[. . . ] OPERATING MANUAL
ROOM AIR CONDITIONER
CEILING WALL TYPE HEAT & COOL MODEL (REVERSE CYCLE)
Indoor Unit
AWTZ24LBC
Outdoor Unit
AOTZ24LBT
REFRIGERANT
This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil.
R410A
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL. Refer to Commonwealth, State, Territory and local legislation, regulations, codes, installation & operation manuals, before the installation, maintenance and/or service of this product.
KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
P/N9315236029-01
CONTENTS
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES AND FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 NAME OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] During dry mode The airflow can not be set during HI-POWER operation During fan mode The airflow from the Indoor Unit is increased.
13
COIL DRY OPERATION
After allowing the interior of the indoor unit time to dry, run the UV filter clean, to limit mold and bacteria on the interior of the unit and on the air filter. This function shows clear results after cooling or dehumidifying. For COLID DRY Operation, press the COIL DRY button. Cleaning operations will run for about 20 minutes and stop automatically.
To start COIL DRY Operation Press the COIL DRY button (Fig. 5 a) (when the air conditioner is operating or stopped).
Only the OPERATION Indicator Lamp (red) (Fig2. "COIL DRY" appears on the Remote Control Unit display and disappears after approximately 20 minutes. a) is pressed again during COIL DRY operation, COIL DRY operation will start again.
NOTE!
When COIL DRY operation begins, the Indoor Unit operates in the heating mode and the fan mode to dry the inside of the Indoor Unit. As a result, the room temperature and humidity may rise slightly. COIL DRY operation cannot be used to clean the air in the room. COIL DRY operation is most effective when performed frequently.
To stop COIL DRY Operation Press the START/STOP button (Fig. 5 W) during COIL DRY operation.
The OPERATION Indicator Lamp (red) (Fig2. The Remote Control Unit will be in the operation-stopped condition.
About COIL DRY Operation
The following procedures are performed during COIL DRY operation before the operation automatically stops after approximately 20 minutes. 1 Drying After about 18 minutes of COIL DRY Operation, drying shall be performed on the interior of the indoor unit. All dirt and foul odors are to be removed from the air filter. 2 UV filter cleaning (about 2 minutes) UV rays are discharged onto the air filter, so that all dirt, odor, and dust undergo disinfecting and deodorizing processing, and are recycled into the dust box. At the same time, the air filter's disinfecting and deodorizing functions are reset, and returned to cleaning mode. 3 Operations stop The COIL DRY operation come to an end.
14
AUTO FILTER MAINTENANCE FUNCTION
This is a convenient function that automatically removes dust from the air filters after a set amount of time of air conditioner operation. The auto filter maintenance function can also be started using the remote control unit.
Auto Filter Maintenance
About operating the Auto Filter Maintenance
Auto filter maintenance is performed after the air conditioner operates for a set amount of time and is stopped or the FILTER button (Fig. 5 b) on the Remote Control Unit is pressed. During auto filter maintenance, the MAINTENANCE SIGN Indicator Lamp (red) (Fig. 2 4) on the Indoor Unit will light.
CAUTION!
Do not touch the air filters during the auto filter maintenance. The Indoor Unit may malfunction if the air filters are pulled or pushed. If the air filters are unnecessarily pulled, they may be damaged or fall and cause personal injury.
1. Air filters come out
The air filters automatically come out of the indoor unit under the open panel. At this time, the dust on the air filters is collected in the dust boxes (behind the open panel).
Open panel
2. Air filter retract
After the air filters come out, they automatically retract to their original positions in the Indoor Unit.
When the auto filter maintenance is complete, the MAINTENANCE SIGN Indicator Lamp (red) (Fig. 2 4) on the Indoor Unit goes out.
MAINTENANCE SIGN Indicator Lamp(red) flashes
The MAINTENANCE SIGN Indicator Lamp (Fig. 2 4) will flash during auto filter maintenance if the air filters are not Installed or are pulled. [. . . ] Is the unit set for SUPER QUIET operation?The unit operates differently from the Remote Control Unit's setting: Are the Remote Control Unit's batteries dead? Are the Remote Control Unit's batteries loaded properly?6 7 -- 11 - 12 -- See Page
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (red) (Fig. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FUJITSU AOTZ24LBT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.