User manual FURMAN PS8 R II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURMAN PS8 R II. We hope that this FURMAN PS8 R II user guide will be useful to you.

Lastmanuals help download the user guide FURMAN PS8 R II.


Mode d'emploi FURMAN PS8 R II
Download
Manual abstract: user guide FURMAN PS8 R II

Detailed instructions for use are in the User's Guide.

[. . . ] Additionally, Furman's trusted over-voltage circuitry protects against all too frequent accidental connections to 208 or 240 VAC, by shutting off the incoming power until the over voltage condition is corrected. [For E versions: Furman's SMP+ clamps at 376 VpK, (266 VAC RMS. )] 1 PS-8R II - POWER CONDITIONER / SEquENCER lIft (linear technology) f i lt e r i n g Traditional AC filter - conditioners have been designed for unrealistic laboratory conditions. Prior technologies, whether multiple pole filter or conventional series mode, could actually harm audio and video performance more than they help, due to the resonant peaking of their antiquated, non-linear designs. under certain conditions, these designs can actually add more than 10 dB of noise to the incoming AC line! [. . . ] Simply slide the BNC plug over the socket and rotate clockwise until the connector snaps into the locked position. The rear rack lamp can be powered on or off with the rear light power switch located on the far left of the front panel. The Series II's front panel lED lamps must be replaced by qualified Furman service personnel. reMote swItchIng (PS-8R II & PS-8R II E) In the most basic configuration, only two wires and an SPST switch are needed to initiate remote ON or OFF sequence. The switch may be either a momentary or maintained-contact type. If a third & fourth wire are used, an LED may also be installed at the remote end to indicate that the power is on. MAINTAINED VS. MOMENTARy CONTACT SWITCHING Maintained switches, such as most toggle switches and push-on/push-off switches (including the Furman RS-1), stay open until switched and then remain closed until switched again. Momentary switches, usually pushbutton types like the Furman RS-2, are normally open and stay closed only as long as the button is pressed. An on-off switch of either kind may be used to actuate the PS-8R II's remote operation. 4 PS-8R II - POWER CONDITIONER / SEquENCER Maintained switches are generally most convenient when there is only one remote location. When more than one switch location is required, momentary switches allow the sequence to be started from different locations. PS-8R II main circuit board has 5 pairs of terminals (PCB REV F and later) labeled as: JMP1 (REM TO +12V = OFF, DEFAuLT ), when the REM and +12V terminals are tied together, the PS-8R II will sequence OFF. JMP 1 2 3 4 REM TO +12V = OFF MOMENTARY MODE REM TO +12V = ON REM TO GND = ON JUMPER SETTING CHART jMP2 (MOMENTARy), when the REM and +12V JMp1) terminals are momentary tied together, the PS-8R Connection of the REM terminal to the +12V II will sequence ON or OFF. Disconnecting JMP3 (REM TO +12V = ON), when the REM and initiates an ON sequence. If the cable run is long, +12V terminals are tied together, the PS-8R II will it is recommended that the REM wire be tied to the PS-8R II's GND terminal during ON operation sequence ON. This will require the JMP4 (REM TO GND = ON), when the REM and use of a third conductor and a double-throw GND terminals are tied together, the PS-8R II will switch. sequence ON (Note: jMP1 must have a jumper reM to +12V = on (jumper plug installed on installed). Connection of the REM terminal to the +12V The PS-8R II unit comes factory-set for maintained terminal initiates an ON sequence. Disconnecting operation (jumper is installed on jMP1). reapplied) the "memory" state is OFF. This means the unit will be OFF even if the front panel on/off MuLTIPLE uNITS rocker switch is ON. It will stay off until sequenced More than one PS-8R II can be used to manage on by a momentary connection of the REM loads that exceed 15 amps. The power input terminal to +12V terminal. The sequence starts for each PS-8R II should come from a separate 15 amp AC circuit. To control multiple PS-8R on the rising edge of the signal. [. . . ] NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department, (707) 763-1010, Ext. Please display your RA Number prominently on the front of all packages. 8 PS-8R II - POWER CONDITIONER / SEquENCER r e l at e d p r o d u c t s The PS-8R II, along with other Furman AC power accessories, can be an integral part of a complete AC power control system. MP 15A, 20A, 30A Power Relays. PS-REL AC Relay RS-1 and RS-2 Remote System Control Panels other furman sequencer products: - PS-PRO II - PowerLink - ASD-120 - PowerPort - MP-15, MP-20q PS-8R II - POWER CONDITIONER / SEquENCER Maximum Load: PS-8R II: 15 amps (1800 watts at 120 VAC) PS-8R IIE: 10 amps (2300 watts at 230 VAC) SPECIFICA- Operating Voltage: 90 to 140 VAC ("E" versions 180 to 280 VAC) Over Voltage Shutdown: 140 VAC typically ("E" versions 260 VAC typically) Delay Interval: 5 seconds (adjustable with internal trimpot) Remote Switch: Momentary or maintained action. Remote Terminal: Screw terminals or Eurostyle pluggable Terminal Block, 2 for switch, 2 additional for optional LED (22 ga. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURMAN PS8 R II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURMAN PS8 R II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag