User manual GE PSB48LGRBV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GE PSB48LGRBV. We hope that this GE PSB48LGRBV user guide will be useful to you.

Lastmanuals help download the user guide GE PSB48LGRBV.


Mode d'emploi GE PSB48LGRBV
Download
Manual abstract: user guide GE PSB48LGRBV

Detailed instructions for use are in the User's Guide.

[. . . ] This generator system is designed and intended only for use as an optional home standby system that provides an alternate source of electric power and to serve loads such as heating, refrigeration systems, and communication systems that, when stopped during any power outage, could cause discomfort or inconvenience. Save these instructions for future reference. This generator requires professional installation before use. You never have to look far to find support and service for your generator. [. . . ] DO NOT lift unit by roof as damage to generator will occur. Insert pipes through the lifting holes (D) located near the unit's base. Youmayalsolifttheunitusinga"hookandhoist"method attached to the lifting pipes, provided that you use a spreader bar to ensure that the chains or cables DO NOT touch the generator's roof. After unit is in place, fill the lifting holes with the supplied lifting hole plugs. Retouch any chipped paint with supplied touch-up paint. The home generator is equipped with an enclosure that has several access doors. The doors are named for a significant component located behind them, as follows: A Control Panel door (shipped loose - to be attached by installer) B Fuel Inlet Port (shown for reference) C Oil Drain door D Exhaust Port (cover to be attached by installer) E Oil Fill door WarninG Contact with muffler area could cause burns resulting in serious injury. DO NOT touch hot parts and AVOID hot exhaust gases. Allow equipment to cool before touching. The entire flexible gaseous pipe must be visible for periodic inspection and must not be concealed within nor contact nor run through any wall, floor, or partition. Pipingshouldbeprotectedfromphysicaldamage where it passes through flower beds, shrub beds, and other cultivated areas where damage could occur. The remote LED will turn on and off in a series of blinks if certain faults are detected in the generator. A single-phase, three-wire AC connection system is used in the home generator. The stator assembly consists of a pair of stationary windings with two leads brought out of each winding. the junction of leads 22 and 33 forms the neutral lead , as shown schematically and as a wiring diagram. A complete schematic and wiring diagram can be found later in this manual. Neutral is not bonded to ground at generator. The "240VUtility"leadsdeliverpowertothegenerator'scircuit board, optional battery warmer and optional oil warmer. When power on these leads is lost, the generator will start. Using provided 2 pin connector plug and installer-supplied minimum 300V, 14 AWG copper wire, connect each control circuit terminal in the generator to the two-amp fuse terminals in the automatic transfer switch. When making connections, obey wire type and torque specifications printed on the circuit breaker and neutral/ ground connector. (Units with an ACCM II or later control board only) Using #18 AWG twisted pair conductors, no greater than 200 ft in length, connect Tx Rx and Tx Rx Ground from the generator control panel (a) to the GND and T/R on the transfer switch control board (B). [. . . ] During this exercise period, the unit runs for approximately 20 minutes and then shuts down. Electrical load transfer DOES NOT occur during the exercise cycle (unless an utility power outage occurs during the cycle). The specific day and the specific time of day this button is pressed is programmed into the control board memory. This date and time is then used to automatically initiate the system exercise cycle. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE PSB48LGRBV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GE PSB48LGRBV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag