User manual FRIGIDAIRE PL30WC4IEC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FRIGIDAIRE PL30WC4IEC. We hope that this FRIGIDAIRE PL30WC4IEC user guide will be useful to you.

Lastmanuals help download the user guide FRIGIDAIRE PL30WC4IEC.


Mode d'emploi FRIGIDAIRE PL30WC4IEC
Download

You may also download the following manuals related to this product:

   FRIGIDAIRE PL30WC4IEC INSTALLATION (1158 ko)

Manual abstract: user guide FRIGIDAIRE PL30WC4IEC

Detailed instructions for use are in the User's Guide.

[. . . ] PROFESSIONAL SERIES MODELS PL30WC4IEC PL36WC4IEC GALLERY SERIES MODELS GL30WC4IES GL36WC4IES GL30WC4IEB GL36WC4IEB Patent No. : US D450, 829 S READ AND SAVE THESE INSTRUCTIONS ! WARNING FOR DOMESTIC COOKING ONLY CAUTION ! ! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. [. . . ] 7" Round Ducted Discharge Only: Re-install 7" Round Duct Plate removed in Step #1 under "PREPARE THE HOOD". Install a 7" round damper (purchase separately). Damper flap must open freely in direction of airflow (away from range hood). SCREW TIES To accomodate off-center ductwork, the Damper/Duct Connector can be installed up to 1-inch on either side of hood center or the 7" Round Duct Plate can be installed up to ½" on either side of hood center. In extreme off-center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp. NOTE RETAINING BLOWER WHEEL RING TAB SMALL DIAMETER END SECTIONS METAL STRIP 12 PLATE 15 MOTOR STOP SLOTS EDGE Non-Ducted Installations Only: Require a Performance Ring to be attached to the blower wheel. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Slide the ring onto the Small Diameter End of the wheel and down to the Stop Edge of the wheel. Make sure Tab on wheel fits into one of the Motor Slots. Push wheel down until it is locked in place. Check that wheel is properly positioned as shown. Make sure wheel turns freely. Horizontal Discharge Only: Remove the Plate in front of the horizontal discharge knockout. Cut the Ties, lift plate out, and discard plate. DO NOT REMOVE the Metal Strip held in place with two Screws. 4 RING CONNECT WIRING WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally. INSTALL HOOD HOUSE WIRING (120 VAC) KEYHOLE (4) 1 CARDBOARD (Use to protect cooktop) 2 1 Connect House Wiring (120 VAC) to hood. Use a piece of Cardboard to protect the cooktop, if necessary. MOUNTING SCREW (4) Hang hood from (4) Mounting Screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) Keyholes. Replace bottom cover. DUCT TAPE 3 GREEN GROUND SCREW Connect ductwork to hood. Use Duct Tape to make joints secure and air tight. 2 Connect house black to hood black wire, house white to hood white wire, and house ground under Green Ground Screw. Securely tighten cable clamp onto house wiring. PAR20, 50W MAX. INCANDESCENT BULB (2) 4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately. ! 5 5 CAUTION: Bulbs may be hot!Refer to bulb packaging for further information. Replace filters, turn on power at service panel, and test for proper operation. NON-DUCTED FILTERS If hood is to be installed Non-Ducted: Purchase a set of (2) Non-Ducted Filters from your local distributor or retailer and attach them to the aluminum mesh filters. [. . . ] Food loss due to any refrigerator or freezer failures. Service calls which do not involve malfunction or defects in materials or workmanship, or for appliances not in ordinary household use or used other than in accordance with the provided instructions. Service calls to correct the installation of your appliance or to instruct you how to use your appliance. Expenses for making the appliance accessible for servicing, such as removal of trim, cupboards, shelves, etc. , which are not a part of the appliance when it is shipped from the factory. 10. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIGIDAIRE PL30WC4IEC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIGIDAIRE PL30WC4IEC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag