Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO IB-782. We hope that this FURUNO IB-782 user guide will be useful to you.
Lastmanuals help download the user guide FURUNO IB-782.
Manual abstract: user guide FURUNO IB-782OPERATORS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Continued use of the equipment can cause fire or electrical shock. Make sure no rain or water splash leaks into the equipment. Fire or electrical shock can result if water leaks in the equipment.
WARNING
Keep heater away from equipment. A heater can melt the equipment's power cord, which can cause fire or electrical shock. [. . . ] · Individual IDs may be assigned, for individual calling and communication log management. · Automatic call transfer
iv
SYSTEM CONFIGURATION
ANTENNA UNIT IB-180 IB-182
TEL or FAX COMMNUNICATION UNIT IB-282 JUNCTION BOX IB-313 MULTI-COMMUNICATION UNIT IB-782
TEL or FAX Max. 8 units
100-200 VAC
: Option
v
EQUIPMENT LIST
Name Multi-Communication Unit Installation Materials Type IB-782 -- 1 set · Power cable (3 m) · Tapping screw (4. 5, 4 pcs. ) Qty Remarks
vi
1. OPERATION
1. 1 Equipment Overview
The [POWER] switch is located on the rear panel. When the power is applied, the diagnostic test checks the equipment for proper operation, and the "Line LEDs" on the front panel light and go off in numerical order. After the diagnostic test is completed, only the power lamp lights. The 1A circuit protector protects the equipment from overcurrent.
FURUNO
M U LT I - C O M M U N I C AT I O N U N I T IB-782
P OW E R
SEND
LN0
LN1
LN2
LN3
LN4
LN5
LN6
LN7
LN8
Lights during automatic call forwarding. Lights when the power is on.
Front panel
P OW E R
100V-220VAC 50-60Hz
1A
Cable Gland
POWER connector POWER Switch Circuit Protector Ground Terminal
Rear panel
1
1. 2 Calling
Below is the procedure for how call a land subscriber, make a ship-to-ship call. Pick up the handset and dial "0" (number for connecting with Inmarsat services). Enter subscriber's complete number (vessel ID no. ), then press the [#] button.
Land subscriber
00
LES No. Service Country Area Code Code Code Subscriber's No.
# End Code
Ship-to-ship call
0
LES No.
0
Sea Area No. AOR-E: 871 POR: 872 IOR: 873 AOR-W: 874 Vessel ID No. (Inmarsat A or B)
# End Code
Service Code
3. Note 1: Dial number within 20 seconds after picking up the handset, or the call will be cancelled. Note 2: If you misdial, hang up the handset and dial again. In addition, dial each number within five seconds of the previous number, or the call will be cancelled.
1. 3 Receiving
To answer a call: 1. When a phone rings, pick up its handset and talk with the party. Hang up the handset upon completion of the call.
2
1. 4 Intercom
The intercom function is available when two or more telephones are connected to the IB-782. It allows communication between the telephones of the IB-782 and the telephones/handset of the communication unit IB-282 and between the telephones of the IB-782.
ANTENNA UNIT IB-182
TEL or FAX
Extension telephones connected to IB-782
HANDSET
TEL or FAX
TEL1
TEL2
TEL or FAX
TEL2
MULTI-COMMUNICATION TEL3 JUNCTION UNIT BOX IB-782 IB-313
TEL1
COMMUNICATION UNIT IB-282
TEL or FAX
TEL3 Max. 8 telephones
TEL or FAX
Connections for intercom feature
Calling IB-782's telephones
1. Pick up the receiver and listen for the dial tone. Dial party's extension number, then press the [#] button. [. . . ] · Locate the unit away from direct sunlight because heat can build up inside the cabinet. · Install the unit near the telephone or facsimile which is to be connected. · The mounting location should be stable and moderate in temperature and humidity. · Locate the unit away from areas subject to rain and water splash.
Mounting procedure
Fix the unit to the mounting location with four tapping screws (supplied).
Tapping Screw
IB -7
82
B4. 5 fixing
hole
MU
WE
L
-C TI
OM
MU
ND
NI
CA
TI
ON
UN
IT
LN 0
LN
1
LN
2
LN
3
LN
4
LN
5
LN
6
7 LN
LN
8
SE
FU
R
O UN
R
PO
IB-782
10
4. 2 Wiring
Follow the illustration below to wire the IB-782.
MULTI-COMMUNICATION UNIT IB-782
100V-220VAC 50-60Hz
TEL8 - TEL1 LN8-LN1
LINE LN0
POWER
1A
Ground Terminal
100-220 VAC Power Cable (supplied) To Communication Unit IB-282
CAUTION
Ground the equipment to prevent electrical shock and mutual interference.
TEL3 56
Junction Box IB-313
Local Supply (Use TTYCS-1 (Japan Industrial Standard) or equivalent. ) Armor Shield Conductor Vinyl sheath
Rosette MJ-2S
S =1. 25 mm 2 =1. 35 mm
Painting
TTYCS-1 sectional view
To Telephone (or FAX)
To Telephone (or FAX)
Modular Jack Cable (supplied)
Telephone
Facsimile
Telephone
Facsimile
Wiring
11
SPECIFICATIONS OF THE MULTI-COMMUNICATION UNIT IB-782
1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO IB-782
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO IB-782 will begin.