Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GENERAL ELECTRIC HGS. We hope that this GENERAL ELECTRIC HGS user guide will be useful to you.
Lastmanuals help download the user guide GENERAL ELECTRIC HGS.
Manual abstract: user guide GENERAL ELECTRIC HGSINSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] Thank you for purchasing this quality-built GE home generator. We're pleased that you've placed your confidence in the GE brand. When operated and maintained according to the instructions in the operator's manual, your home generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with residential generator systems and how to avoid them. [. . . ] Consider the following factors when planning the fuel supply system installaton: · Aminimumofoneaccessible, approvedmanual shutoff valve shall be installed in the fuel supply line within 6 ft (1. A union or flanged connection shall be provided downstream from this valve to permit removal of controls. Naturalgasfuelsupplypressureatthegenerator's fuel inlet port should be between 5 to 7 inches of water (in. ) at full load with all gas appliances turned on and operating. ) at full load with all gas appliances turned on and operating. Note: Where local conditions include earthquake, tornado, unstable ground, or flood hazards, special consideration shall be given to increase strength and flexibility of piping supports and connections. The generator has been factory set to run on natural gas. If you need to change from natural gas to LP gas, the unit will need to be reconfigured, as described in Fuel Conversion. Amanualfuelshut-offvalvelocatedoutsidethe building, just before the generator unit. Wheretheformationofhydratesoriceisknownto occur, piping should be protected against freezing. The termination of hard piping should include a sediment trap where condensate is not likely to freeze. When the initial test runs are completed, the manometer is removed and the port is plugged. A typical final fuel connection assembly is shown here, where (a) is the fuel supply and (B) goes to the home generator. The manometer port permits temporary installation of a manometer to ensure that the engine receives the correct fuel pressure to operate efficiently throughout its operating range. For example, NFPA 54 National Fuel Gas Code, 2006 (Item #: 320-6031-06) is a common resource. The installer should consider the specific gravity of gas and compensate for a nominal amount of restriction from bends, fittings, etc. If an unusual number of fittings, bends, or other restrictions are used, refer to federal and local codes for guidance. Estimated fuel supply requirements at half and full load for natural gas and LP vapor fuels are shown here. C = Cubic feet per hour B = BTU's per hour Normal atmospheric state Boiling Point (in °f): initial end heating Value: Btu per gallon (net LhV*) Btu per gallon (gross**) cubic feet (gas) Density*** Weight octane number: research Motor Gross heat value does not consider heat lost in the form of water during combustion. *** Density is given in "Cubic Feet of Gas per Gallon of Liquid". Weight is given in "Pounds per Gallon of Liquid". Low Voltage connections to signal fault contacts, transfer switch communication, remote LED and auxiliary 12VDC power are made via a removable ten-pole connector plug. [. . . ] Should that voltage drop below a preset level, control board action will signal the engine to crank and start. When utility source voltage is restored above a preset voltage level, the engine is signaled to shut down. The actual system operation is not adjustable and is sequenced by sensors and timers on the control board, as follows: utility Voltage Dropout sensor · When that voltage is restored above 80 percent of the nominal source voltage, a time delay starts timing and the engine will go to engine cool-down. engine cool-down timer · Whentheloadistransferredbacktotheutilitypower source, the engine cool-down timer starts timing. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GENERAL ELECTRIC HGS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GENERAL ELECTRIC HGS will begin.