Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO MD-550. We hope that this FURUNO MD-550 user guide will be useful to you.
Lastmanuals help download the user guide FURUNO MD-550.
Manual abstract: user guide FURUNO MD-550OPERATORS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] MULTI-DISTRIBUTOR
MD-550
C
Yo u r L o c a l A g e n t/D e a le r 9-52, A shihara-cho, N ishinom iya, Japan Te l e p h o n e : Te l e f a x : 0 7 9 8 -6 5 -2 111 0798-65-4200
A ll rig h ts re s e rv e d .
Printed in Japan
FIRST
EDITIO N
:
N O V.
2001
PUB. OM E-44080
(T E N I)
M D-550
SAFETY INSTRUCTIONS
CAUTION
The mounting location should satisfy the following conditions: Sparate from radio transmitter, radar, direction finder (at least 3m). [. . . ] 1 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Fabrication of signal cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP-1 PACKING LIST OUTLINE DRAWING INTERCONNECTION DIAGRAM SCHEMATIC DIAGRAM
ii
System Configuration
12-24 VDC Distribute NMEA from one input to four output Input1 Distribute NMEA from one input to eight output Output1 Input1 Output2 Output3 Output4 Output5 Output6 Output7 Output8 Output1 Output2 Output3 Output4 Output5 Output6 Output7 Output8 When connecting by current loop, the standard FURUNO receive circuit (current limiter circuit: 470 , photocoupler: PC-400/900 are included) accepts one unit per output line. For connection of multiple equipment, contact a FURUNO agent or dealer for details.
Input2
Distribute AD-10 format Input1 Output1 Output2 Output3 Output4
Installation materials and Spare parts
Name Tapping screw Fuse Type 4X16 SUS304 FGMB 0. 5A 125V Code No. 000-802-080 000-114-994 Qty Remarks 4 CP14-06101 1 SP14-03001
1
Cables
Use the following cables (Japan Industrial Standard cables) or the equivalents.
Mounting
This unit has not power switch. If you do not connect the MD-550 to power switchboard or circuit breaker, install an external power switch (local supply), locating it near the MD-550.
DPYC-1. 5
Power cable
Armor Sheath = 11. 7 mm
Conductor S = 1. 5 mm 2 = 1. 56 mm
Current loop or RS-422
Jumpers
TTYCS-1 (Twisted pair cable) Armor Sheath = 10. 1 mm Shield Conductor S = 0. 75 mm 2 = 1. 11 mm
CR4 (POWER) LEDs CR5 (IN1) CR6 (IN2) Jumpers
21
6
5 14
TTYCS-1Q (Four core twisted)
AD-10 format
POWER LED: Lights when the power is supplied. Note: You can confirm working of output port (by LED) by connecting it to the other input port. (Refer to schematic diagram. )
Armor Sheath Shield = 11. 3 mm Conductor S = 0. 75 mm2 = 1. 11 mm
We recommend use of the following crimp-on lug.
CR5 Input1 Output1 Output2 Output3 Output4 Output5 Output6 Output7 Output8
FV1. 25-M3 (Code no. : 000-538-110) = 6. 6 mm 4. 0 mm = 3. 7 mm
CR6 Input2
Connection for confirming working of output port
2
Setting
Factory jumper settings are for current loop and "1 in 4 out". IN1 (OUT1-4) IN2 (OUT5-8) JP4 (#1-#2), JP1 (#1-#2), JP5 (#1-#2), Current loop JP2 (#1-#2), JP6 (#1-#2) JP3 (#1-#2) JP1 (#2-#3), JP4 (#2-#3), RS-422 JP2 (#2-#3), JP5 (#2-#3), JP3 (#2-#3) JP6 (#2-#3) JP7 1 in 4 out #1-#2 1 in 8 out #2-#3 Note1: Put short jumper into connector in same direction as before. [. . . ] 1. 5/2. 0 (RS-422 or current loop) Output: IEC 61162-1 (RS-422) 3. Transmission Rate Power Supply Coating Color 4800 bps to 38400 bps 12-24 VDC: 0. 25-0. 15 A 2. 5G7/2 Newtone No. 5
SP-1
E4408S01B [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO MD-550
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO MD-550 will begin.