User manual FLUSHMATE 501

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FLUSHMATE 501. We hope that this FLUSHMATE 501 user guide will be useful to you.

Lastmanuals help download the user guide FLUSHMATE 501.


Mode d'emploi FLUSHMATE 501
Download
Manual abstract: user guide FLUSHMATE 501

Detailed instructions for use are in the User's Guide.

[. . . ] Please follow the instructions provided by the fixture manufacturer. Using the gasket, washer and nuts provided with the fixture, assemble the tank to the bowl. Before connecting the supply to the tank, be sure the supply line is flushed clean. Do this by running water from the supply stop into a bucket until water flows clear. [. . . ] If the water stops running, it is an indication that the Flush Valve Cartridge requires tightening (clockwise). If water still runs on while pushing down on the Actuator, the Flush Valve Cartridge requires loosening (counter-clockwise). NOTE: Adjust the Flush Valve Cartridge Assembly in quarter- to half-turn increments until the water stops running. Always turn the water supply off for all adjustments. Flush Valve Cartridge turns the water off. If replacement of the Flush Valve Cartridge is necessary, follow the instructions in Step 5. TROUBLESHOOTING _____________________________________________________________ CONDITION: Weak or Sluggish Flush. Check the water pressure (20psi - 125psi recommended). If OK, then check the Flush System by removing the Tank Cover and tripping the Actuator. While the unit is flushing, gently raise the Actuator. Water should flow freely and wash away any debris in the supply line and Vessel. Check the Air Inducer for sufficient air draw. Check the water pressure (20 psi to 125 psi). Check the Air Inducer for sufficient air draw. Refer to Step 2 of "Weak or Sluggish Flush". Review all of Step 3 and Step 4 covered in "Weak or Sluggish Flush" Condition. NEVER use lubricant on the "O" Ring (Arrow - Figure 6). FIGURE 6 CONDITION: Relief Valve Discharging This is a sign that the Lower Supply Group (Number 1 from list of components) is not working properly and should be replaced. Follow the procedure outlined below: REPLACE PROCEDURE FOR LOWER SUPPLY: Step1. Flush the fixture to relieve pressure in the vessel and disconnect the water supply from the shank. Remove the China Tank from the China Bowl by removing the nuts/washers or wings nuts from the bottom of the China Tank. Unscrew the plastic locknut that holds the shank to the bottom of the China Tank and remove the tank to bowl gasket. Unscrew the plastic nut that holds the vessel to the bottom of the China Tank and carefully remove the entire vessel from the China Tank. Remove the Lower Supply Assembly by pulling in a downward motion. [. . . ] However, if servicing is ever required, it is recommended that you follow the instructions included in this brochure. If you would like additional information or require technical assistance, write or call us at the address or telephone number below. ATTENTION OWNER THIS IS YOUR WARRANTY REGISTRATION Sloan FLUSHMATE (the "Company") warrants the FLUSHMATE® flushometer tank operating system (the "unit") to be free of defects in material and workmanship for a period of two (2) years from the date of installation and the Company promises to replace any part of this product that proves, upon our inspection and within two (2) years from date of installation, to be defective in material or workmanship. All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser-user. This warranty is subject to the following: Specific Conditions to Warranty A Warranty Registration card has been fully completed and mailed by the purchaser (the "user") to the Company within thirty (30) days of the date of installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUSHMATE 501

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUSHMATE 501 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag