Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO CI-35. We hope that this FURUNO CI-35 user guide will be useful to you.
Lastmanuals help download the user guide FURUNO CI-35.
Manual abstract: user guide FURUNO CI-35OPERATORS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200
All rights reserved.
Printed in Japan
FIRST EDITION : FEB. OME-72440 ( TATA ) CI-35/35H
*00080797601* *00080797601*
*00080797601*
*OME72440C00* *OME72440C00*
*OME72440C00*
SAFETY INSTRUCTIONS
"DANGER", "WARNING" and "CAUTION" notices appear throughout this manual. It is the responsibility of the operator of the equipment to read, understand and follow these notices. If you have any questions regarding these safety instructions, please contact a FURUNO agent or dealer.
DANGER WARNING CAUTION
This notice indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.
This notice indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This notice indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury, or property damage.
i
i
WARNING
Do not open the cover of the equipment. [. . . ] Relative tide movement of layer 2 based on surface layer. Relative tide movement of layer 3 based on surface layer. Nav-aided Mode (See page 3-6) Absolute tide movement of layer 1 (nav-tide) Absolute tide movement of layer 2 (nav-tide) Absolute tide movement of layer 3 (nav-tide)
Tide differentials between a specified reference layer and the other two layers. 3 . . . . . . .
YEL
PPL
YEL
PPL YEL
PPL
LBLU
PPL
LBLU
PPL
LBLU
Ref. layer (Left half)
Measuring layer (Right half)
3-10
TIDE VECTOR/COURSE PLOT SECTION
TIDE HISTORY Display
The CI-35/35H can hold last 24 tide samples collected at a time interval of 15 sec, 1 min, 5 min, 10 min, 30 min or 1 hour. The tide history presents variation of these tide information with a string of round marks. That is, distance from the graphic center to a mark represents tide speed at the sample time, and the direction from the center to a mark represents tide direction. The figure below can be interpreted that the tide has changed from SW to NE (opposite) direction. ` To call the tide history display, press the HISTORY key. The tide history of layers activated in MENU 1 - "LAYER n" are displayed. (The figure below shows history of only one layer. ) ` To restore normal tide vector display, press the
HISTORY
key again.
Tide history of layer 1 (last 24 samples)
N NW NE Present tide vector for layer 1
W
E
SW
Interval S
SE
You can select sampling time interval of tide history in MENU 1. (See page 4-2. )
Note: The CI-35/35H preserves the tide history data stored in the memory when the power is off.
3-11
TIDE VECTOR/COURSE PLOT SECTION
COURSE PLOT Display
The course plot display provides ship's track of last 20 minutes (200 points, one point sampled every 6 seconds). Event positions, stored by the ` Press the PLOT previous display.
COURCE EVENT
key, are also plotted with "+" marks.
key to call course plot display, and press the same key again to restore
N NW NE Present position
W
E Event marks Positions memorized by the
EVENT
key.
SW
SE
S
Ship's track (200 points max. )
` To change display range (distance range) of course plot, press the `DIST RANGE' in the RANGE menu. (See page 4-10. )
RANGE
key and set desired
` To clear event memory (marks), select `ERASE' in MENU 1 - "EVENT" and then press the
EVENT
key.
Note: ` Capacity of ship's position memory (for course plotting) is limited to 200 points. When the position memory is fully occupied, the oldest position is erased as new one comes in. ` Position memory will erased when the power is turned off. ` Sampling interval of ship's position is fixed to 6 seconds, and it can not be changed.
3-12
TIDE VECTOR/COURSE PLOT SECTION
TIDE EFFECT Display
The tide effect display is useful for estimating three-dimensional deformation of cast net by the effect of tides at different depths. Notice that display merely shows movements of layers; it does not show true net shape in the water.
Assume that you put drifting marks (virtual buoys) on the net at each layer below the vessel at an interval of six seconds.
Virtual buoys
Layer 1 (YEL) Layer 2 (PPL) Layer 3 (L-BLU)
As the marks move with the tides keeping the same speeds and directions, a series of marks makes a brief section shape of the net at the layer.
Layer 1 Virtual buoys Layer 2 Layer 3 Interval (6 sec) 100 points max. ( = 10 minutes)
In practice, a net does not sink immediately, because of various tensions and stresses placed on it. Thus, use the tide effect information only as a reference.
Buoy track of layer 1 (YEL) Buoy track of layer 2 (PPL) Buoy track of layer 3 (L-BLU)
Ship's course track (WHT) Cast mark (Start of tide effect plot)
` To start "tide effect plotting", press the
TIDE EFFECT
key. key again.
` To stop plotting and to clear traces, press the
TIDE EFFECT
3-13
TIDE VECTOR/COURSE PLOT SECTION Example of tide effect plotting
b
Tide of layer 2 Tide of layer 1 a Buoy track of layer 1 Buoy track of layer 2 d c
Display (Head-up)
Casting the first virtual buoys at point "a", vessel made 1/4 of a circle and reached point "b".
Current Ship's position always at screen center.
Assume that each buoy moves on each layer keeping the same speed and direction as at time of measurement. As time passes, the first buoys should move as lows:
d1 c1
` c c1 c2 c3: (Layer 1) ` d d1 d2 d3: (Layer 2)
d2
If the above situation is presented in the head-up mode, the display will change as shown right. [. . . ] SOUNDING FREQUENCY
130kHz approx.
7. DATA INPUT
1) HEADING DATA Clocked-serial (AD100) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ch 2) KEYING PULSE (for interference rejection) Current loop signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2ch 3) MISCELLANEOUSSerial (IEC1162, equivallent to NMEA0183) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ch Heading; Depth; W-temp; Date/time; ($--HDT/HDM/HCD/HCC) ($--DBS/DBT/DBK) ($--MTW) ($--ZDA/ZLZ/ZZU) --:any talker
8. DATA OUTPUT
1) LOG SIGNAL 200 pulses/nm 400 pulses/nm 2) EXTERNAL ALARM Contact signal, forward only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2ch (contact rating 0. 2A/30V max. ) TTL level, forward only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ch Contact rating 0. 2A/30V) Speaker output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1ch (800mW into 4 to 8 ohms) Serial (IEC1162, equivallent to NMEA0183). . . . . . . . . . . . . . . . . 1ch Speed/course($VDVTG/VBW/VHW) Set & drift ($VDVDR) Tide spd/dir ($VDVCD) Current ($VDCUR) Serial (Furuno CI-7000 format) for data recording . . . . . . . . 1ch (Date/time, ship's speed/course, tide speeds/directions, water
3) MISCELLANEOUS
AP-3
4) ANALOG SHIP SPEED
Current signal for Analog Display. -3. 33mA to 10. 0mA/-10kt to 30kt (Maximum load 400 ohms)
5) TRUE BEARING DATA
Clocked-serial (Furuno AD-100 format) . . . . . . . . . . . . . . . . . . . . . . . . 1ch
9. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO CI-35
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.