Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURMAN RVC7W. We hope that this FURMAN RVC7W user guide will be useful to you.
Lastmanuals help download the user guide FURMAN RVC7W.
Detailed instructions for use are in the User's Guide.
[. . . ] RVC-7W
Reference Video AC Power Conditioner 7 Amp In-Wall
IN T R O D U C T I ONS
Owner's Manual
FEATURES
Featuring Isolated Symmetrically Balanced Power and Narrow Bandwidth Technology
DESCRIPTION INSTALLATION SAFETY SPECS
RVC-7W
INTRODUCTION
FEATURES
DESCRIPTION
INSTALLATION
SAFETY
SPECS
INTRODUCTION
Thank you for purchasing Furman's Reference Series Video AC Power Conditioner tioner. The RVC-7W is a no-compromise, no-expense-spared design, with painstaking attention paid to every component. Further, this design was optimized to yield the maximum resolution from Plasma, LCD screens, and projectors while protecting them from transient voltage surges.
FEATURES
Isolated Symmetrically Balanced Narrow Bandwidth Technology dramatically reduces common mode and transverse AC line noise, typically in excess of 40dB at virtually all video frequencies up to 1 GHz. Maintenance free transient voltage surge suppression protects your valuable equipment, while virtually eliminating costly service calls. [. . . ] However, if the chassis is sticking out, or is recessed too far, an adjustment to the bracket position will be necessary. Both units have oval cutouts for depth adjustment. Re-drilling into the studs will only be necessary if the vertical measurements were so inaccurate as to make the RVC-7W hang at a noticeable angle clockwise or counter-clockwise. After the alignment has been checked and
INTRODUCTION
FEATURES
DESCRIPTION
INSTALLATION
SAFETY
RVC-7W
SPECS
adjusted, remove the chassis and install the cable clamps. We do not supply these, as they are very common at any hardware or electrical supply store, and individual installers will have their preferences as to model and manufacture. 7AMP 1O
OUTPUT: 120VAC 1O ( 60VAC LINE / 60VAC NEUTRAL REFERENCED TO OUTPUT GROUND) 60HZ. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. TO REDUCE RISK OF ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN AND MOISTURE. CIRCUIT COMMUN ISOLE DE LA MASSE A LA SORTIE. MEME SI LE COURANT A LA SORTIE EST MUNI DE PROTECTION GFI, NE JAMAIS TOUCHER LES FILS EXPOSES OU LES PARTIES EN METAL SANS TESTER POUR LA PRESENSE DE TENSIONS A. C. !ETL LISTED 3041249 CONFORMS TO ANSI/UL #1012 CERTIFIED TO CAN/ CSA E335-1/3E-94
L
N
-7-
RVC-7W
INTRODUCTION
FEATURES
DESCRIPTION
INSTALLATION
SAFETY
SPECS
circumstances. Consult the electrical code for your area. Now, connect the Plasma or projector's detachable A. C. cord to the GFI outlet (this is to make dressing through the front panel easier). Connect the ground strap from the front panel to the green 10-32 screw located on top of the input ground screw. Make sure this is secure, as it is for both safety and R. F. Also, take care to maintain the ground connection to the transformer. If the transformer's ground connection is compromised, the noise attenuation will suffer. Now, re-attach the front panel to the chassis. Go to the electrical panel and switch the power to the RVC-7W on. it is located next to the GFI outlet, and will be visible when you look into the larger rectangular cut-out in the front panel. If you are using the RVC-7W for a projector, you're finished! [. . . ] Furman does not warrant against damages or defects arising out of improper or abnormal use or handling of the product; against defects or damages arising from improper installation, against defects in products or components not manufactured by Furman, or against dam-
- 10 -
INTRODUCTION
FEATURES
DESCRIPTION
INSTALLATION
SAFETY
RVC-7W
SPECS
ages resulting from such non-Furman made products or components. This warranty shall be cancelable by Furman at its sole discretion if the product is modified in any way without written authorization from Furman. This warranty also does not apply to products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Furman. The sole and exclusive obligation of Furman shall be to repair or replace the defective product in the manner and for the period provided above. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURMAN RVC7W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURMAN RVC7W will begin.