User manual GAI-TRONICS IPE2500A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GAI-TRONICS IPE2500A. We hope that this GAI-TRONICS IPE2500A user guide will be useful to you.

Lastmanuals help download the user guide GAI-TRONICS IPE2500A.


Mode d'emploi GAI-TRONICS IPE2500A
Download
Manual abstract: user guide GAI-TRONICS IPE2500A

Detailed instructions for use are in the User's Guide.

[. . . ] 43004-008F GAI-TRONICS® CORPORATION A HUBBELL COMPANY Model IPE2500A and IPE2500A-MLS Paging Encoder/Desktop Controller User and Installation Manual GAI-Tronics Corporation 400 E. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW. GAI-TRONICS. COM FOR PRODUCT LITERATURE AND MANUALS CONFIDENTIALITY NOTICE This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. [. . . ] In this example, the A tone number entered by the console operator is 4, which corresponds to 1251. 4 Hz. The second digit of the number from chart B (2 in this example) also corresponds to a number under Tone Group Frequency Chart Group #, and indicates which row of frequencies on chart will be used for the B tone. In this example, the B tone number entered by the console operator is 3, which corresponds to 669. 9 Hz. The previous example involves the console operator being required to enter two digits from the keypad (programming the number of 2-Tone digits accepted from the user on the selected channel to 2). However, if all three digits were required from the console operator (programming the number of 2-Tone digits accepted from the user on the selected channel to 3), the procedure for finding the frequencies from the Tone Group Frequency Chart would be the same, except that the most significant digit of the prefix would be the first digit entered from the keypad. If no digits were required from the operator (programming the number of 2-Tone digits accepted from the user on the selected channel to 0) both the A and B tone frequencies would be predetermined through programming and the same tone sequence would be sent every time a 2-Tone page is generated on this particular channel. Group Call A group call occurs when both tones of a 2-Tone paging sequence are the same frequency. If the console is programmed to allow 8-second group calls on a particular channel, then whenever a paging sequence is generated that consists of two tones of the same frequency, the page consists of an 8-second burst of that tone frequency. However, 8-second group calls do not apply when the GE code plan has been selected. In the GE system, a "diagonal" tone of 742. 5 Hz is inserted in place of the first tone if that tone is the same as the second tone. 06/10 26 IPE2500A and IPE2500A-MLS Paging Encoder/Desktop Controller Operation Example 2 Suppose the number of 2-Tone keypad digits accepted from the user on the selected channel is 2 and the GE code plan has been selected. Therefore, if the operator entered 55 as the paging digits and pressed the TRANSMIT button, the console would send the 2-Tone sequence A = 742. 5 Hz, B = 907. 5 Hz. This would alert a pager with a GE capcode of 455. Important NOTE: The 1st digit indicates Chart A Group # Source for the A tone, and the 2nd digit indicates Chart A Group # Source for B Tone. Code Plans Table Code Plan Gen Enc Gen Enc Modified MSD Digit of 3-Digit Capcode 0 42 42 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A AA 99 1 11 11 11 11 11 11 11 11 11 11 11 11 23 23 23 24 24 25 34 34 35 46 77 BA AA 2 22 22 22 22 22 22 13 13 13 14 14 15 22 22 22 22 22 22 43 43 53 64 88 BB BB 3 12 33 33 12 12 12 33 33 33 41 41 51 33 33 33 42 42 52 33 33 33 56 99 AB DD 4 44 44 12 44 15 21 44 31 31 44 44 16 44 32 32 44 44 26 44 44 36 44 78 CC 9D 5 55 55 13 14 55 16 31 55 16 55 16 55 32 55 26 55 26 55 55 36 55 55 79 CA D9 6 21 66 21 21 21 66 14 15 66 15 66 66 24 25 66 25 66 66 35 66 66 66 87 CB AD 7 45 DD 31 41 51 61 41 51 61 45 61 61 42 52 62 45 62 62 45 63 63 45 97 AC DA 8 54 EE 23 24 25 26 34 35 36 54 46 56 34 35 36 54 46 56 54 46 56 54 89 BC BD 9 24 FF 32 42 52 62 43 52 63 51 64 65 43 53 63 52 64 65 53 64 65 65 98 N/A DB B C D E F G H J K L M N P Q R S T U V W Y GE SP 27 06/10 Operation IPE2500A and IPE2500A-MLS Paging Encoder/Desktop Controller Tone Group Frequency Chart The chart below cross-references the 2-Tone Paging Code to the frequency in Hz. Tone Group # Group # 0 330. 5 569. 1 1092. 4 321. 7 553. 9 1122. 5 358. 9 371. 5 346. 7 682. 5 652. 5 667. 5 643. 0 1472. 9 1930. 2 1 349. 0 600. 9 288. 5 339. 6 584. 8 1153. 4 398. 1 412. 1 384. 6 592. 5 607. 5 712. 5 910. 0 1513. 5 1989. 0 2 368. 5 634. 5 296. 5 358. 6 617. 4 1185. 2 441. 6 457. 1 426. 6 757. 5 787. 5 772. 5 1036. 0 1555. 2 2043. 8 3 389. 0 669. 9 304. 7 378. 6 651. 9 1217. 8 489. 8 507. 0 473. 2 802. 5 832. 5 817. 5 1082. 0 1598. 0 2094. 5 4 410. 8 707. 3 313. 0 399. 8 688. 3 1251. 4 543. 3 562. 3 524. 8 847. 5 877. 5 862. 5 1130. 0 1642. 0 2155. 6 5 433. 7 746. 8 953. 7 422. 1 726. 8 1285. 8 602. 6 623. 7 582. 1 892. 5 922. 5 907. 5 1287. 0 1687. 2 2212. 2 6 457. 9 788. 5 979. 9 445. 7 767. 4 1321. 2 668. 3 691. 8 645. 7 937. 5 967. 5 952. 5 1465. 0 1733. 7 2271. 7 7 483. 5 832. 5 1006. 9 470. 5 810. 2 1357. 6 741. 3 767. 4 716. 1 547. 5 517. 5 532. 5 1820. 0 1781. 5 2334. 6 8 510. 5 879. 0 1034. 7 496. 8 855. 5 1395. 0 822. 2 851. 1 794. 3 727. 5 562. 5 577. 5 1985. 0 1830. 5 2401. 0 9 539. 0 928. 1 1063. 2 524. 6 903. 2 1433. 4 912. 0 944. 1 881. 0 637. 5 697. 5 622. 5 2688. 0 1881. 0 2468. 2 1 2 3 4 5 6 A B Z GE(A) GE(B) GE(C) Plectron 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 06/10 28 IPE2500A and IPE2500A-MLS Paging Encoder/Desktop Controller Operation Plectron Paging The Plectron paging feature requires a 4-digit prefix (capcode). Like 2-Tone paging, the capcode and code plan will determine at what frequency the paging tones will be transmitted. Plectron paging uses the Plectron Code Plan Chart and Plectron Tone Group/Frequency Chart. Refer to the example below and the tables to determine the capcodes you need. Plectron Paging Example Suppose the number of Plectron keypad digits accepted from the user on the selected channel is 0 and the capcode has been programmed to 3456. The A tone length is 1 second and the B tone length is 2 seconds. If the console operator were to press the TRANSMIT button, the console would send an A tone of 330. 5 Hz for 1 second, and then a B tone of 564. 7 Hz for 2 seconds. The frequencies for the A and B tones are determined from the charts that follow, according to the following procedure: 1. Locate the first two digits of the prefix (3 and 4 in this example) on the Plectron Page Code Plan Chart below. In the column beneath this two-digit number, there are two P numbers (P5 and P6 in this example) that correspond to tone groups on Plectron Page Code Plan Chart. Using the P number for the third digit of the prefix, determine the correct tone group from the Plectron Tone Group/Frequency Chart on page 30. [. . . ] No, low, or distorted transmit audio. If the receive audio is derived from a detector or discriminator, continuous noise is heard unless the receiving unit has an internal squelch circuit. Ensure that the microphone sensitivity is properly adjusted for the microphone in use. Ensure that the line output level is properly adjusted. Ensure that the microphone compressor is enabled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS IPE2500A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS IPE2500A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag