[. . . ] NEVER use lubricants on any of the components unless otherwise noted in this manual. NEVER use corrosive chemicals or household cleaners on FLUSHMATE ® products. Note: It is normal for less than one inch of water to remain in the bottom of the china tank.
INSTALLATION __________________________________________________________________
The Sloan FLUSHMATE ® Flushometer-Tank System Fixture installs in the same manner as other water closets. Please follow the instructions provided by the fixture manufacturer. [. . . ] If OK, then check the Flush System by removing the Tank Cover and tripping the Actuator. While the unit is flushing, gently raise the Actuator. Water should flow freely and wash away any debris in the supply line and Vessel. Check the Air Inducer for sufficient air draw. The air inducer is designed to draw air during the refill cycle. To test the Air Inducer, place a small amount of water (2 to 3 drops) in the orifice of the air inducer cap and flush the toilet. If the air inducer is functioning properly the water will be drawn in. If not, it will need to be cleaned and tested again. TO CLEAN AIR INDUCER: (Figures 3 & 4) a) Turn off the water supply and trip the Actuator. b) Unscrew the Air Inducer Cap, clean thoroughly and remove any obstructions. (Hand tighten ONLY) c) Turn on water supply. Wait for the Vessel to refill (30 to 60 seconds). If the Air Inducer does not function properly, replace the Upper Supply Assembly. Check the Flush Valve Cartridge for leaks. Turn the water supply off and drain the Vessel by tripping the Actuator and holding it down until completely drained. Next, pour a cup of water onto the Cartridge Housing area as shown in Figure 5. If a leak is detected (a steady flow of bubbles from the center of the Cartridge Area), the Cartridge should be replaced. Turn the water off and relieve the Vessel pressure by flushing the toilet. Remove the supply line connection to the shank. Remove any obstruction in the supply shank screen. If necessary, you can use a small brush to gently brush the screen. Reattach the supply line to the supply shank and observe connections to assure no leakage. [. . . ] The FLUSHMATE System will automatically recirculate this water with each flush to eliminate any stagnant condition. · NEVER use corrosive disinfectants, bowl cleaners or deodorant blocks on FLUSHMATE ® Products or in the china tank. The Sloan FLUSHMATE ® Flushometer-Tank System has been engineered to provide reliable performance year after year. However, if servicing is ever required, it is recommended that you follow the instructions included in this brochure. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUSHMATE 501B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUSHMATE 501B will begin.