NAVIGATIONAL ECHO SOUNDER
FE-700
Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200
All rights reserved.
Printed in Japan
FIRST EDITION : JAN. OME-23660 ( TATA ) FE-700
*00080890802* *00080890802*
*00080890802*
*OME23660N10* *OME23660N10*
*OME23660N1*
SAFETY INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD
CAUTION
Do not power the equipment when the transducer is in air. The transducer may become damaged.
Do not open the equipment. Only qualified personnel should work inside the equipment. [. . . ] Default setting is IEC "1:98". When selecting the "1:98", DPT has max. range in use (See page 24).
Output IEC 61162-1 DPT Input RMA, RMC GLL, VTG ZDA, GGA RMA, RMC GLL, VTG ZDA, GGA
3. 3 System Menu 2
TIME ADJUST: Selects internal clock or external clock (UTC clock). For INTERNAL, set current day, month, year, hour, minute and second with [+], [-], [] or [] key. The setting clock appears and it counts upward.
SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL DAY 1 MONTH JAN YEAR 2001 (2100) HOUR 0 (023) MINUTE 0 (059) SECOND 0 (059) 01 JAN 2001 00:00:00 : To select item - +: To set option
Select other mode to exit. If EXTERNAL is selected, the screen changes as follows.
SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL 0:22:40
NMEA 0183
DBT (Ver. 1. 5) DBS (Ver. 1. 5) DPT (Ver. 2. 0)
ALARM SOUND: Selects audio alarm sound among 1, 2 or 3. 1: Continuous sound 2: Intermittent sound; 0. 5 s on and 0. 5 s off. 3: Intermittent sound; 1 s on and 1 s off. OS DATA: Selects own ship data display mode; DATA 1 or DATA 2. If a navigation device is not connected to the FE-700, select DATA 2. LANGUAGE: Currently English is only available.
: To select item - +: To set option Select other mode to exit.
TIME DIFFERENCE: Selects auto (UTC) or manual. Auto uses the time difference in ZDA (IEC 61162-1). In manual, it is necessary to enter the time difference in hours and minutes.
12
3. 4 System Menu 3
SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL TIME DIFF HOUR 0 (013) TIME DIFF MIN 0 (059) TIME DIFF SIGN - , + 0:22:40 : To select item - +: To set option Select other mode to exit.
RANGE 1- 8: Activates or deactivates specific range scales. Default ranges are 5, 10, 20, 40, 100, 200, 400, and 800 (meters). The ranges 20 m and 200 m can not be changed. Note: Ranges must be set in numerical order. For example, if range 1 is 5 m and range 3 is 20 m, range 2 should be between 6 and 19 m. Trend: The trend index shows the probable bottom shape over a specified time within 1-10 minutes. KEEL DISTANCE: Sets the vertical distance between the transducer and keel in meters, and has no affect on the display. This value (except zero) is used for "offset from transducer" in the sentence "DPT" of IEC 61162-1. Any value other than zero invalidates the draft value. When this value is zero (default setting), the draft value is valid.
13
4
ECHO QUALITY SETTING
4. 2 Transducer Setting
After installing the equipment, set the transducer as follows.
This chapter describes functions useful for improving echo sounding performance.
4. 1 Demonstration Display
The demonstration program shows how the FE-700 works.
1. [. . . ] Checksum
DBT Depth below transducer
$--DBT, x. x, f, x. x, M, x. x, F*hh<CR><LF> ||| | ||| | | | | | | +--------- 4 | | | | +--+----------- 3 | | +--+----------------- 2 +--+----------------------- 1 1. Checksum
26
GLL - Geographic position - latitude/longitude
$--GLL, llll. lll, a, yyyyy. yyy, a, hhmmss. ss, A, a*hh<CR><LF> || | | | ||| || | | | | | +------- 6 || | | | | +--------- 5 || | | | +----------- 4 || | | +---------------- 3 || +------+----------------------- 2 +---+----------------------------------- 1
1. Checksum NOTE Positioning system Mode indicator: A = Autonomous D = Differential E = Estimated (dead reckoning) M = Manual input S = Simulator N = Data not valid The Mode indicator field supplements the Status field. The Status field shall be set to V=invalid for all values of Operating Mode except for A=Autonomous and D=Differential. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FE-700
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.