If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAI-TRONICS 12578-001. We hope that this GAI-TRONICS 12578-001 user guide will be useful to you.
Lastmanuals help download the user guide GAI-TRONICS 12578-001.
You may also download the following manuals related to this product:
GAI-TRONICS 12578-001 10-06 (200 ko)
Manual abstract: user guide GAI-TRONICS 12578-001DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] DS12578-001
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 12578-001 Monitored Input Module (MIM)
General Information
This data sheet applies to GAI-Tronics Model 12578-001 Monitored Input Module (MIM). The MIM is used to receive inputs from field devices, monitor the integrity of eight input lines for trouble conditions or contact activation, and report these conditions to the 69254 Series or 69440 Series Master Control Unit (MCU). The MIM is comprised of two components: the 69248-101 Central Processing Unit (CPU) PCBA and the 69251-101 Monitored-In-8 PCBA. [. . . ] DS12578-001 Page: 2 of 2
Maximum devices on input loop. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited (Mode 1) 1 (Mode 2) 1 (Mode 3) Unlimited (Mode 5) Input/output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power in Power out RS-485 in RS-485 out 8 field inputs Data communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485 RS485 termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On board when P2 jumper is installed End-of-line device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 k (Mode 1) 5. 1 k in series with 15 k across contact (Mode 2) 5. 1 k in series with 15 k across contact (Mode 3) None (Mode 5)
Field Inputs
Mode 1: Contact closure resistance (activated). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 k maximum Open Fault Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum 65 k Ground Fault Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 to ground Modes 2 and 3: Contact closure resistance (Mode 2: activated/ Mode 3: de-activated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 k maximum Open fault detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum 65 k Ground fault detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 to ground Wire-to-wire short fault detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 Mode 5: Contact closure resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 maximum Limitations: Cable limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] maximum
Environmental
Temperature range (operating/storage). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30° C to 70° C (-22° F to 158° F) Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% non-condensing relative humidity
Approval
CE Mark
f:\standard ioms - current release\data sheets\ds12578-001. doc 11/10 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS 12578-001 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS 12578-001 will begin.