Manual abstract: user guide GEORG FISCHER EA30

Detailed instructions for use are in the User's Guide.

[. . . ] Any work done on the actuator may only be carried out by authorized and trained personnel. These products are according to the Machine Guidelines 98/37/EG (ancient 89/392/EWG), not regarded as machines; they are, however, built into installations which are regarded as machines. Note We distinctly emphasize that operation is prohibited until it has been confirmed that the machine (plant) into which the products have been built corresponds to the conditions of the EC Machine Guidelines 98/37/EG (ancient 89/392/EWG). 44 GEORGE FISCHER . . . 2. Design of the actuator The standard version of the electrical actuator EA 30 consists of the following elements: spurwheel gear, DC motor, power supply board as well as components for limit positioning. [. . . ] Limit switch positions Switch S1 opens at <open> position Switch S2 opens at <closed> position (see diagram in the margin) Procedure Both switching cams S1 and S2 are to be adjusted so that the actuating angle is less than 90°). Drive the actuator until one limit switch, either <closed> or <open> is operated. The end positions can be adjusted by moving the switching cams, as the actuator follows them. ¼ For George Fischer ball valves an exact 90°) rotation should be set. ¼ For George Fischer butterfly valves the <closed> position should be adjusted according to the following directions. S2 S1 GEORGE FISCHER . . . 49 G/2 a Setting the <closed> position in actuators At the <closed> position in butterfly valves the disk is not exactly vertical to the pipe axis. Deviation values can be taken from the following table. open a­b b DN mm 65 80 d mm 75 90 a­b mm 4 4 50 GEORGE FISCHER . . . 5. Specifications 5. 1 Actuator unit Nominal voltage 5 / 230 V, 50­60 Hz (switchable) 24 V = / 24 V, 50­60 Hz 48 V, 50­60 Hz on request @2 W IP 65 in accordance with DIN 40050 @00% at 25 °C / 70% at 50 °C, 20 min Dependent on current and time (automatic reset) 1) Cable plug 3 P+E in accordance with DIN 43650 additional cable connections PG 270°, set to 90° 25 Nm 50 Nm ­@0° to +50 °C 2) 0­98%, non-condensing PP fiberglass reinforced external screws rust-proof visual, integrated Power consumption Protection Duty cycle Overload protection Electric connection Control time Angle of operation Continuous torque Peak torque Operating temperature Permissible humidity Body material Position indicator 1) The overload protection is designed to protect both motor and power supply board. If the overload protection device has triggered, it will reset automatically when the unit has cooled down sufficiently and the actuator will operate again. For temperatures below ­@0 °C the heating element Nr. @43 should be installed (see Item 6. 5). 2) GEORGE FISCHER . . . 51 5. 2 Block Diagram input voltage selection 230 V 1@5 V Closed 2 N S2 power supply overload protection Open L 1 S1 M N 230 V 1@5 V reversing circuit 5. 3 Dimensions 72 56. 4 159 63. 7 185 120. 7 61 146 85 15 52 GEORGE FISCHER . . . 6. Assembly and Connection of Modular Components The electrical actuator EA 30 is equipped with fastening points which allow for additional modular components to be mounted. The configuration of these points is described under Section 2. The electrical connection is made by means of a second cable plug or a threaded cable joint (depending on the number of connecting wires). The respective kits are prepared for installation, the electric cables are cut to size and package accordingly. In the following sections, the corresponding assembly points and the wiring are illustrated. GEORGE FISCHER . . . 53 6. 1 Mechanical limit switches Description Kit with 2 additional auxiliary switches Kit with 4 additional auxiliary switches Kit with 2 additional auxiliary switches with gold contacts 1 2 1 Additional switching cams 2 Limit switch S5, S6 or S5 to S8 Technical Data 250 V , @0 A 250 V , @0 A 4­30 V = 1­@00 mA Code @99 @90 @38 @99 @90 @39 @99 @90 @49 Wiring diagram Nr. 199 190 139 S8 S7 S6 S5 Wiring diagram Nr. . 149 M S1 S2 S6 14 2 S5 14 2 M S1 S2 14 2 14 2 14 2 14 2 black white black red FED 654N21 65 FED 4N2 1 1 3 2 1 B A DC AC L1 N PE B A DC AC L1 N PE 54 GEORGE FISCHER . . . 6. 2 Inductive limit switches The mechanical installation of these switches is identical to those under 6. 1. An additional metal part must be mounted so that the active surface of the inductive switch can be activated. [. . . ] Spare parts list 1 2 3 Description Unit plug, complete Gear box and motor (irrespective of voltage) Power supply unit 1@5 / 230 V / 50­60 Hz 24 V = / 48 V Electrical Actuator, complete 1@5 / 230 V / 50­60 Hz 24 V = / Cover set consisting of: 1 cover 1 clamp 1 showcase inspection glass 1 seal 1 O-Ring 5 PT-screws Sealing set consisting of: 4 screw 1 sealing ring 5 PT screw 4 spring washer 1 shaft seal 1 O-Ring Limit switch set consisting of: 2 limit switches 4 screws 4 washers Position indicator Code @98 000 147 @98 800 310 @98 150 586 @98 150 587 @98 150 588 @98 150 711 @98 150 710 @98 000 138 @98 000 139 @98 000 140 @98 800 899 3 2 1 Butterfly Valve Type 035 d mm 75 90 DN mm 65 80 Intermediate housing Intermediate housing with manual override without manual inch override 2 1/2 198 000 120 198 000 126 3 198 000 121 198 000 127 Ball Valve Type 108 d mm 75 90 DN mm 65 80 Intermediate housing with manual override inch 2 1/2 198 000 132 3 198 000 133 Warning: Beware of turning bolt in the intermediate housing with manual override GEORGE FISCHER . . . 60 GEORG FISCHER . . . A AUS B/L CH CHINA D Georg Fischer Rohrleitungssysteme GmbH, Sandgasse 16, 3130 Herzogenburg Tel. +43(0)2782/8 56 43-0, Fax +43(0)2782/8 51 56, e-mail: office@georgfischer. at George Fischer Pty. Ltd. , 4 Jacks Road, South Oakleigh, Victoria 3¢67 Tel. +48(0)22/638 91 39, Fax +48(0)22/638 00 94 Georg Fischer AB, Box 113, 12523 Älvsjö-Stockholm, Tel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GEORG FISCHER EA30

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GEORG FISCHER EA30 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag