User manual FURUNO FE-700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO FE-700. We hope that this FURUNO FE-700 user guide will be useful to you.

Lastmanuals help download the user guide FURUNO FE-700.


Mode d'emploi FURUNO FE-700
Download

You may also download the following manuals related to this product:

   FURUNO FE-700 SOFTWARE GUIDE (337 ko)
   FURUNO FE-700 OPERATORS MANUAL (999 ko)

Manual abstract: user guide FURUNO FE-700

Detailed instructions for use are in the User's Guide.

[. . . ] Back NAVIGATIONAL ECHO SOUNDER FE-700 Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : JAN. OME-23660 ( TATA ) FE-700 *00080890802* *00080890802* *00080890802* *OME23660N10* *OME23660N10* *OME23660N1* SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD CAUTION Do not power the equipment when the transducer is in air. The transducer may become damaged. Do not open the equipment. Only qualified personnel should work inside the equipment. [. . . ] Default setting is IEC "1:98". When selecting the "1:98", DPT has max. range in use (See page 24). Output IEC 61162-1 DPT Input RMA, RMC GLL, VTG ZDA, GGA RMA, RMC GLL, VTG ZDA, GGA 3. 3 System Menu 2 TIME ADJUST: Selects internal clock or external clock (UTC clock). For INTERNAL, set current day, month, year, hour, minute and second with [+], [-], [] or [] key. The setting clock appears and it counts upward. SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL DAY 1 MONTH JAN YEAR 2001 (2100) HOUR 0 (023) MINUTE 0 (059) SECOND 0 (059) 01 JAN 2001 00:00:00 : To select item - +: To set option Select other mode to exit. If EXTERNAL is selected, the screen changes as follows. SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL 0:22:40 NMEA 0183 DBT (Ver. 1. 5) DBS (Ver. 1. 5) DPT (Ver. 2. 0) ALARM SOUND: Selects audio alarm sound among 1, 2 or 3. 1: Continuous sound 2: Intermittent sound; 0. 5 s on and 0. 5 s off. 3: Intermittent sound; 1 s on and 1 s off. OS DATA: Selects own ship data display mode; DATA 1 or DATA 2. If a navigation device is not connected to the FE-700, select DATA 2. LANGUAGE: Currently English is only available. : To select item - +: To set option Select other mode to exit. TIME DIFFERENCE: Selects auto (UTC) or manual. Auto uses the time difference in ZDA (IEC 61162-1). In manual, it is necessary to enter the time difference in hours and minutes. 12 3. 4 System Menu 3 SYSTEM MENU 2 MENU SELECT 1 2 3 TIME ADJUST INTERNAL EXTERNAL TIME DIFFERENCE AUTO MANUAL TIME DIFF HOUR 0 (013) TIME DIFF MIN 0 (059) TIME DIFF SIGN - , + 0:22:40 : To select item - +: To set option Select other mode to exit. RANGE 1- 8: Activates or deactivates specific range scales. Default ranges are 5, 10, 20, 40, 100, 200, 400, and 800 (meters). The ranges 20 m and 200 m can not be changed. Note: Ranges must be set in numerical order. For example, if range 1 is 5 m and range 3 is 20 m, range 2 should be between 6 and 19 m. Trend: The trend index shows the probable bottom shape over a specified time within 1-10 minutes. KEEL DISTANCE: Sets the vertical distance between the transducer and keel in meters, and has no affect on the display. This value (except zero) is used for "offset from transducer" in the sentence "DPT" of IEC 61162-1. Any value other than zero invalidates the draft value. When this value is zero (default setting), the draft value is valid. 13 4 ECHO QUALITY SETTING 4. 2 Transducer Setting After installing the equipment, set the transducer as follows. This chapter describes functions useful for improving echo sounding performance. 4. 1 Demonstration Display The demonstration program shows how the FE-700 works. 1. [. . . ] Checksum DBT ­ Depth below transducer $--DBT, x. x, f, x. x, M, x. x, F*hh<CR><LF> ||| | ||| | | | | | | +--------- 4 | | | | +--+----------- 3 | | +--+----------------- 2 +--+----------------------- 1 1. Checksum 26 GLL - Geographic position - latitude/longitude $--GLL, llll. lll, a, yyyyy. yyy, a, hhmmss. ss, A, a*hh<CR><LF> || | | | ||| || | | | | | +------- 6 || | | | | +--------- 5 || | | | +----------- 4 || | | +---------------- 3 || +------+----------------------- 2 +---+----------------------------------- 1 1. Checksum NOTE Positioning system Mode indicator: A = Autonomous D = Differential E = Estimated (dead reckoning) M = Manual input S = Simulator N = Data not valid The Mode indicator field supplements the Status field. The Status field shall be set to V=invalid for all values of Operating Mode except for A=Autonomous and D=Differential. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FE-700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FE-700 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag