User manual GAI-TRONICS 7325-106

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAI-TRONICS 7325-106. We hope that this GAI-TRONICS 7325-106 user guide will be useful to you.

Lastmanuals help download the user guide GAI-TRONICS 7325-106.


Mode d'emploi GAI-TRONICS 7325-106
Download

You may also download the following manuals related to this product:

   GAI-TRONICS 7325-106 DATASHEET (116 ko)

Manual abstract: user guide GAI-TRONICS 7325-106

Detailed instructions for use are in the User's Guide.

[. . . ] When installing an add-on station, consult the appropriate system layout diagrams. These figures, when used in conjunction with the station installation information and cable layout guide, should provide all the information necessary to install additional Page/Party stations. Enclosure Placement All GAI-Tronics Page/Party® units are wired in parallel. Good system layout design minimizes the cable required for each installation. GAI-Tronics multi-conductor cable, designed especially for this application, is recommended. [. . . ] After any muting changes are made, unpack the station amplifier and install. Mutual Muting In the event that feedback occurs within an area and repositioning of the system speakers does not help, mutual muting may be used to correct this problem. Perform the following steps to mutually mute adjacent amplifiers/handsets within a zone. Ensure that the purple lugged wire is connected to terminal 7 of TB1. Connect terminal TB1-7 of the handset station to TB1-7 of the station within the zone that is causing feedback. This is done by using the spare system wire (orange conductor) from within the system cable that runs between the stations. f:\standard ioms - current release\42004 instr. manuals\42004-370c. doc 11/10 Model 7325-106 Multi-Party Amplifier Enclosure Pub. Wiring Diagram f:\standard ioms - current release\42004 instr. manuals\42004-370c. doc 11/10 Model 7325-106 Multi-Party Amplifier Enclosure Pub. 42004-370C Page: 5 of 6 Maintenance Regular inspection and a good preventive maintenance program will increase the reliability of your GAI-Tronics station. The GAI-Tronics Field Service Department can formulate a service contract suited to your facility's specific need for preventive maintenance. In addition, the following procedure can be used to keep Page/Party® systems operating effectively. WARNING Before performing any of the following preventive maintenance steps, remove all power from the station. Remove the amplifier from the enclosure. Visually check the interior of the enclosure for signs of contamination such as dust, condensation or process liquid. 10440-002 Maintenance Cable, plug the amplifier into the connector in the enclosure. Check, and if necessary, adjust the amplifier to maximize performance. Reinstall the amplifier in the enclosure. Ensure that all gaskets and hardware are in place. Failure to install the gaskets, which also act as spacers, can result in damage to the connectors on the amplifiers and inside the enclosures and can cause system faults. It may become necessary to re-terminate some or all of the enclosures in a system. If so, strip the wires back to clean copper and connect only one wire to each connector to allow for easier future troubleshooting. Troubleshooting The following table lists some hints to aid technicians in troubleshooting. Problem Solution Feedback occurs only during page. 1. If a speaker is close to the station, try using the muting feature in the amplifier enclosure at the terminal blocks. [. . . ] manuals\42004-370c. doc 11/10 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller's goods prove to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose specified and agreed upon, and (b) Buyer's claim is made within the warranty period set forth above, Buyer may return such goods to GAI-Tronics' nearest depot repair facility, freight prepaid, at which time they will be repaired or replaced, at Seller's option, without charge to Buyer. Repair or replacement shall be Buyer's sole and exclusive remedy. The warranty period on any repaired or replacement equipment shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original equipment was shipped. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS 7325-106

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS 7325-106 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag