User manual GAF FL6267-R2 UPDATED 2009

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAF FL6267-R2. We hope that this GAF FL6267-R2 user guide will be useful to you.

Lastmanuals help download the user guide GAF FL6267-R2.


Mode d'emploi GAF FL6267-R2
Download
Manual abstract: user guide GAF FL6267-R2UPDATED 2009

Detailed instructions for use are in the User's Guide.

[. . . ] Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P. E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity|ERD Evaluated" may be displayed in advertising literature. [. . . ] The product measures 13-13/16" wide supplied in 48" long sections Cobra® Snow Country AdvancedTM is a plastic, low-profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16" wide supplied in 48" long sections, and is supplied with 3" ring shank nails. Cobra® Ridge RunnerTM is a polypropylene plastic, low-profile attic ridge vent for use in shingle roof systems. The product measures 11½" wide supplied in 20 ft long rolls. Vented Ridge CrestTM is a plastic, high-profile attic vent with integral ridge cap shingles. The product measures 13" wide and 13 ¼" long. 4. 4 4. 5 4. 6 4. 7 5. LIMITATIONS: 5. 1 5. 2 This Evaluation Report is not for use in the HVHZ Minimum slopes are as follows: Product Cobra® Exhaust Vent Cobra® Rigid Vent 2TM Cobra® Rigid Vent 3TM Cobra® Snow CountryTM Cobra® Snow Country AdvancedTM Cobra® Ridge RunnerTM Vented Ridge CrestTM 5. 3 Minimum Slope 2:12 3:12 3:12 3:12 3:12 3:12 4:12 The maximum mean roof height for Cobra® Exhaust Vent, Cobra® Rigid Vent 2, Cobra® Rigid Vent 3, Cobra® Snow Country, Cobra® Snow Country Advanced and Cobra® Ridge Runner shall be 33 ft. The maximum design pressure for Vented Ridge CrestTM, as determined in accordance with FBC Chapter 16, shall be -75 psf. Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203. 2 and 2326. 3. 2, with not less than 50% of ventilation from soffit or cornice vents. When more than one level of roof ridge existing over a single attic space, use ridge vents only at the high ridge. 5. 4 5. 5 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506. 02. 06-R2 FL6267-R2 Revision 2: 04/21/2009 Page 3 of 8 6. INSTALLATION: 6. 1 GAF-ELK Roof Ventilation Products shall be installed in accordance with GAF-ELK published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. COBRA® EXHAUST VENT: Chalk a cut-line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch (for truss construction) or 3½-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends. Shorter lengths can be joined by caulking and butting the ends. Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nail with min. 2½-inch galvanized roofing nails at each corner and 10" o. c. Do not use excessive roof cement, as it may result in shingle blistering. Apply a bead of polyurethane roof sealant in the shape of a "C" to the underside of the entire perimeter of the cap shingles, and install cap shingles directly over the vent using Smart NailsTM (supplied with the vent). Do not use excessive roof cement, as it may result in shingle blistering. 6. 2 6. 2. 1 6. 2. 2 6. 2. 3 6. 2. 4 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506. 02. 06-R2 FL6267-R2 Revision 2: 04/21/2009 Page 4 of 8 6. 3 6. 3. 1 COBRA® RIGID VENT 2TM, RIGID VENT 3TM, SNOW COUNTRYTM AND SNOW COUNTRY ADVANCEDTM: Chalk a cut-line 7/8-inch off each side of the ridge and cut a slot along the apex of the roof measuring 1¾-inch (for truss construction) or 3¼-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. 6. 3. 2 Place, center and confirm the end-piece of ridge vent at each end of the slot. Proceed with attaching the other side of the vent. [. . . ] NOTE: The use of excess roofing cement can cause blistering of the asphalt shingle. Place the next piece snugly on top of the preceding piece, then slide forward until the tabs on the underside engage with the tabs on the rear of the first. Check the interlocking feature by gently trying to lift the front of the second piece. For increased wind resistance, follow instructions in section 6. 5. 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAF FL6267-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAF FL6267-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag