[. . . ] SDX-450V/P SDX-450V/RP 5. 25"Model
Product Specification Manual Version 1. 0
Sep. 2004
Copyright © 2004 Sony Corporation. NOTE: This Product Specification Manual is applicable for AIT-1 Turbo drive.
Notice
This document contains proprietary information which is protected by copyright. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of Sony. [. . . ] This command completes with Good status; however the new partition will be an empty partition. After this command completes, Unit Attention condition is set for other Initiators, with ASC/ASCQ set to 2A01, Mode Parameters changed. After this command, Mode Sense Page 11h will show the following: P0=2GB P1=20GB (old data) + 3GB = 23 GB <--- new append partition. Case 3. 3: AIT mode tape with two partitions. Mode Select Page 32h Append Partition Page indicates 2 GB for the partition size. This command completes with Good status, and the Unit Attention condition is set for other Initiators, with ASC/ASCQ set to 2A01, Mode Parameters changed. After this command, Mode Sense Page 11h will show the following: P0=2GB P1=20GB (old data) + 2GB = 22 GB <--- new append partition. Note 4: After partition appended, the Last Partition Number field of Volume Information in MIC indicates a valid value, while the value in the Last Partition Number field of Volume Information on tape is not valid. Note 5: The Append Partition Page operation is not allowed when the WP tab is set. Note 6: Append Partition Page writes all buffered data to tape, before appending a partition.
SONY AIT-1 Turbo drive SDX-450V series Ver. 1. 0
6-53
6. Command Specification
MODE SELECT
6. 7. 9. Delete Partition (33h)
Table 6-44: Delete Partition Page Bit Byte 0 1 2 3 4 5 6 7 8 9 7 Reserved 6 5 4 3 2 1 0
Page Code (33h) Page Length (8) Indicated Partition Number Reserved Reserved Reserved Reserved Reserved Reserved Reserved
SDX-450V rewind the tape to Bottom of Active Partition, after Delete Partition. Note 1: The Delete Partition Command is available in the AIT mode and only for an AIT mode cassette. Note 2: The Indicated Partition Number value specifies the partition number ABOVE which partitions are to be deleted. Consequently, the value cannot represent the last, open-ended partition on tape. The specified partition itself is converted into an open-ended partition with its data contents preserved. Note 3: Delete Partition is System area in the Active partition. Examples: Case 1 (with PRTH=0); With the tape already loaded, and with partition 5 active, the Delete Partition command issued with the Indicated partition Number set to 5 (the last partition) will be rejected with CHECK CONDITION (Illegal parameter). See Notes 2 and 3.
Indicated Partition Number Partition 0 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Active Partition
6-54
SONY AIT-1 Turbo drive SDX-450V series Ver. 1. 0
MODE SELSECT Case 2 (with PRTH=0);
6. Command Specification
With the tape already loaded, and with partition 4 active, the Delete Partition command issued with the Indicated Partition Number set to 4 will delete partition 5. SDX-450V will change the value of 5 in the Last Partition Number field in the Volume Information in MIC to 4. The new last partition - partition 4 - will become open-ended, spanning up to the OEM. After the completion of this command, the Unit Attention condition will be set for other Initiators, with ASC/ASCQ set to 2A01, Mode Parameters changed, and Mode Sense Page 11h will show the following: Old tape layout:
Indicated Partition Number Partition 0 Partition 1 Partition 2 Partition 3 Partition 4 Partition 5
Active Partition
New tape layout:
Partition 0 Partition 1 Partition 2 Partition 3 Partition 4 Active Partition
Case 3 (with PRTH=0); With the tape already loaded, and with partition 0 active, the Delete Partition command issued with the Indicated Partition Number set to 0 will delete partitions 1, 2, 3, 4, and 5. SDX-450V will change the value of 5 in the Last Partition Number field in the Volume Information in MIC to 0. [. . . ] Over Length: The incorrect length condition that exists after executing a read command when the length of the actual block read exceeds the requested transfer length in the command descriptor block. Only the requested amount of data is returned to the host. Partition: The entire usable region of recording and reading paths in a volume or in a portion of a volume. If there is more than one partition, they shall be numbered starting with ZERO (i. e. , beginning of partition ZERO). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FREECOM AIT-SDX450 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FREECOM AIT-SDX450 will begin.