User manual GE INTERLOGIX SIMON 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GE INTERLOGIX SIMON 3. We hope that this GE INTERLOGIX SIMON 3 user guide will be useful to you.

Lastmanuals help download the user guide GE INTERLOGIX SIMON 3.


Mode d'emploi GE INTERLOGIX SIMON 3
Download
Manual abstract: user guide GE INTERLOGIX SIMON 3

Detailed instructions for use are in the User's Guide.

[. . . ] ) ZZZ*(, QWHUORJL[6HFXULW\FRP 466-1873 Rev F September 2002 *( , QWHUORJL[ Part No: 60-875 60-910 (Not investigated for use by UL) Doors & Motion Windows Sensors System Status HOME SECURITY Arm 1/2 3/4 Disarm 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor On Off HOME CONTROL Bypass Lights EMERGENCY FIRE POLICE AUX Test Weekly Simon Security System Installation Instructions FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix Inc. can void the user's authority to operate the equipment. FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. [. . . ] To turn off Alarm Cancel Report, press: Delete--Option #--18--DONE. Option 19: RF Timeout (Default = 12 hours) Determines the time period the panel must receive at least one supervisory signal from learned sensors before identifying a sensor failure and sounding trouble beeps. Any sensor failure is reported immediately and again at the supervisory time (Option 72: Supervisory Time). Note Setting this feature to 2 hours (02) may cause false reports. For UL 985 and 1635 listed systems, RF Timeout must be set to 4 hours (04). For UL 1023 listed systems, RF Timeout must be set to 24 hours (24). The timeout can be set from 02-24 hours. To change RF Timeout, press: Add--Option #--19--02 - 24--DONE. To reset RF Timeout (return to default), press: Delete--Option #--19--DONE. Option 20: Manual Phone Test (Default = on) Determines whether the user can perform a manual phone test to verify communication to a central station/pager (on), or not (off). To turn on Manual Phone Test, press: Add--Option #--20--DONE. 25 Simon Security System To turn off Manual Phone Test, press: Delete--Option #--20--DONE. Option 21: Opening Reports (Default = off) Determines whether the panel sends opening reports to a central station or pager whenever the system is disarmed (on), or not (off). To turn on Opening Reports, press: Add--Option #--21--DONE. To turn off Opening Reports, press: Delete--Option #--21--DONE. Option 22: Closing Reports (Default = off) Determines whether the panel sends closing reports to a central station or pager whenever the system is armed (on), or not (off). To turn on Closing Reports, press: Add--Option #--22--DONE. To turn off Closing Reports, press: Delete--Option #--22--DONE. Option 23: Force Armed Report (Default = off) Determines whether the panel sends a force armed report to a central station or pager if the user bypasses protesting sensors (indirect bypass) when arming the system (on), or not (off). To turn on Force Armed Report, press: Add--Option #--23--DONE. To turn off Force Armed Report, press: Delete--Option #--23--DONE. Option 24: AC Power Failure Report (Default = off) Determines whether the panel sends AC power failure reports to a central station or pager after the programmed time expires (on), or not (off). When the panel is without AC power for 30 seconds, the panel LEDs turn off. When the panel is without AC power for the programmed time, an AC power failure is reported. The panel reports an AC power restoral when AC power returns to the panel. Note For UL listed systems, AC Power Failure must be set to 15 minutes. The time can be set from 5-254 minutes. To turn on AC Power Failure Report, press: Add--Option #--24--005 - 254--DONE. To turn off AC Power Failure Report, press: Delete--Option #--24--DONE. Option 25: CPU Low Battery Report (Default = on) Determines whether the panel sends a low CPU battery report to the central station when the panel backup battery voltage drops below 5. 4 volts (on), or not (off). To turn on CPU Low Battery Report, press: Add--Option #--25--DONE. To turn off CPU Low Battery Report, press: Note For UL listed systems, CPU Low Battery Report must be on. Simon Security System 26 Delete--Option #--25--DONE. Option 26: Fail to Communicate (Default = on) Determines whether the panel and interior sirens sound trouble beeps if it is unable to successfully send a report to a central station or pager (on), or not (off). To turn on Fail to Communicate, press: Add--Option #--26--DONE. To turn off Fail to Communicate, press: Delete--Option #--26--DONE. Note For UL listed systems, Fail to Communicate must be on. Option 27: Ring/Hang/Ring (Default = 1) Determines when the panel answers a remote phone access or Toolbox call. [. . . ] No report. * 25 Local Special Chime: Notify the user when a door is opened. Sounds emit from a local annunciator. * Direct Bypass and Unbypass when no Special Motion Chime sensors are in the security system. No report 26 Fire: 24 hour fire, rate-of-rise heat, and smoke sensors. 27 Lamp control or other customer feature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE INTERLOGIX SIMON 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GE INTERLOGIX SIMON 3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag