input Change Alert TM Maximum Reading 2 sec To Exit Minimum Reading ip10i. eps MIN MAX with Elapsed Time µF Records the hours and minutes between when MIN MAX was entered and the last high and low was recorded. OL is displayed for times longer than 99:59. To enable the MIN MAX timer, hold down M while turning the rotary switch from OFF to either measurement mode. Enter MIN MAX. View Present Reading Maximum Reading Maximum Reading Elapsed Time 2 sec Minimum Reading Elapsed Time Minimum Reading Exit MIN MAX ip11i. eps To disable the beeper for all modes, hold down r for 2 seconds while turning the meter on. Disabling the Beeper Continuity Capture To set up the meter to capture intermittent shorts and opens, turn the switch to GR, connect the leads to the circuit; then press M. ip12i. eps Captures transitions longer than 250 µs (1/4000th of a second). Transitions after the first transition cause the meter to beep, but the display does not change. To reset the display to the current condition, press M. To exit, press M for 2 seconds, or change the measurement mode. Maintenance Clean the case with a damp cloth and detergent. Battery Replacement Remove the test leads before disassembling the case. Replacement Parts Fluke TL-75 (Double-insulated leads) PN 855705 80BK (Integrated Temperature Probe) PN 1273124 Service and Parts This meter should be serviced only by a qualified service technician. To locate an authorized service center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www. fluke. com. C O M 60 0V + + ip13i. eps Specifications Accuracy is specified for a period of one year after calibration, at 18°C to 28°C (64°F to 82°F) with relative humidity to 90%. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ±([% of reading] + [number of least significant digits]) Function Temperature Range -10°C to 400°C 14°F to 752°F Resolution 0. 1°C or 0. 2°F 0. 1°C or 0. 2°F Accuracy ±(1. 0% + 0. 8°C) typical ±(1. 0% + 1. 5°F) typical ±(5. 0% + 1. 5°C) typical ±(5. 0% + 3. 3°F) typical Accuracy (Type K Thermocouple) -40°C to -10°C -40°F to 14°F Error does not include Type K Thermocouple errors. [. . . ] The warranty period is three years and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE MULTIMETER WITH TEMPERATURE 16

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE MULTIMETER WITH TEMPERATURE 16 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag