User manual FLUKE RPM4-AD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FLUKE RPM4-AD. We hope that this FLUKE RPM4-AD user guide will be useful to you.

Lastmanuals help download the user guide FLUKE RPM4-AD.


Mode d'emploi FLUKE RPM4-AD
Download
Manual abstract: user guide FLUKE RPM4-AD

Detailed instructions for use are in the User's Guide.

[. . . ] RPM4-ADTM Reference Pressure Monitor, Air Data Version Operation and Maintenance Manual © 2005-2007 DH Instruments, a Fluke Company High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. This instrument is not to be operated in any other manner than that specified by the manufacturer. © 2005-2007 DH Instruments, a Fluke Company All rights reserved. Information in this document is subject to change without notice. [. . . ] This is the most commonly used air speed unit. Select <2true> for airspeed calculated from differential pressure (Qc) taking into consideration altitude (Ps) and a user entered temperature value. Airspeed type: 1calibrated 2true If <2true> is selected, the default air temperature to be used in calculating airspeed must be entered. The display is: True airspeed default T: 15. 0 ºC 1. Entry field for default temperature to be used in true airspeed calculation. The default value is 15 ºC. Enter the default temperature value. This value can be edited when a true airspeed unit is selected in the [UNIT] menu. Changing this value changes the default temperature value for any true airspeed units that have already been setup. In RPM4-AD displays, calibrated airspeed units are represented in lower case (e. g. kts) and true airspeed units are represented in upper case (e. g. KTS). If <4user> is selected, the user unit must be defined. The display is: Define user unit: 1. 000000 unit/Pa 1. Entry field. Enter the number of user units per Pascal (Pa) in the entry field. Pressing [ENT] defines the user unit and returns to the <Set up unit #n> screen. The user defined unit label can be customized to any alphanumeric, four character label using the remote command "UDU" (see Section 4. 4. 4). See Section 7. 2 for information on the unit of measure conversions used by RPM4-AD. © 2005-2007 DH Instruments, a Fluke Company Page 72 3. OPERATION OPERATION WITH RPM4 A350K/A160K To customize the [UNIT] function key, press [SPECIAL], <6PresU> from the MAIN RUN screen. The display is: Select the Q-RPT for which the UNIT function menu is being customized. The next display is: Setup UNIT for Q-RPT 1Hi 2Lo 1. Q-RPT for which UNIT function menu is being customized. Measurement mode: Hi 1absolute 2other Select the measurement mode for which the UNIT function key menu is being customized. 1. Entry field to specify which unit position (1 to 6) of the UNIT function menu is to be changed. Set up unit #6 for Hi absolute mode Enter the number of the unit position on the UNIT function menu that you would like to change. The next display lists the type of measurement units supported by RPM4-AD. <SI> and <other> are pressure units. Unit#6 1SI 2other 3altitude 4airspeed 5user See Table 15 for definition of unit type availability by Q-RPT and measurement mode. If the measurement unit type selected is not available for the selected Q-RPT and/or measurement mode, <Not available on [Q-RPT], [measurement mode]> is displayed. Press [ESC] to return to the unit type selection screen and select a valid unit type. Table 15. Available unit of measure types by active Q-RPT and measurement mode, RPM4-AD A350K/A160K (fixed wing) Q-RPT MEASUREMENT MODE Absolute <a> Gauge, negative gauge <g> Absolute <a> Gauge, negative gauge <g>, differential <d> UNIT TYPE PRESSURE Yes Yes Yes Yes ALTITUDE Yes No No No 1 AIRSPEED No No No Yes 1 USER Yes Yes Yes Yes Lo <Lo> Hi <Hi>, <Hd> 1. Altitude measured by Lo Q-RPT can be displayed while measuring airspeed. After selecting the unit type, select the unit. [. . . ] Pressure controller calibrator manufactured by DHI. RPM4-AD can be used as an external reference device for a PPC3. PPC3 automates RPM4-AD pressure control. The transducer used by RPM4-AD for low uncertainty pressure measurement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE RPM4-AD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE RPM4-AD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag