Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FOSTEX PM0.5 MK2. We hope that this FOSTEX PM0.5 MK2 user guide will be useful to you.
Lastmanuals help download the user guide FOSTEX PM0.5 MK2.
Detailed instructions for use are in the User's Guide.
[. . . ] Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installation, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. [. . . ] Main plug is used as the disconnection device. It shall remain readily operable and should not be obstructed during intended use. To be completely disconnected the apparatus from supply mains, the mains plug of the apparatus shall be disconnected from the mains socket outlet completely.
p-2
Introduction
Thank you for purchasing the Fostex PM0. 5 MK Professional Studio Monitor. As with all Fostex products, the PM0. 5 MK has been designed to provide superlative performance, unquestioned reliability and exceptionally high value. The PM0. 5 MK was specifically engineered to fulfill all of your critical near-field monitoring needs and is emblematic of the years of experience Fostex has had in the professional audio marketplace. The PM0. 5 MK takes full advantage of internal bi-amplification and employs two state of the art amplifiers that utilize highquality discrete bipolar output devices. The 5 ½" woofer and 1" tweeter were expressly designed for high output, ultra low distortion and incorporate the latest technologies and manufacturing techniques. Please take the time to thoroughly read this manual so that you may take full advantage of all the benefits of the Fostex PM0. 5 MK Professional Studio Monitor.
Unpacking
Prior to unpacking your Fostex PM0. 5 MK Studio Monitor, carefully inspect the packing material for excessive damage. Once it has been determined that the packing material has not been compromised, carefully unpack the PM0. 5 MK Studio Monitor and inspect it carefully for obvious damage. Fostex takes great care in designing packing materials that will survive most expected impacts during shipping. If any damage is discovered during the inspection process, contact your Fostex dealer so that this issue can immediately be addressed.
p-3
Setup Instructions
Monitoring Distance = 1 to 2 meters After carefully unpacking the PM0. 5 MK Professional Studio Monitor, it is now time to setup the monitors for the best acoustic performance in your studio. The PM0. 5 MK was designed to be used at a monitoring distance of 1 to 2 meters, typically referred to as the near-field. Monitoring Height = the acoustic center aimed at seated ear height It is recommended that the PM0. 5 MK be located in such a way that the acoustic center is located at, or about, seated ear height (see Figure 1). If this is not possible, it may be necessary to tilt/aim the monitor at the listeners ears. Monitoring Angle = 60 Degrees The monitoring angle between the left and right monitors and the listening position should equal 60 degrees. The easiest way to determine this is to place the speakers in such a way that the distance between the left and right monitor is equal to the monitoring distance / listening position (see Figure 2). It is also recommended that both speakers be "toed-in" towards the listening position. Additional Information The PM0. 5 MK was designed to be mounted vertically. This provides for the most accurate frequency response, reduces acoustic boundary interference and provides optimum cooling performance for the heat sink that is located on the back of the studio monitor. If it is not possible to mount the monitors vertically, then the monitors should be placed with the woofers inside and the monitors "toed-in" towards the listening area.
Figure 2
B
Figure 1
Center of the tweeter
Center of the woofer Mid-point of the woofer and tweeter
Left
Right
D=
B
30° =B
Reference listening position
B: loudspeaker base width D: monitoring distance
p-4
Setup Instructions continued
Once the studio monitors have been placed in their final location, it is time to proceed to connecting your PM0. 5 MK studio monitors to the mixing console or digital workstation. Connection to the PM0. 5 MK can be made using XLR or TRS connectors. The gain control on the back of the monitor allows continuously variable adjustments to match most input types from -10dBV to +4dBu. [. . . ] ADD: 6 Zaimi Street, Exarchia, 106. 83 Athens, Greece TEL: (+30) 210-3809-605, 606, 607, 608 FAX: (+30) 210-3845-755, 210-3827-868 NAME: I. Electronics ADD: Gresa'svegur 12, 108 Reykjavi'k, Iceland TEL: (+354) 553-3050, FAX: (+354) 553-3435 NAME: Proel S. ADD: Zona Via Alla Ruenia, 37/43 64027-Sant'Omero (Teramo), Italy TEL: (+ 39) 0861-81241, FAX: (+39) 0861-887862 NAME: IEMKE ROOS AUDIO B. ADD: Kuiperbergweg 20, 1101 AG Amsterdam, The Netherlands TEL: (+31) 20-697-2121, FAX: (+31) 20-697-4201
<BELGIUM>
<THE NETHERLANDS>
<DENMARK>
<FINLAND>
<NORWAY> NAME: Siv. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX PM0.5 MK2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX PM0.5 MK2 will begin.