User manual FURMAN PMPRO II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURMAN PMPRO II. We hope that this FURMAN PMPRO II user guide will be useful to you.

Lastmanuals help download the user guide FURMAN PMPRO II.


Mode d'emploi FURMAN PMPRO II
Download
Manual abstract: user guide FURMAN PMPRO II

Detailed instructions for use are in the User's Guide.

[. . . ] SERIES II 20 amp powER CondItIonERS SERIES II 20 amp powER CondItIonERS Furman Series II Features · SMP+ with extreme voltage shutdown · LiFT (Linear Filtering Technology) with zero ground contamination · Eight rear panel outlets and one front panel outlet · BNC connector on the rear panel allows you to attach any standard (12VAC 0. 5 amp) gooseneck lamp to illuminate the rear of your rack · 20 amp rating, with circuit breaker · Three year limited warranty pL-pRo Series II additional Features · Two retractable, long-life, low-heat LED light fixtures with dimmer control for rack illumination · Front panel meter to display incoming line voltage ranging from 90 to 128 volts pL-pRo d Series II additional Features · Two retractable, long-life, low-heat LED light fixtures with dimmer control for rack illumination · Laboratory precision Digital Voltmeter displays incoming line voltage (+/- 1. 5 VAC) pm-pRo Series II additional Features · Laboratory precision Digital Voltmeter displays incoming line voltage (+/- 1. 5 VAC) · True RMS Current Meter displays power draw (+/- 0. 5 amp) 1 SERIES II 20 amp powER CondItIonERS INTRODUCTION Thank you for purchasing a Furman Series II Power Conditioner, and Congratulations on your choice. The Series II power conditioners feature Furman's revolutionary Series MultiStage Protection Plus (SMP+) circuit, as well as our exclusive Linear Filtering Technology (LiFT). Together, these technologies comprise what is, without question, the world's most advanced and comprehensive transient voltage surge suppressor / conditioner. trusted over-voltage circuitry protects against all too frequent accidental connections to 208 or 240 VAC, by shutting off the incoming power until the over voltage condition is corrected. [For E versions: Furman's SMP+ clamps at 376 VpK, (266 VAC RMS. )] LiFT (Linear Filtering Technology) Unfortunately, traditional AC filter - conditioners have been designed for unrealistic laboratory conditions. [. . . ] A rear mounted BNC jack accepts any standard (12VAC 0. 5 amp) gooseneck lamp for rear rack illumination. The PM-PRO II has a master magnetic circuit breaker switch for the front and rear outlets that is protected from accidental disconnection by a hinged cover. The PM-PRO II also features a 10 foot, 12 gauge heavy-duty power cable. The PL-PRO II has a master magnetic circuit breaker switch for the front and rear outlets that is protected from accidental disconnection by a hinged cover. The PL-PRO II also features a 10 foot, 12 gauge heavy-duty power cable. PL-PRO D SERIES II 4 SERIES II 20 amp powER CondItIonERS O P E R AT I O N Retractable Rack Lights, Rear panel Lamp and dimmer Control: The PL-PRO II and PL-PRO D II utilize a dimmer control for the two retractable front panel light tubes. The dimmer knob controls the brightness of both light fixtures. Turn it clockwise to increase brightness; turn it counterclockwise to decrease brightness. When the lights are not in use, we recommend turning the dimmer fully counterclockwise to maximize the life of the LED's, however, this is not absolutely necessary. Whether the light tubes are retracted or flush with the front panel, there will be no appreciable heat regardless of dimmer setting due to the efficiency of our full light spectrum LED's. All Series II units feature a rear rack BNC socket which will accept any 12 VAC (0. 5A) gooseneck lamp assembly, (such as the Furman GN-LED or GN-I). Simply slide the BNC plug over the socket and rotate clockwise until the connector snaps into the locked position. The rear rack lamp can be powered on or off with the rear light power switch located on the far left of the front panel. The Series II's front panel LED lamps must be replaced by qualified Furman service personnel. multi-Segment LEd voltmeter: (pL-pRo II only) This three-color, 20-LED bargraph is an accurate, self checking AC voltmeter that continually measures normal voltages. The meter reads from 90 to 128 volts in 2 volt increments (PL-PRO E II: 180 to 256 volts, in 4 volt increments). The normal range voltages are indicated in green, with moderate and extremely high or low voltages in yellow and red respectively. The voltmeter provides three special flashing patterns to indicate abnormal conditions. Outlets ON ON ON ON ON ON ON OFF Multi-Segment LED Voltmeter Readings Mains Vltg. 80-90 90-104 106-108 110-120 122-124 126-128 130-140 Above 140 Voltage Status Low Marginal Low Medium Low Normal Medium High High High Marginal Extreme (Shutdown) Voltmeter Reading The LED beneath the 90V mark flashes Meter Reads in Low Red Meter Reads in Low Yellow Meter Reads in Green Meter Reads in High Yellow Meter Reads in High Red All Meter LEDs Flash Meter off--Extreme Voltage LED illuminates 5 SERIES II 20 amp powER CondItIonERS (1) If only the single leftmost (beneath the 90V mark ­ 180V for E version) LED flashes, the input voltage is marginally low. (2) If all of the LED's on the voltmeter flash, the input voltage is marginally high. Power to the PL-PRO's outlets will remain unless the incoming voltage rises above the Extreme Voltage Shutdown cutoff voltage (135 - 140 volts / 260 ­ 265 volts E version / 120 ­ 125 volts J version). (3) If none of the LED's on the voltmeter are lit, and the Extreme Voltages LED indicator is illuminated, then the PLPlus II has shut down power to its outlets because the input voltage is in a range considered extreme (in excess of 135 volts - 260 volts E version / 120 volts J version). digital Voltmeter: (pL-pRo d II and pm-pRo II only) Furman's laboratory precision AC digital voltmeter continually measures incoming voltages, within a typical tolerance of +/1. 5VAC. It should be noted that the voltage reading is incoming. [. . . ] If the Product does not conform to this Limited Warranty during the warranty period (as herein above specified), Purchaser shall notify Manufacturer in writing of the claimed defects. If the defects are of such type and nature as to be covered by this warranty, Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location. Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date; this is not necessary if the Warranty Registration was completed either via the mailed in warranty card or on-line website 8 SERIES II 20 amp powER CondItIonERS registration. Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the Purchaser of the product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURMAN PMPRO II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURMAN PMPRO II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag