User manual FUJITSU AOYR24LCCSERVICE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FUJITSU AOYR24LCCSERVICE. We hope that this FUJITSU AOYR24LCCSERVICE user guide will be useful to you.

Lastmanuals help download the user guide FUJITSU AOYR24LCCSERVICE.


Mode d'emploi FUJITSU AOYR24LCCSERVICE
Download
Manual abstract: user guide FUJITSU AOYR24LCCSERVICE

Detailed instructions for use are in the User's Guide.

[. . . ] 3 PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ADJUSTING THE DIRECTION OF AIR CIRCULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SWING OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Normal operation begins. About ECONOMY Operation At the maximum output, ECONOMY Operation is approximately 70% of normal air conditioner operation for cooling and heating. When ECONOMY operation is performed during the cooling mode, dehumidification is improved. This function is especially convenient when you want to remove the humidity in the room without significantly lowering the room temperature. During ECONOMY operation, the thermostat setting automatically changes according to the temperature to avoid Unnecessary cooling and heating for the most economical operation. If the room is not cooled(or heated) well during economy operation, select normal operation. Once air conditioner operation is stopped, normal operation begins when the indoor unit is turned on again. During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY operation even if ECONOMY operation is selected by pressing the ECONOMY operation button. HI-POWER OPERATION Begin Air Conditioner operation before performing this procedure. Open the Remote Control Unit lid. To Use the HI-POWER Operation Press the HI-POWER button(Fig. 5 e). The Indoor Unit's HI-POWER Indicator Lamp (orange) (Fig. 2 8) will light. HI-POWER operation begins. To Stop the HI-POWER Operation Press the HI-POWER button(Fig. 5 e) again. The Indoor Unit's HI-POWER Indicator Lamp(orange) (Fig. 2 8) will go out. However, HI-POWER operation will automatically stop under the following conditions. If SUPER QUIET Operations are selected during HI-POWER Operation, HI-POWER will be cancelled. If the air filters are unnecessarily pulled, they may be damaged or fall and cause personal injury. 1. Air filters come out The air filters automatically come out of the indoor unit under the open panel. At this time, the dust on the air filters is collected in the dust boxes (behind the open panel). Open panel 2. Air filter retract After the air filters come out, they automatically retract to their original positions in the Indoor Unit. When the auto filter maintenance is complete, the MAINTENANCE SIGN Indicator Lamp (red) (Fig. 2 4) on the Indoor Unit goes out. MAINTENANCE SIGN Indicator Lamp(red) flashes The MAINTENANCE SIGN Indicator Lamp (red) (Fig. 2 4) will flash during auto filter maintenance if the air filters are not Installed or are pulled. If this occurs during air conditioner operation, unplug the power supply cord from the Electrical outlet and follow procedures "Dust Box Maintenance" to install the air filters. Changing the FILTER MAINTENANCE Interval The filter maintenance interval can be changed. Some dust may be tough to clear away with Auto Filter Maintenance. In such a situation, please switch the Interval to 50H for more thorough cleaning. While cleaning, please place the remote control in stop mode (so that only the CLOCK and the time are displayed). Hold down the SET TIME button (Fig. 5 n) for at least 3 seconds. Switches from displaying the current time to displaying the interval, and begins blinking. Set the interval using the SET TIME button's and keys (Fig. 5 n). [. . . ] Poor Cooling performance: Did you adjust the room temperature settings (thermostat) correctly? In the case of Cooling operation, is a window allowing bright sunlight to enter?(Close the curtains. ) In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room? Is the unit set for SUPER QUIET operation? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FUJITSU AOYR24LCCSERVICE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FUJITSU AOYR24LCCSERVICE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag